Barrow County · Ordenanza de zonificación
Part II - CODE OF ORDINANCES / Chapter 89 - UNIFIED DEVELOPMENT CODE / Article XV - DESTINATION 211 DISTRICT / Division 4 - BUILDING DESIGN
Sec. 89-1523. Storefront treatment.
Sobre este texto
- As published by Municode, retrieved 2026-11-23
- The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.
Las notas de arriba, el texto de la sección y su línea de historia se muestran en inglés, tal como los publica la fuente y como los da el corpus.
(a) New non-residential principal buildings and vertical mixed-use structures shall be designed in accordance with the "storefront treatment" specifications below:
(1) Storefront treatment is an architectural treatment that must be provided on the street façade of flat roofed buildings. Buildings with sloped roofs shall use residential treatment.
Chamblee, GA, Building Exterior
(2) Primary frontages must be constructed at the required build to line.
(3) Where there is required open space between the proposed building and streetscape, the build to line may extend around said open space perimeter.
(4) The street-level façade (i.e., ground floor) of the building shall provide the following:
Street Level Facade Multi-Story
a. A non-glass base or knee wall below all windows beginning at grade and extending to a point no less than eight inches but not more than 24 inches above the sidewalk area at the build-to line. Knee wall may be waived when directly abutting a private patio.
b. A combination of glass display windows and doors covering a minimum of 75 percent of the area of the façade that is located along the build-to line at the ground floor of the building.
c. Glass display windows shall be clear and provide visibility into the interior the building for minimum depth of two and one-half feet.
d. Glass display windows shall be at least eight feet tall, as measured from the sidewalk.
e. Primary pedestrian entrances on the street façade shall be recessed a maximum of seven feet from the exterior façade. All other doors located along street frontage shall be of a character that matches the surrounding downtown area.
f. A glass transom measuring between 24 inches and 36 inches tall shall be installed above glass display windows and above the primary entrance door.
g. A sign band area measuring at least 36 inches in height shall be installed above the glass transom and below the building's required cornice line.
h. A cornice line measuring at least eight inches in height shall be installed above the sign band.
Street Level Facade One-Story
i. Street address numbers measuring at least six inches in height shall be installed above or to the side of the primary pedestrian entrance.
j. Finished ceiling height shall be a minimum of 18 feet on the ground floor.
k. Exterior height of single-story buildings shall be a minimum of 18 feet as measured at top of parapet. Parapet must enclose all sides of the roof.
Historia
(Ord. of 5-30-2025, § 4.3)
Leer este código donde se publica (Municode) La fuente es el código de la ciudad tal como lo publica su editorial o su propio sitio web. Consúltelo allí para ver cambios posteriores.