(a) Prohibited uses.

(1) Selfservice storage or mini-warehouse.

(2) Salvage, junk, wrecking and scrap yards.

(3) Adult bookstore.

(4) Sexually oriented businesses or establishments.

(5) Pawnshop or loan brokers, other than mortgage loan brokers.

(6) Rooming and boarding houses.

(7) Automotive repair and maintenance, except car washes.

(b) Special uses. The following use shall require special use approval in accordance with the procedures of article

XII:

(1) Outdoor commercial recreation.

(2) Car washes.

(3) Outdoor storage or display.

(4) Commercial buildings in excess of 150,000 square feet.

(5) Exceptions to building height standards as set forth in subsection (l)(6) below.

(c) Ground floor area limitation. New commercial buildings may not exceed 150,000 gross square feet in ground floor area. New commercial buildings greater than 150,000 gross square feet must obtain special use approval.

In determining whether to grant an increase in ground floorsize beyond 150,000 square feet, the Town Council shall consider the following factors, in addition to those listed in article XII:

(1) The site has safe, immediate access to the highway corridor overlay district as applicable.

(2) The building site will provide convenient inter-connections with adjacent uses and properties that serve both pedestrians and automobiles.

(3) The floor area ofthe proposed building isthe smallest feasible to serve the function of the proposed use.

(4) The architectural design of the building reduces the perceived size of the building by appropriate articulations and variations in the massing, façade, roofline, materials, colors, and textures of the building exterior.

(5) The building and site meets or exceeds all other standards set forth in this ordinance and by the Town of Bethlehem Unified Development Code.

(d) Lot standards.

(1) Minimum lot size shall be as follows:

a. For outparcels orstand-alone commercial projects: 1 acre.

b. For commercial lots within a common development with shared parking and interconnectivity: ½ acre.

(2) Minimum commercial lot frontage: 175 feet along an arterial.

(3) Non-residential lots shall be generally rectangular with a ratio of depth to frontage not greater than 4:1.

(4) Residential subdivisions shall comply with one of the following two requirements (see section 1606, Design Guidelines, Figure 1):

a. Reverse-fronting lots are required for residential subdivisions along streets classified as arterials or collectors, subject to subparagraph (b) below. Reverse-fronting residential lots shall be platted with a landscaped access easement restricting vehicular access placed adjacent to the public rightof-way. Such easement shall be a minimum of 20 feet in depth and include one of the following:

1. A continuous four-foot high solid wall constructed entirely of brick orstone masonry.

2. A four-foot high fence constructed of a combination of brick or stone masonry pillars with iron pickets.

3. A vegetated strip of canopy trees, shrubs, and groundcover that provide a full landscape buffer.

b. If a residential lot is separated from the arterial or collector street by a minimum 20-foot wide landscaped strip and a residential street, a residential lot may face an arterial or a collector street.

(e) Access managementstandards.

(1) Driveways. Driveway connections to public streets shall be consistent with the following standards:

a. Driveway connections shall not be permitted within the controlled access zone of an intersection (See section 1606, Design Guidelines, Figure 2)

b. Outparcels with less than 200 feet of road frontage are restricted to internal access only.

c. Driveways that enter a major thoroughfare at traffic signals must have at least two outbound lanes (one for each turning direction) of at least 11 feet in width, and one inbound lane with a maximum width of 11 feet.

d. No residentially developed property may have a curb cut in excess of 30 feet in width, and no nonresidential property may have a curb cut in excess of 40 feet without approval of the Town’s designee.

e. Except for single-family and two-family residences, driveway grades shall conform to the requirements of the Georgia Department of Transportation Regulations for Driveway and Encroachment Control.

f. Except where driveways are on opposite sides of a raised median, driveways on opposite sides of a street shall either directly align or have offsets of a minimum of 125 feet, as measured between the extended centerlines of such driveways.

g. Whenever possible, driveways on undivided arterials, collectorstreets, or localstreets should align with driveways (if any) on the opposite side of such street.

h. On a divided arterial street that includes a median, driveways should align with median breaks whenever possible. Driveways not meeting this standard shall be limited to right turn access and right turn egress.

i. Driveway throat length. The length of a driveway or "throat length" for a commercial or office development shall be designed in accordance with the vehicle storage required for entering and exiting vehicles to prevent vehicles from backing into the flow of traffic on the public street or causing unsafe conflicts with on-site vehicle circulation. The throat lengths specified in Table 16.1 are generally acceptable guidelines intended for the major entrance driveway of a commercial development (see section 1606, Design Guidelines, Figure 3) Table 16.1: Driveway Throat Length for Commercial Centers

Commercial Center Total Gross Floor Area Throat Length of Principal Driveway* Under 25,000 square feet 50 feet - 60 feet

25,000 - 50,000 square feet 60 feet - 85 feet 51,000 - 100,000 square feet 85 feet - 135 feet 101,000 - 150,000 square feet 135 feet - 180 feet 151,000 - 200,000 square feet 180 feet - 200 feet Over 200,000 square feet 200 feet or more Note:

* For driveways that allow right turns only the throat length may be reduced by one third.

(2) Deceleration lanes.

a. A major driveway entering a street with a regulated arterial speed greater than 35 miles per hour shall be required to provide a deceleration lane consistent with the standards set forth in Article X.

b. An acceleration or deceleration lane that would begin or end within 75 feet of another driveway or intersecting street shall be lengthened so that it connects with the adjacent street or driveway.

(f) Landscaped strip to screen parking lots and loading areas.

(1) Where a parking lot or loading area for a commercial, industrial, or institutional use is located adjacent to the public right-of-way, it shall be screened from the public right-of-way consistent with Article VIII of this Development Code.

(2) Setbacks for screening areas facing the highway corridor overlay district shall be based on future rightof-way consistent with section 1606, Design Guidelines, Figure 7.

(g) Environmental controls.

(1) Stormwater management design shall comply in all respects with the current edition of the Georgia Stormwater Management Manual.

(2) Parking lot landscaping. Parking areas shall incorporate landscaped areas as required in Article 6. Such landscaped areas shall cover at least 12 percent of the parking area.

(h) Parking requirements. Off-street parking shall be required as in Article 6 of the Town of Bethlehem Unified Development Code, except as provided in this subsection:

(1) Maximum number of parking spaces. The maximum number of parking spaces that may be constructed on impervious surfaces shall be no more than 125 percent of the minimum number of required parking spaces. Parking spaces in excess of 105 percent shall be constructed on pervious surfaces recommended in paragraph (3)(b) of this subsection.

(2) Pedestrian circulation. Parking areas shall be designed to facilitate safe and convenient use by pedestrians. Commercial and multi-family developments shall provide designated pedestrian pathways or sidewalks connecting the front entrance of the principal building to the sidewalk along the abutting street, including marked crosswalks across interior driveways. (See section 1606, Design Guidelines, Figures 4 & 5)

(3) Paving materials for parking lots.

a. All parking areas shall be paved with asphalt, concrete, or pervious materials approved by the planning and community development director.

b. Pervious paving. Recommended pervious paving materials include those described in the current edition of the Georgia Stormwater Management Manual as the Porous Concrete or Modular Porous Paver Systems under the Limited Application Stormwater Structural Controls.

c. Paving areas shall be of sufficient size and strength to support the weight ofservice vehicles.

(4) On-street parking may be permitted, where appropriate, in accordance with on-street parking standards in Article VI.

(i) Dumpsters.

(1) Location.

a. Dumpsters and trash receptacles shall be located where they are not visible from adjacent residentially-zoned properties and shall be adequately screened from view from all other adjacent properties and streets.

b. Dumpsters shall be enclosed either within a building or out of sight from public streets or located outside to the rear of the principal building.

c. Dumpsters shall be set back a minimum of five feet from all property lines. If a buffer is required on the subject property line, the dumpster shall not be located within the buffer.

(2) Pad.

a. Dumpsters shall be placed on concrete pads of sufficient size and strength to support the weight of service vehicles.

b. Restaurants and other food service establishments shall place dumpsters on concrete pads that are designed to slope into a drain that is equipped with a grease trap.

(j) Lighting.

(1) Streetlights.

a. Streetlights shall be provided on all public streets; provided, however, that within the right-of-way of State Routes, SR 11 or 316 as applicable, as streetlights are not required.

b. The spacing ofstreet lights shall be staggered, 150 feet on-center, along both sides of the roadway.

c. Allstreet lighting shall be subject to review and approval of the Town of Bethlehem designee.

d. All roadway lighting, streetlights, and parking lights shall be the full cutoff type. Pedestrian lights shall be the semi-cutoff, cutoff, or full-cutoff type.

e. Streetlights shall be consistent with Table 16.2 and section 1607, Design Guidelines, Figure 7.

(2) Parking lot, sidewalk, and building illumination.

a. Lighting shall be designed to prevent light spillover on to adjacent properties. All lighting shall be fully shielded, have recessed luminaries, or be cut-off luminary fixtures mounted in such a manner that the cone of light is directed downward and does not cross any property line of the site.

b. Only incandescent, florescent, light-emitting diode (LED), metal halide, low-pressure sodium, or color corrected, high-pressure sodium may be used. The same type of lighting must be used for the same or similar types of lighting on any one site.

c. Pedestrian lights shall be consistent with Table 16.2. and section 1606, Design Guidelines, Figure 7

d. Parking light fixtures shall be the box head type, shall have a maximum height of 35 feet, and shall employ a fluted pole. All parking light fixtures and poles shall be black.

Table 16.2: Lighting Specifications Streetlight Pedestrian Light Parking Light Maximum Height 40' 15' 35' Color Black Black Black Pole Type Unspecified Fluted Fluted Fixture Type Cobra Head See Figure 7 of the Design Guidelines Box Head Shielding Full-cutoff Semi-cutoff, cutoff, or full-cutoff Full-cutoff Spacing 150' on center unspecified unspecified

* Collector streets only. Streetlights on other streets may employ other fixture types per approval of the Town’s designee.

(3) Security lighting restrictions.

a. Full cutoff luminaries shall be used for all security lighting.

b. The number of luminaires remaining on for security lighting shall not exceed one fourth the total number of each type of luminaire number by four, any remainder is counted as a whole number.

(4) Sign illumination.

a. Neon signs and internally illuminated window signs are prohibited.

b. Signs may be illuminated with external lighting fixtures provided that fixtures are directed downward and away from streets and adjacent property and public streets. All lighting shall be fully shielded, have recessed luminaries, or be full cut-off luminary fixtures.

c. Signs may be illuminated as set forth in section 89-787.

(5) Drive-under canopies and pump islands at fueling stations. The luminaire shall be recessed into the canopy ceiling so that the bottom of the luminaire does not extend below the ceiling.

(k) Architecturalstandards. The following design guidelines and standards apply to all newly constructed buildings used for multifamily residential, office or commercial purposes. These standards do not apply to single-family residential, duplex, industrial, storage or warehouse uses.

(1) General architectural requirements.

a. The use of a common palette of building materials should be maintained for building facades to create a consistent and traditional architectural identity. Traditional architecture shall include, for example, the use of brick, pitched roofs, low-profile signage, and subdued colors. For large commercial/retail buildings and multifamily buildings, variations in façade, roofline and depth should be provided to lend the appearance of multi-tenant occupancy. All design and construction shall be subject to architectural review by the town or its designated architect to ensure adherence with this subsection (k) and the structures of traditional architecture.

b. All ground or roof-mounted mechanical, HVAC, and like systems shall be screened from public street view (within 300 feet) on all sides by an opaque wall or fence made of brick, stucco, split face block, or landscaping.

c. For all commercial buildings, roof-mounted mechanical, HVAC, and like systems shall be screened from public street view (within 300 feet) on all sides by a raised parapet or pitched roof along the edge of the roofline.

d. Contrasting accent colors on any single facade shall be limited to no more than ten percent of the total wall area for any single facade.

e. Permanent mounted exterior neon lights shall not be allowed.

f. Buildings that are located on outparcels and all accessory buildings shall be constructed of materials complementing the principal building with which they are associated.

g. Back-lit awnings, roof-mounted lights, and/or roof mounted flag poles are not permitted. Satellite dishes shall be located and painted to blend with the background as much as practical.

(2) Building materials. Table 16.3 and this sub-section outlines allowed building materials that are may be used and combined to create a consistent, attractive, interesting and long-lasting building design:

a. Allowed building materials.

1. Brick, except that brick veneers that are intended to simulate brick exteriors are not acceptable;

2. Stone. Natural stone such as, but not limited to, granite, limestone, acid marble are allowed building materials. Terra cotta and/or cast stone, which simulate natural stone, are also acceptable. Painted stone is not allowed;

3. Split-face block/concrete masonry unit (CMU) is restricted to ten percent of the surface area of the facade;

4. Tilt/architectural pre-cast concrete is not allowed;

5. High grade stucco is restricted to 50 percent of the surface area of a facade;

6. Natural wood and/or cement-based artificial wood siding are allowed only for residential buildings;

7. Glass;

8. Exposed concrete block, metal, and tile are not allowed as building materials on a façade.

Table 16.3 Allowable Building Materials Brick Stone Glass Tilt/PreCast Stucco Concrete Blocks CMU/SplitFace Block Siding Metal Tile Yes Yes Yes No Max.

50% per facade No Max. 10% per facade No* No No Note: * Allowed for residential buildings. Buildings must have a minimum 4:12 roof pitch.

b. Ratios and amounts of allowed building materials.

1. Accent/trim exterior building material. Small amounts of building materials such as wood, tile, etc., may be used to enhance the facade of the building or for decorative elements, but should not exceed 10% of total wall area per facade.

2. Facade calculations. With the exception of accent/trim materials, there shall be no more than two primary building materials used. When stucco is used as a building material for a façade, it is restricted to 50 percent of the total. The allowed facade materials shall not apply to entry doors and/or roll-up doors.

c. The amount of permitted material shall be calculated using the gross square footage of wall area per façade.

For example, a building has a front facade with a gross facade area of 1,200 square feet with 400 square feet consisting of windows and doors. Begin with 1,200 square feet for required building material calculations. A wall area of 1,200 square feet shall have no more than 600 square feet of stucco on the front facade [e.g. (1,200 X 50% = 600)]. The balance shall be brick or other allowed material. Trim or accent material may account for up to ten percent or 120 square feet.

(3) Roof requirements. Materials for pitched roofs shall be limited to architectural dimensional grade asphalt shingles, natural slate, natural terra cotta, natural wood shake, copper or factory finished sheet metal.

a. Pitched roofs. All buildings less than 5,000 square feet of gross floor area must have a pitched roof with a minimum pitch of 4:12. All one-story buildings less than 10,000 gross square feet must have a pitched roof (between 3:12 and 12:12); provided, however, that if a pitched roof is not possible, a combination of flat roof and pitched roof is required. Provide a pitched roof on front and side of the building to screen view of any flat roof. Create arcades, drive-under canopies, porches, and other features with pitched roof.

b. Mansard roofs. Mansard roofs shall have a maximum pitch of 12:12 with a minimum 12-foot vertical surface length.

c. Flat roofs. Building materials for flat roofs shall meet local codes.

d. Exposed metal flashing shall be copper or factory finished sheet metal. If factory finished metal flashing is used, such as standing seam, the color must be subdued to blend with other materials or of a color to simulate weathered copper or bronze. All buildings with flat roofs should include parapet articulation on the front facade(s) ofsuch building. There shall be roof articulations/offsets at a minimum of one per each 125 linear feet of length by a change in the top line of the parapet.

Additional articulation may occur at any lesser distance. If the front facade is less than 125 linear feet of length, then a minimum of one roof articulation must occur.

e. Other. Drive under canopies for gasoline pumps may have flat roof with vertical or factory formed facing of finished sheet metal.

(4) Arcade/structural canopy for retail use. For any multi-tenant commercial development, a covered arcade/structural canopy shall be provided along the front facade of the building. Arcades are covered walkways connected to the principal building. They should be a minimum of five feet in width and designed to provide covered areas for relief from the weather. Different arcade/structural canopy designs may be used for each individual tenant/business within a multi-tenant commercial development provided that they blend aesthetically with the front facade of the building and has the approval of the building owner and the Town’s designee.

(5) Street orientation. Principal building entrances shall be oriented to public streets.

(6) Building height. Any building of which 50 percent or more is located within 250 feet of the centerline of an arterial street shall be no more than three stories in height.

A relief from height restrictions shall only be allowed if special use approval is granted by the Town Council, in accordance with procedures in Article XII of the Town of Bethlehem Unified Development Code. In deciding whether to grant a height increase, the Town Council shall consider the following factors, in addition to those listed in Article XII.

a. Proximity and relationship of the proposed building to other buildings that are more than three stories or 35 feet in height.

b. Impact of the proposed building on single-family residences on nearby tracts.

c. Topography and vegetation that screen the view of the proposed building.

d. On-site screening and/or landscaped buffers.

e. Provision of public open space in exchange for increased building height.

f. The effect of additional building height on traffic congestion.

g. Access of the site to major traffic arteries.

h. Economic development opportunities for the Town of Bethlehem.

i. The necessity of greater building height to the function of the proposed use.

j. The quality of the architectural design and its compatibility with its surroundings.

(7) Building massing and modulation. (See section 1606, Design Guidelines, Figure 6.) The massing of building facades longer than 150 feet that are approximately parallel to the right-of-way and oriented to a public street shall be modulated to increase visual interest, as follows.

a. Building facades that are less than 500 feet long shall be modulated at intervals no greater than 100 feet in length.

b. Building facades that are more than 500 feet long shall be modulated with intervals no greater than 20 percent of the length of the façade.

(8) No non-residential building shall have less than 2,000 square feet of heated floorspace.

(9) Building design shall include minimum one-foot deep cornices along the entire front façade of buildings and extending for a distance of at least ten feet along the sides of buildings.

(10) Building designs shall include a minimum two-foot high contrasting base, along the entire front façade of buildings and extending for a distance of at least ten feet along the sides of buildings.

(11) Satellite dish antennae. No satellite dishes shall be permitted within view from public streets.

(12) Off-street loading areas. Off-street loading areas shall be located in the rear of buildings and screened from view from adjacent property or streets.

(l) Signage. Except as provided in this subsection, signage shall comply with the regulations in Article VII of the Town of Bethlehem Unified Development Code.

(1) Freestanding and project entrance signs shall be limited to ground signs. round signs shall be limited to base and sign structure shall be constructed of materials such as brick, stone, stucco, wood or metal consistent with the architecture and exterior treatment of the building.

(2) The maximum sign area of any ground sign, inclusive of any border and trim, but excluding the base, apron, supports and other structural members shall be:

a. Ground signs on lots zoned commercial or industrial, including shared signs, on lots with more than one tenant shall be no greater than 50 square feet in sign area.

b. Ground signs on lots zoned commercial or industrial with one tenant shall be no greater than 32 square feet in sign area.

c. Ground signs on lots zoned O-I shall be no greater than 32 square feet of sign area.

d. Ground signs for single business premises shall be no greater than 32 square feet in sign area.

Leer este código donde se publica (city website) La fuente es el código de la ciudad tal como lo publica su editorial o su propio sitio web. Consúltelo allí para ver cambios posteriores.