Blue Ridge · Ordenanza de zonificación
Part III - LAND USE CODE / Chapter 105 - BUILDING REGULATIONS / Article III - ADMINISTRATION AND ENFORCEMENT
Sec. 105-106. Compliance alternatives.
Sobre este texto
- As published by Municode, retrieved 2026-11-11
- The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.
Las notas de arriba, el texto de la sección y su línea de historia se muestran en inglés, tal como los publica la fuente y como los da el corpus.
Subsections (1) through (5) of this section contain generally acceptable compliance alternatives illustrating principles which shall be applied to the rehabilitation of existing buildings by enforcement authorities in the city. It is recognized, for purposes of this article, that all building systems interact with each other; therefore, any consideration of compliance alternatives should take into account all existing and proposed conditions to determine their acceptability. The compliance alternatives are not allinclusive and do not preclude consideration and approval of other alternatives by any enforcement authority.
(1) Compliance alternatives for an inadequate number of exits include, but are not limited to, the following:
a. Provide connecting fire exit balconies acceptable to the enforcement authority between buildings;
b. Provide alternate exit or egress facilities leading to safety outside the building or to a place of safe refuge in the building or an adjoining building as acceptable to the enforcement authority;
c. Provide an exterior fire escape as acceptable to the enforcement authority where the providing of enclosed interior or enclosed exterior stairs is not practical; or
d. Install early fire warning and fire suppression systems (monitored alarm system, sprinklers or as defined by life safety codes).
(2) Compliance alternatives for excessive travel distances to an approved exit include, but are not limited to, the following:
a. Install an approved smoke detection system throughout the building;
b. Install an approved complete automatic fire suppression system;
c. Subdivide the exit travel route with smoke-stop doors acceptable to the enforcement authority;
d. Increase the fire resistance rating of corridor walls and doors as defined by the enforcement authority; or
e. Provide additional approved means of escape.
(3) Compliance alternatives for unenclosed or improperly enclosed exit stairways or vertical shafts include, but are not limited to, the following:
a. Improve enclosure of exit stairway;
b. Add a partial fire suppression system;
c. Add a sprinkler draft curtain; or
d. Add a monitored smoke detection system.
(4) Compliance alternatives for inadequate or a total lack of fire partitions or fire separation walls shall be as set forth in subsection (3) of this section.
(5) Compliance alternatives for a lack of required protection of openings in exterior walls where a fire exposure is a risk include, but are not limited to, the following:
a. Improve fire resistance of existing openings and protect them with fire-rated windows or doors as appropriate;
b. Seal the openings with fire-rated construction as approved by the enforcement authority;
or
c. Install an approved fire suppression system.
Historia
(Ord. of 11-1-2005, exh. A, § 1.43)