Sec. 140-376. Plans required.

Sobre este texto

  • As published by Municode, retrieved 2026-11-11
  • The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.

Las notas de arriba, el texto de la sección y su línea de historia se muestran en inglés, tal como los publica la fuente y como los da el corpus.

(a) A landscaping plan prepared by a professional landscape architect shall be approved by the City Administrator or his/her designee prior to the issuance of a building permit, to demonstrate compliance with the provisions of this article, conditions of zoning, variance or conditional use approval, or other regulations of the City of Blue Ridge.

(b) The landscape plan shall be to-scale, shall be based on an accurate boundary survey of the site or reasonable property description, shall be no greater than 20 by 24 inches, and shall include the following:

(1) Delineation of all minimum yard areas, buffers, and landscape areas as required by the City of Blue Ridge Land Use Code, conditions of zoning, or variance or conditional use approval.

(2) Location and general type of existing vegetation and trees;

(3) Existing vegetation and trees to be saved;

(4) All trees ten inches in DBH or greater to be removed (see also Sec. 140-385);

(5) If replacement trees are proposed to be planted, the replacement trees shall be shown and their spacing and diameter identified, to the extent needed to achieve the minimum requirements;

(6) Methods and details for protecting existing vegetation and trees during construction;

(7) Locations and labels for all proposed plants/trees and a plant/tree list or schedule showing the proposed and minimum required quantities;

(8) Location and description of other landscape improvements, such as buffers, earth berms, walls, fences, screens, sculptures, fountains, street furniture, lights, and courts or paved areas;

(9) Locations of proposed on-site underground utility lines;

(10) Locations of other on-site and off-site utility lines. Indicate areas where trees can't be planted because of interference with existing or proposed utilities on public rights-of-way or easements and existing utilities on adjoining properties; and

(11) Limits of land disturbance, clearing, grading, and trenching. Sec. 140-377. Buffers required.

(a) Applicability.

(1) Buffers shall be required as specified in this article or for particular uses when specified in any other article of this Zoning Ordinance.

(2) The Blue Ridge City Council may establish minimum buffer requirements in situations other than those given in this article as a condition of zoning or as part of conditional use or variance approval.

(b) Location.

(1) Buffers shall be located on the outer perimeter of a lot or parcel along all lines adjoining dissimilar districts per Table 140-377, unless separated by an existing right-of-way. The buffer is normally calculated as parallel to the property line;

however, design variations are allowed upon approval by the City Administrator or his/her designee.

(2) Buffers shall not be located on any portions of existing, dedicated, or reserved public or private street rights-of-way. Buffers shall not be used for parking. A buffer area may be used for vehicular access and utility easements (only if such uses are provided approximately perpendicular to the greater distance of the buffer area) and for drainage improvements required by the city.

(c) Buffer requirements by zoning district.

(1) When two adjoining properties are in different zoning districts, the property within the more intensive district is required to provide the buffer type as indicated in Table 140-377.

(2) When two adjoining vacant parcels are in different land use districts as indicated in Table 140-377, no buffer is required when the parcel in the less intensive district acquires a building permit.

Table 140-377 Buffer Types by Zoning District Zone District least intensive ... Zone District ... most intensive

R-A R-1 R-2 R-3 C-1 C-2 CBD M-1

R-A None None I I II II I III R-1 None None None I I II I III R-2 I None None None I II I III R-3 I I None None None II I III C-1 II I I None None None None III C-2 II II II II None None None II CBD I I I I None None None II

M-1 III III III III III II II None

(3) Type I buffer requirement. The required buffer shall have not less than a 12-foot width and shall consist of plantings that meet the screening standards of section 140-378.

(4) Type II buffer requirement. The required buffer shall have not less than a 15-foot width and shall consist of plantings that meet the screening standards of section 140-378.

(5) Type III buffer requirement. The required buffer shall have not less than a 30-foot width and shall consist of plantings, plus a fence, wall (not otherwise a part of a structure), or berm, or any combination thereof that meet the screening standards of section 140-378.

Historia

La línea de historia que la fuente imprime al final de la sección.

(Ord. No. BR2023-20, § 2(Exh. B), 8-15-2023)