Bogart · Ordenanza de zonificación
Article 11 - Erosion Control and Stormwater Management / Division IV - FLOOD DAMAGE PREVENTION / 1133 - Provisions for flood hazard reduction.
Sec. 1133.04. Standards for areas of shallow flooding (AO zones).
Sobre este texto
- As posted on the city's website, retrieved 2026-11-14
Las notas de arriba, el texto de la sección y su línea de historia se muestran en inglés, tal como los publica la fuente y como los da el corpus.
Located within areas of special flood hazard are areas designated as shallow flooding areas.
These areas have special flood hazards associated with base flood depths of one to three feet where a clearly defined channel does not exist and where the path of flooding is unpredictable and indeterminate. The following provisions apply in these areas:
a. New construction and substantial improvements.
All new construction and substantial improvements of residential and nonresidential structures shall have the lowest floor, including basement, elevated to the depth number specified on the flood insurance rate map, in feet, above the highest adjacent grade. If no flood depth number is specified, the lowest floor, including basement, shall be elevated at least 3 feet above the highest adjacent grade. Openings sufficient to facilitate the unimpeded movements of floodwaters shall be provided in accordance with the standards for elevated buildings, above.
A registered professional engineer shall certify the lowest floor elevation level and the record shall become a permanent part of the permit file.
b. Nonresidential buildings.
All new construction and substantial improvements of nonresidential structures may be flood-proofed. The structures, together with attendant utility and sanitary facilities, must be designed to be watertight to the specified FIRM flood level plus 1 foot, above highest adjacent grade, with walls substantially impermeable to the passage of water, and with structural components having the capability of resisting hydrostatic and hydrodynamic loads and the effects of buoyancy. A registered professional engineer or architect shall certify in writing to the Code Enforcement Director that the design and methods of construction are in accordance with accepted standards of practice for meeting the provisions above.
c. Drainage paths.
Drainage paths shall be provided to guide floodwater around and away from any proposed structure.
Leer este código donde se publica (city website) La fuente es el código de la ciudad tal como lo publica su editorial o su propio sitio web. Consúltelo allí para ver cambios posteriores.