Bogart · Ordenanza de zonificación
Article 4 - Lot and Building Standards
4-14. Summary—Dimensional Requirements
Sobre este texto
- As posted on the city's website, retrieved 2026-11-14
Las notas de arriba, el texto de la sección y su línea de historia se muestran en inglés, tal como los publica la fuente y como los da el corpus.
1 Minimum lot size varies depending on the number of lots in a minor subdivision, refer to UDC Sec. 503.
2 Properties (a) which were rezoned for a major subdivision prior to July 2, 2019, shall be permitted to be developed pursuant to the approved concept plan, specifically including, without limitation, the use of the minimum lot sizes allowed under the provisions of this ordinance as of July 1, 2019, and (b) those which were subject to an enforceable legal obligation to be purchased as of July 2, 2019, and which receive preliminary plat approval on or before December 29, 2019, shall be permitted to be developed using the minimum lot sizes allowed under the provisions of this ordinance as of July 1, 2019.
3 The minimum lot size in the AR and AR-3 zoning districts may be reduced only in accordance with the provisions for “conservations subdivisions” and only in accordance with a conservation subdivision plan which has been approved by the Mayor and Council.
4 Figures shown are for lots in a manufactured home subdivision. For a manufactured home park (sewer required), maximum density is 2.5 units per acre and the minimum area for each manufactured home space or stand is 17,000 sf per home; minimum site size is 10 acres.
5 Lot Area per dwelling unit.
6 Or minimum required by County Health Department, whichever is greater.
7 Figures shown are for a two-family dwelling on one lot. Minimum lot widths for a two-family dwelling on two lots shall be ½ the figures shown.
8 If the building height exceeds 40 feet and/or is above the capability of normal firefighting equipment, local fire officials shall certify that such building, as proposed to be located, constructed, and equipped, and particularly the upper stories, has adequate sprinkler equipment or other built-in equipment to provide fire protection.
9 Maximum building height for principal buildings may be increased up 85 feet by Special Use Approval.
10 See Sec. 410 for accessory structure setbacks.
11 Zero side yard setbacks can be permitted on individual lots with no more than two connected units.
12 No side yard setbacks required between attached units; 10 foot side yard or 20 feet of separation between buildings.
13 See separation requirements for certain uses in Article 3.
14 For commercial developments with shared stormwater detention facilities, the average lot coverage for all parcels in the development may be used to determine compliance with maximum percent lot coverage.
Table 4.1: Dimensional Requirements by Zoning District
MINIMUM FLOOR AREA
PER DU: PRINCIPAL
BUILDINGS 15 (SF)
CBD AR-3 AR R-1 R-2 R-3 M-H OIP B-1 B-2 OBP I
- 1600 (1 story) 1600 (1 story) 1600 (1 story) 1600 (single family, 1 story) 1600 (single family, 1 story) 1000 (manufactured home subdivision or manufactured home park)
- - - - - 1850 (2 story) 1850 (2 stories) 1850 (2 stories) 1850 (single family, 2 stories) 1850 (single family, 2 stories) 1500 (two family, per DU) 1500 (two family, per DU) Multi Family:
800 (efficiency or onebedroom) 900 (2 bedroom) (3 bedroom) 15 See definition of “floor area, heated.”
BLANK PAGE
Leer este código donde se publica (city website) La fuente es el código de la ciudad tal como lo publica su editorial o su propio sitio web. Consúltelo allí para ver cambios posteriores.