Ir al contenido
Georgia Commons
Menú

Bogart · Ordenanza de zonificación

Article 9 - Environmental Protection / Division III - AQUIFER RECHARGE AREA PROTECTION

Sec. 913. Aquifer protection standards.

Sobre este texto

  • As posted on the city's website, retrieved 2026-11-14

Las notas de arriba, el texto de la sección y su línea de historia se muestran en inglés, tal como los publica la fuente y como los da el corpus.

a. Waste disposal.

(1) For all pollution susceptibility areas, new solid waste disposal facilities must have synthetic liners and leachate collection systems.

(2) No land disposal of hazardous waste shall be permitted within any Significant Aquifer Recharge Area.

(3) Any new facility that involves the treatment, storage or disposal of hazardous waste, if permitted by DNR and the zoning district, shall perform such operations on an impermeable surface having a spill and leak collection system.

(4) Any new facility that handles hazardous materials of the types listed in Section 312 of the Resource Conservation and Recovery Act of 1976 (excluding underground storage tanks) and in amounts of 10,000 pounds or more on any one day, shall perform their operations on impermeable surfaces having spill and leak collection systems as prescribed by DNR.

b. Agricultural waste impoundment.

New agricultural waste impoundment sites shall be lined if they exceed 50 acre-feet. As a minimum, the liner shall be constructed of compacted clay having a thickness of onefoot and a vertical hydraulic conductivity of less than 5 x 10-7cm/sec or other criteria established by the U.S. Soil Conservation Service.

c. Chemical or petroleum storage tanks.

For all Significant Aquifer Recharge Areas, new above-ground chemical or petroleum storage tanks larger than 650 gallons must have secondary containment for 110 percent of tank volume or 110 percent of the largest tanks in a cluster of tanks. Such tanks used for agricultural purposes are exempt, provided they comply with all federal requirements.

d. New construction on septic tanks.

Within all significant aquifer recharge areas, construction shall not proceed on a building, mobile home or manufactured home to be served by a septic tank or on-site sewage management system unless the the City of Bogart Health Department first approves the proposed septic system installation as meeting the requirements of Section M of the Georgia Department of Human Resources Manual for On-Site Sewage Management Systems relating to protection of groundwater recharge areas. Such State requirements are also found under the Rules of the Department of Natural Resources, Environmental Protection Division, Chapter 391-3-16-.02.

Leer este código donde se publica (city website) La fuente es el código de la ciudad tal como lo publica su editorial o su propio sitio web. Consúltelo allí para ver cambios posteriores.

Versión local-code:bogart/zoning/913@2026-11-14-e5940c2d28

El asistente puede decir lo que dice esta sección en esta edición, citándola y enlazándola. No aplicará la ley a su situación, y nada de esto es asesoría legal.

Bogart Zoning Ordinance, Sec. 913. Aquifer protection standards | Georgia Commons