This District is established as a high-density residential district for two-family residences, multi-family residences.
Uses Permitted:
1. Any uses permitted in R-1 and R-2 Districts, subject to restrictions of the R-1 and R-2 respectively.
2. Two-family residences.
3. Multi-family residences.
4. The home shall also include the following improvements:
(a) All homes shall be on a permanent foundation, slab on grade or raised perimeter foundation, as is required by the State Minimum Standard Codes. Raised foundation walls shall be solid except for the openings that are needed for ventilation and access as required by the applicable building code.
(b) All homes shall have a landing at all egress doors that is a minimum of 6'X6'. The landing at the exterior of an egress doorway shall not be more than 8 ½" inches below the top of the threshold.
Accessory Uses.
Customary accessory buildings or structures, provided such shall be permitted only in rear yard, and shall not be less than ten feet (10') from any property line; and further provided that in the case of corner lots, such buildings or structures shall be set back at least twenty (20') feet from any side street right-of-way line.
Area and Dimensional Requirements.
Within any R-3 Residential District as shown on the Zoning Map, the following dimensional requirements shall be complied with:
1. Minimum required lot for each dwelling unit is seven thousand (7,000) square feet.
2. Minimum required lot width is one hundred twenty feet (120') for the first dwelling unit, plus an additional ten feet (10') of lot width for each unit in excess of one (1).
3. Minimum required front yard is fifty feet (50').
4. Minimum required side yard is fifteen feet (15'), except where adjourning or abutting an R-1 or R-2 District, the property side yard shall be fifty feet (50'). Corner lots must have an additional ten feet (10') along the sideline.
5. Minimum required rear yard is fifty feet (50').
6. Maximum permissible lot coverage: The total ground area covered by the principal buildings shall not exceed fifty percent (50%) of the total lot area.
7. Where water and sewer facilities are not available, lot area and dimensions must be as specified by the Carroll County Health Department as follows:
Lot Width: One hundred feet (100') at building line per dwelling.
Lot Area: One acre per dwelling.