A. Façade materials (excluding windows, doors, trim, soffits, porches, balconies, gutters, or architectural details) are limited to the following:

1. Buildings containing exclusively residential uses or, in districts that use building types, the following building types: detached

house, carriage house, cottage court, duplex, townhouse, walk-up flat, conventional multifamily, and commercial house.

a. True masonry brick, but not brick veneers or EIFS or precast concrete that simulates the appearance of brick.

b. Stone, including unpainted natural stone, unpainted cast stone having the appearance of natural stone, and unpainted terra cotta

c. Stucco, including true cement stucco but not EIFS.

d. Wood, including natural wood, engineered wood, or cementitious siding.

e. Shingles, including wood or cementitious shakes and shingles.

f. For any principal residential building allowed pursuant to Sections 4.2 (R-2)

and 4.3 (R-3), the front, rear, and side facades shall be limited to the

materials listed above in Section 6.4, A., 1., a. and b.

2. Buildings containing any commercial use as a primary use or, in districts that use building types: the following building types:

storefront, mixed-use building, general building, and civic building.

a. True masonry brick, including brick veneers, but not EIFS.

b. Stone, including unpainted natural stone, unpainted cast stone having the appearance of natural stone, and unpainted terra cotta.

c. Stucco, including true cement stucco;

multi-layered.

d. EIFS, provided that it does not exceed 50% of the area of any building façade

not counting any windows, doors, trim, or soffits.

e. Glass.

f. Metal panels, but not corrugated metal.

3. Buildings containing any industrial use as a primary use in any district.

a. True masonry brick, including brick veneers, and precast concrete that simulates the appearance of brick.

b. Concrete block only on façades that do not face any adjacent street and where

it is painted or tinted to blend with the rest of the façade.

c. Split-face concrete block, provided that it does not exceed 25% of the area of

any building façade that faces any adjacent street, not counting any windows, doors, trim, or soffits.

d. Stone, including unpainted natural stone, unpainted cast stone having the appearance of natural stone, and unpainted terra cotta.

e. Stucco, including true cement stucco.

f. EIFS, provided that it does not exceed 50% of the area of any building façade

not counting any windows, doors, trim, or soffits.

g. Tilt/architectural pre-cast concrete.

h. Glass.

i. Metal panels.

B. No more than three different exterior finish materials, textures, colors, or combinations of these may be used on a single building,

excluding materials for windows, doors, trim, porches, balconies, gutters, foundations, or architectural details.

C. When a material is restricted to a maximum percentage of the façade, it may not be

combined with another material that also has a maximum percentage restriction.

D. Foundations, when visible, must be constructed as a distinct building element that is finished in a different material or color.

Above-ground foundations must be coated or faced in cement, hard coat stucco, brick, natural stone, or cast stone to contrast with façade materials.

E. Identical façade designs must not be used for more than two dwellings or buildings on the same block face, or for buildings that face each other across a street. For townhouses, identical façade designs must not be used for more than six dwellings on the same block face, or for buildings that face each other across a street. Differentiation between adjacent façades may be accomplished by a change in materials, building height, color, or roof form.

F. Façades over 200 feet in length and facing any street must incorporate façade

projections or recesses a minimum of 12 inches in depth and occurring at intervals no greater than 20 percent of the length of the façade or 100 feet, whichever is more.

G. Where provided, cornices with a depth of at least 12 inches but no more than 24 inches must be provided along the entire length of any façade facing any street and extending for a distance of at least 10 feet along the side façades beginning at the front façade. No cornice may be more than 36 inches in height.

H. Any façade facing any street must incorporate changes in building material, color, or details such as windows, trellises, false windows or recessed panels reminiscent of windows,

doors, or colonnade openings every 75 linear feet.

I. All canopy faces and support columns for gas station fuel canopies or drive-through

canopies must be completely wrapped in brick, natural stone, or unpainted cast stone.

J. Additional standards for drive-through design are provided in Sec. 5.4H.

Reuniones que se refieren a esta sección

Encontradas: 1. Son reuniones de este gobierno cuyas actas o transcripciones automáticas nombran esta sección, o una ordenanza de su línea de historia, de la más reciente a la más antigua. Halladas por regla a partir de las propias palabras de esos registros. Una referencia es un enlace a otro registro, no una afirmación de que la sección se aplica o se cambió.

Leer este código donde se publica (city website (Revize)) La fuente es el código de la ciudad tal como lo publica su editorial o su propio sitio web. Consúltelo allí para ver cambios posteriores.

Versión local-code:braselton/zoning/6.4@2026-11-11-5908a8846e

El asistente puede decir lo que dice esta sección en esta edición, citándola y enlazándola. No aplicará la ley a su situación, y nada de esto es asesoría legal.

Braselton Zoning Ordinance, 6.4. Façade Materials and Design | Georgia Commons