Bremen · Ordenanza de zonificación
Part III - LAND DEVELOPMENT CODE / Chapter 108 - FLOOD DAMAGE PREVENTION / Article IV - PROVISIONS FOR FLOOD HAZARD REDUCTION
Sec. 108-79. Building standards for streams without established base flood elevations and/or floodway (A Zones).
Sobre este texto
- As published by Municode, current through 2025-10-13
- The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.
Las notas de arriba, el texto de la sección y su línea de historia se muestran en inglés, tal como los publica la fuente y como los da el corpus.
Located within the areas of special flood hazard established in section 108-28, where streams exist but no base flood data have been provided (A Zones), or where base flood data have been provided but a floodway has not been delineated, the following provisions apply:
(1) When base flood elevation data or floodway data have not been provided in accordance with section 108-28, then the city manager or his designee shall obtain, review, and reasonably utilize any scientific or historic base flood elevation and floodway data available from a federal, state, or other source, in order to administer the provisions of this article. Only if data are not available from these sources, then the following subsections (2) and (3) of this section shall apply:
(2) No encroachments, including structures or fill material, shall be located within an area equal to the width of the stream or 20 feet, whichever is greater, measured from the top of the stream bank, unless certification by a registered professional engineer is provided demonstrating that such encroachment shall not result in more than a one-foot increase in flood levels during the occurrence of the base flood discharge.
(3) In special flood hazard areas without base flood elevation data, new construction and substantial improvements of existing structures shall have the lowest floor of the lowest enclosed area (including basement) elevated no less than three feet above the highest adjacent grade at the building site. (Note: Require the lowest floor to be elevated one foot above the estimated base flood elevation in A Zone areas where a Limited Detail Study has been completed). Openings sufficient to facilitate the unimpeded movements of floodwaters shall be provided in accordance with standards of section 108-77(4), "elevated buildings."
(4) All heating and air conditioning equipment and components (including ductwork), all electrical, ventilation, plumbing, and other service facilities shall be elevated no less than three feet above the highest adjacent grade at the building site.
(5) The city manager or his designee shall certify the lowest floor elevation level and the record shall become a permanent part of the permit file.
Historia
(Ord. No. 2008-05-19, art. 4, § C, 5-19-2008)
Leer este código donde se publica (Municode) La fuente es el código de la ciudad tal como lo publica su editorial o su propio sitio web. Consúltelo allí para ver cambios posteriores.