Ir al contenido
Georgia Commons
Menú

Bremen · Ordenanza de zonificación

Part III - LAND DEVELOPMENT CODE / Chapter 120 - SUBDIVISION AND PLATTING REGULATIONS / Article III - GENERAL REQUIREMENTS FOR SUBDIVISIONS

Sec. 120-67. General requirements.

Sobre este texto

  • As published by Municode, current through 2025-10-13
  • The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.

Las notas de arriba, el texto de la sección y su línea de historia se muestran en inglés, tal como los publica la fuente y como los da el corpus.

(a) Suitability of land. Land subject to flooding, improper drainage or erosion, or land that is for topographical or other reasons unsuitable for residential use or for any other use that will continue or increase the danger to health and safety and of property destruction, shall not be developed unless the hazards can be and are corrected. No area situated in wetlands shall be considered for development without adequate mitigation measures as mandated by the Army Corps of Engineers.

(b) Preservation of trees and other natural growth. The subdivider shall preserve all trees and other natural growth to the maximum extent feasible and demonstrate such preservation through plans and text.

(c) Access. Every subdivision or site shall be provided access to a public street.

(d) In-fill housing in existing neighborhoods. New in-fill housing units in existing neighborhoods shall either conform substantially to the square footage of adjacent housing and/or shall not be less than 1,400 square feet. The square footage shall be determined by the units on either side of the adjoining lots and the lots to the front and rear, but in no manner shall the in-fill units square footage be less than any of the adjacent properties. The design and/or architectural style of the new structure shall closely resemble that of the existing structures.

(e) Group projects. Group projects shall prepare a site plan and construction drawings in accordance with those requirements outlined in this chapter.

(f) Utility and drainage easements.

(1) An easement shall be provided for all utilities and structures located out of the right-of-way. Such easements shall extend a minimum of ten feet out from the outermost part of the structure, but shall not be less than 20 feet in total width. All storm drains shall extend to within 20 feet of the stormwater management facilities leaving room for energy dissipating measures. Should energy dissipation require more than 20 linear feet, a variance shall be required prior to construction of the storm drainage system.

(2) When located within the same permanent utility easement water and sewer lines shall be separated ten feet horizontally and 24 inches vertically.

(3) All utilities for new subdivisions shall be buried. The waterlines shall be located five feet inside the right-of-way on the side of the developer's choice. The sewer line shall be ten feet off the curb opposite the waterline. The gas main shall be a maximum of three feet off the curb on either side. Power, telephone, cable, and any other utility location shall be coordinated with the appropriate service provider.

(g) Minimum house and lot size. The minimum square footage for a house in a new subdivision shall be 1,400 square feet, unless the final plat has been approved and recorded at the time of the adoption of this section. The minimum lot size shall be 21,780 square feet or

0.50 acre in new subdivisions. The planning and zoning commission may waive the minimum square footage requirements for a home only if The lot is not of sufficient size to accommodate a house to the minimum square footage due to a permanent easement bisecting the lot.

(h) Portable toilets required at all construction sites. Portable toilets shall be made available at all subdivision, PUD and remodeling construction sites unless an administrative waiver is granted by the codes enforcement officer. Any waiver granted will be based on the size and scope of the project and if other facilities are provided by the owner of the project. This waiver shall not be granted for any PUDs, subdivisions, or new construction sites unless significant accommodations have been made and can be documented to the codes enforcement officer.

(i) Temporary mail boxes at construction sites. Temporary mail boxes shall be placed at all subdivision and new construction sites. The temporary mail boxes shall be placed at the entrance of a subdivision and/or construction sites for the purpose of receiving billings from utility companies, i.e., Georgia Power. The mail box shall be located on a post two inches by four inches, until a permanent mail box is available for the subdivision or construction site. This installation of said mail box shall be the responsibility of the developer.

(j) Posting of address numbers for all developed lots. Addresses shall be posted in a visible area on the property to ensure proper mail delivery and faster service from the fire and police department. All property within the city shall post the address numbers of the property on a permanent mail box, building or plaque that is clearly visible from the street that the building faces. All address or building numbers shall be four inches in height and fluorescent and/or illuminated. In addition, the building number may be painted on the curb at each driveway entrance of the property with fluorescent paint as the background.

Historia

La línea de historia que la fuente imprime al final de la sección.

(Code 1996, § 82-122(a)—(h), (j)—(l); Ord. of 3-8-1999, pt. III, art. 15)

Leer este código donde se publica (Municode) La fuente es el código de la ciudad tal como lo publica su editorial o su propio sitio web. Consúltelo allí para ver cambios posteriores.

Versión local-code:bremen/zoning/120-67@2025-10-13-b9839193c0

El asistente puede decir lo que dice esta sección en esta edición, citándola y enlazándola. No aplicará la ley a su situación, y nada de esto es asesoría legal.

Bremen Zoning Ordinance, Sec. 120-67. General requirements | Georgia Commons