Brookhaven · Ordenanza de zonificación
Part II - CODE OF ORDINANCES / Chapter 27 - ZONING / Article XIII - TERMINOLOGY AND MEASUREMENTS / Division 2 - MEASUREMENT-RELATED TERMS
Sec. 27-1338. Height.
Sobre este texto
- As published by Municode, retrieved 2026-11-11
- The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.
Las notas de arriba, el texto de la sección y su línea de historia se muestran en inglés, tal como los publica la fuente y como los da el corpus.
(a) Building height.
(1) Measurement in feet.
a. When expressed as a regulation in "feet," building height is measured from average grade along all sides of the building to the highest point of the coping of a flat roof; to the deck lines of a mansard roof; or to the mean height level between the eaves and ridge of a gable, hip, or gambrel roof.
b. Except in the /AE overlay district, chimneys, elevators, equipment penthouses, belfries, clock towers, cupolas, spires and similar non-habitable structures and features may exceed maximum building height limits that are expressed in feet, provided such features cover no more than 25 percent of the total roof area of the building.
(2) Residential infill and redevelopment.
a. The proposed front door threshold elevation for any new detached house may not be more than two feet higher than the front door threshold elevation of the residential structure that existed on the lot prior to demolition. If the proposed construction would require alteration or eradication of the original threshold, then the original threshold elevation must be measured and certified by a licensed surveyor or engineer.
b. The community development director is authorized to approve proposed front door threshold elevations for new detached houses that exceed the threshold elevation allowed by subsection (2)a if the applicant for a building permit establishes that the elevation of the front door threshold of the proposed residential structure does not exceed the average elevation of the front door thresholds of the residential structures on both lots immediately abutting the subject lot. When using threshold height averaging, the applicant must provide the community development director with the threshold elevations, as certified by a licensed surveyor or engineer.
(3) Measurement in stories.
a. A building "story" includes any portion of a building, other than a basement, included between the surface of any floor and the surface of the floor next above or, if there is no floor above, the space between the floor and the ceiling next above.
Each floor or level in a multistory building used for parking, excluding a basement, is considered a story.
b. When building height regulations are expressed in terms of building "stories," headhouses, mechanical equipment normally built above the roof and not designed or used for human occupancy and roof structures that are completely open on at least three sides are not counted as stories. Any enclosed structure that is designed or used for human occupancy is counted as a "story" if the total area of such enclosed structures exceed in the aggregate: 330 square feet if the total roof area of the building is 3,300 square feet or less; or ten percent of the total roof area of the building if the total roof area is greater than 3,300 square feet.
c. Minimum and maximum story (floor-to-floor) heights shall be met along all street facing facades and for at least 75 percent of the floor area of each story.
d. In measuring building height, stories with a floor-to-floor height of 18 feet or greater are counted as two stories.
Figure 13-8. Building Height (in Feet)
e. The following requirements apply to all building types required to be at least two stories in height:
1. The second story floor area shall be covered and enclosed and equal at least 75 percent of the first story floor area;
2. The second floor facade shall extend the entire width of any first floor building facade that fronts on Peachtree Road or Apple Valley Road, except for second story areas used for unenclosed or uncovered outdoor dining area, uncovered decks, uncovered balconies, unenclosed stairs and uncovered atriums; and
3. The entire indoor area of the second floor shall be conditioned space (HVAC) and available for human occupancy.
f. Building types subject to minimum overall height limits shall meet the applicable minimum height requirement along street-facing facades for a depth of at least 30 feet into the building.
g. Maximum overall building height limits apply to the entire building.
(b) Retaining wall height. Retaining wall height is measured vertically from the finished grade on the exposed side of the retaining wall to the highest point of the wall.
(c) Height of other structures. The height of structures other than buildings and retaining walls is measured as vertical distance from the average finished grade on all sides at the base of the structure to the highest point of the structure.
Historia
(Ord. No. RZ-2018-11-06, § I, Exh. A(27.428), 11-27-2018; Ord. No. 2019-05-03, § I(Attch.), 5-28-2019)