Ir al contenido
Georgia Commons
Menú

Bryan County · Ordenanza de zonificación

Part II - CODE / Part B - LAND DEVELOPMENT / Chapter 114 / Article VI - SITE DEVELOPMENT STANDARDS / Division 5 - LANDSCAPING, TREE PRESERVATION, BUFFERING AND SCREENING

Sec. 114-629. Buffers required.

Sobre este texto

  • As published by Municode, current through 2026-01-13
  • The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.

Las notas de arriba, el texto de la sección y su línea de historia se muestran en inglés, tal como los publica la fuente y como los da el corpus.

(a) Purpose and applicability. Buffers are intended to retain the rural character of Bryan County and to minimize negative impacts between abutting developments. Buffers are required:

(1) Along the perimeter boundaries of major subdivisions;

(2) Along arterial and collector street frontage for all major subdivisions and for developments requiring site plan approval; and

(3) Along the boundaries between properties in different zoning districts at the time of subdivision and site plan development.

(b) Subdivision boundary buffers. The outer perimeter buffers around major subdivisions shall be at least 30 feet in depth. If other buffer requirements conflict with the minimum depth of this paragraph, the greater standard shall apply. Such buffers may be platted as part of lots for development for agricultural, multi-family, mixed-use, and non-residential subdivisions, but must be on a separate lot for residential development in a RR or R district. The same buffer requirement applies to any parcel being zoned to a commercial, business or industrial use.

(c) Arterial and collector road buffers. Any major subdivision or development requiring site plan approval that abuts an arterial or collector street shall provide a buffer along the street meeting the following requirements.

(1) Minimum buffer depth shall be:

a. One-hundred feet along an arterial road for a subdivision in an RR, R-15, RM or R-MH, or PD zoning district;

b. Fifty feet along an arterial road for a development in B-1, B-2, C-I, I-1, I-2, or P/I district;

c. Thirty feet along collector roads; and

d. For the WP district, the minimum buffer shall comply with the standards identified in article V, division 5, section 114-520(d).

(2) Buffer design shall comply with the provisions of section 114-630.

(3) Subdivision and site entrances and driveways may traverse required buffers.

(4) For industrial or commercial retail or service uses, the applicant may request to develop a streetyard as provided in section 114-631 instead of a buffer. The community development director may approve such request if the streetyard would maintain the character areas and fulfill the purposes identified in section 114-626(a).

(d) Buffers between land uses and zoning districts. At the boundaries of different zoning districts, between certain land uses, or between uses within planned developments that are only authorized in different zoning districts (e.g., between single family residential and multi-family residential or between non- residential and residential uses), buffers shall comply with the minimum requirements established in Exhibit 629 and the design requirements of section 114-630. Where Exhibit 629 specifies more than one applicable buffer type for the proposed development, the widest required buffer applies.

Exhibit 629: Minimum Buffer Widths Between Land Uses and Zoning Districts Land Use or Zoning District of

Proposed Development Adjacent Land Use or Zoning of Abutting Development A RR, R-15, or

RMH

RM or B-1 B-2 or C-I I-1, I-2 or P/I PD WP Detached Single-Family or Duplex Townhouse Multi-Family A None None None None None None None None None None R-R or R-15 50' 30' 30' 40' 40' 30' 40' 30' 30' 30' RM 50' 40' (with berm), or 100' (without berm) None None 30' 30' 30' 75' None None RMH See Section 114-737 B-1 50' 40' None None 30' 30' 30' 40' None None B-2 or C-I 50' 40' None None 20' 40' 20' 40' None None I-1 or I-2, Type A (see Exhibit 630b) 75' 75' 50' 30' None 50' None 75' 50' 50' I-1 or I-2, Type B (see Exhibit 630b) 50' 50' 40' 20' None 40' None 50' 40' 40' I-1 or I-2, Type C (see Exhibit 630b) 40' 40' 30' 15' None 30' None 40' 30' 30' P/I 50' 40' 30' 20' None 40' None 75' 50' 50' PD1 50' 50' 30' 40' 40' 30' 40' 50' 30' 30' WP 200' 200' 200' 200' 200' 200' 200' 200' 200' 200' Major Subdivision, Detached Single-Family or Duplex 50' 50' 30' 40' 40' 30' 40' 50' 30' 30' Major Subdivision, Townhouse 50' 75' None None 30' 30' 30' 75' None None Land Use or Zoning District of Proposed Development Adjacent Land Use or Zoning of Abutting Development A RR, R-15, or

RMH

RM or B-1 B-2 or C-I I-1, I-2 or P/I PD WP Detached Single-Family or Duplex Townhouse Multi-Family Multi-Family Development 50' 75' None None 30' 30' 30' 75' None None 1 The buffer standard may be modified during the PD approval process.

Historia

La línea de historia que la fuente imprime al final de la sección.

(Ord. No. 06-2020, § 3, 12-8-2020; Ord. No. 18-2022, § 3, 12-13-2022)

Leer este código donde se publica (Municode) La fuente es el código de la ciudad tal como lo publica su editorial o su propio sitio web. Consúltelo allí para ver cambios posteriores.

Versión local-code:bryan-county/zoning/114-629@2026-01-13-7267a584e8

El asistente puede decir lo que dice esta sección en esta edición, citándola y enlazándola. No aplicará la ley a su situación, y nada de esto es asesoría legal.

Bryan County Zoning Ordinance, Sec. 114-629. Buffers required | Georgia Commons