Buena Vista · Ordenanza de zonificación
Appendix A - ZONING / Article XI - OTHER REQUIREMENTS BY DISTRICT
Article XI. OTHER REQUIREMENTS BY DISTRICT
Sobre este texto
- As published by Municode, retrieved 2026-11-11
- The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.
Las notas de arriba, el texto de la sección y su línea de historia se muestran en inglés, tal como los publica la fuente y como los da el corpus.
Sec. A-110. Area, yard and height requirements.
This section is established to identify the minimum lot size and width, front and side yard setback, and building height allowed within each designated district.
Minimum Lot Size Minimum Front Yard from Right-of-Way of Street (feet) District Lot Area w/ Public Sewer (sq. feet) Lot Area w/ Septic Tank (feet) Lot Width at Building Line (feet) Major Streets All Other Streets Minimum Side Yards (feet) Minimum Rear Yard (feet) Maximum Height (feet) R-1 9,000 20,000 75 30 25 10 on each side 20 35 R-2 6,500 20,000 60 30 25 10 on each side 20 35 R-3 3,000 20,000 60 30 25 10 on each side 20 35 R-MH 10,895 20,000 75 30 25 40 on each side 40 40 R-AG 3 acres 3 acres 75 40 30 40 on each side 40 40 C-1 30 25 None, 10 if provided 30 40 C-2 30 25 None, 10 if provided 40 C-3 None None None 30 50 I-1 50 35 30 35 80 I-2 50 35 30 35 120 Sec. A-111. Private development maintenance.
111.1. Purpose. The purpose of this section is to promote the health, safety, morals and general welfare of the inhabitants of Buena Vista, Georgia, by regulating the occupancy and maintenance of manufactured home parks, travel trailer parks, apartments, planned unit developments (PUD) and all other developments with privately maintained infrastructure.
111.2. Definitions. When used in this section, the following words and phrases shall have the meaning given. The words not defined below shall have the meaning given in section A-31.
(1) Common area. Any area or space designed for joint use of tenants occupying the private development.
(2) Density. The number of dwellings per gross acre.
(3) Driveway. A private way used by vehicles and pedestrians on a private development or for common access to a group of lots or common facilities.
(4) Governing authority. Means the Mayor and City Council of the City of Buena Vista, Georgia.
(5) Management. The person who owns or has charge, care or control of the private development.
(6) Occupied area. That area of an individual lot which has been covered by a dwelling and its accessory structures.
(7) Private development. Any development in which the infrastructure (water and sewer mains, streets, driveways, etc.) is not owned by the City of Buena Vista.
Private development shall include, but is not limited to, apartment complexes, manufactured home parks, private retirement communities, and condominiums.
(8) Service building. A structure housing sanitary, operational, office, recreational, maintenance and other facilities built to conform to required standards.
(9) Sewer connection. Pipes, fittings and appurtenances from the drain outlet of the structure to the inlet of the corresponding sewer riser pipe of the sewer system serving the private development.
(10) Travel trailer park. An area where one or more travel trailers can be parked, designed or intended to be used as temporary living quarters for one or more families and intended primarily for automobile transi[ents] whether or not a charge is made for such accommodation.
(11) Water connection. Pipes, fittings and appurtenances from the water riser pipe to the water inlet pipe of the distribution system within the structure.
111.3. Permits required. It shall be unlawful for any person to construct, alter or extend any private development within the limits of Buena Vista, Georgia, unless the Zoning Enforcement Officer issues a valid permit after approval of the City Council.
Construction must begin within 180 days after issuance of the permit.
111.4. Applications. All applications for permits for private developments shall be submitted to the Zoning Enforcement Officer of Buena Vista, Georgia, after submission and approval of the final site plan.
111.4.1. Site plan. A private development site plan layout shall be drawn at a scale no smaller than 100 feet to one inch and shall show the following information:
(1) Five black or blue line prints of the final site plan shall be submitted and shall contain the following information:
(a) Name and address of applicant.
(b) Name and address of the owner of the land.
(c) Location (vicinity map) and legal description of the private development.
(d) North arrow.
(e) The area and dimensions of the tract of land.
(f) The number, location and size of all lots.
(g) The location, width and area of roadways, parkways, streets, driveways and walks.
(h) The location of service buildings and any other proposed structures.
(i) Location and design of parking spaces.
(j) Gross density.
(2) Approval of the final site plan shall be noted on all five prints and attested to by the signature of the Clerk of the City Council. Three prints shall be returned to the applicant, and two prints retained in the files of the Zoning Enforcement Officer.
Before acting on the site plan layout, the Commission may request a report from any person or agency directly concerned with the proposed development, such as the District Highway Engineer, Superintendent of Schools, and Public Utilities. Such reports shall certify compliance with or note deviations from the requirements of this chapter and include comments on other factors which bear upon the public interest. The responsibility of securing said reports is that of the Zoning Enforcement Officer.
Any time after approval of the final site plan by the Commission, application may be made for a permit for the construction of the private development. Five complete sets of construction plans shall be submitted to the Zoning Enforcement Officer and the Zoning Commission:
(1) The approved final site plan.
(2) Location of water and sewer lines and user pipes and manholes.
(3) Plans and specifications of the water supply, sewer lines, storm drainage system, refuse and sewerage disposal facilities.
(4) Plans and specifications of all buildings to be constructed, altered or extended within the private development.
(5) The location and details of lighting and electrical systems.
Upon review of the application the Zoning Enforcement Officer and the Zoning Commission shall issue a permit when a review of the application and inspection of the site demonstrates that the proposed or existing private development meets the requirements of this chapter.
111.5. Revocation of permits. Any permit for a private development may be revoked when it is found to be in violation of this chapter.
(1) Should the Zoning Enforcement Officer find that conditions exist which are in violation of any provision of this section, he shall give notice to the permittee or owner that, unless such conditions or practices are corrected within 30 days, the permit will be revoked.
(2) If at the end of 30 days, a further inspection reveals that the conditions or practices have not been corrected, the Zoning Enforcement Officer shall then revoke the permit and give notice of such suspension in writing to the permittee or owner. Upon notice of revocation, the permittee or owner shall cease operation and/or construction of the private development.
Leer este código donde se publica (Municode) La fuente es el código de la ciudad tal como lo publica su editorial o su propio sitio web. Consúltelo allí para ver cambios posteriores.