A. Monument signs.

1) Monument signs shall be constructed with a brick or stone base and frame within which advertising panels are contained.

2) The ground mounted base shall be equal to or greater than the length of the sign face including the cabinet or any other structure within which the sign is located.

3) The base shall be 18 to 24 inches high.

4) The use of exposed poles in ground signs is prohibited.

B. Wall signs.

1) A wall sign shall not extend more 12 inches beyond the facade of the building where attached.

2) The height of a wall-mounted sign shall not interfere, impede, or cause injury to pedestrian traffic.

3) Wall signs shall be limited to the following size (square footage and height), as shown in table 103-5:

Table 103-5 Wall Sign Size Requirements Primary or Secondary Building Frontage/Linear Feet Max. Square Footage per One Linear Foot of Building Frontage Max. Letter Height/Inches 0—40 2.0 36 40.01—60 2.0 40

60.01 + 2.0 48

C. Projecting and Swinging Signs. Projecting and swinging signs attached to a building shall meet the following requirements:

1) The maximum number of faces is two, with a total sign area of eight square feet per side.

2) The minimum clearance from the sidewalk to the bottom of the sign shall be ten feet with a maximum height not to exceed 22 feet when measured from the sidewalk, but in no case shall it be located or extend above the first floor.

3) In no case shall the sign extend above the roofline of the building nor extend more than four feet from the surface of the building.

4) Signs shall be attached to the building utilizing a decorative metal bracket. All brackets shall be painted flat black, only.

D. Awnings and awning signs.

1) The awning shall be located below the storefront cornice or sign panel.

2) Awning sign letters shall not exceed eight inches in height and shall be designed as an integral part of the awning design.

3) The awning valance shall not extend greater than seven feet from the building.

4) The awning shall not cover the piers on either side of the storefront.

E. A-frame signs.

1) The maximum number of faces is two, with a total sign area of eight square feet per side.

2) A-frame signs shall be located against the building facade, as to maintain a minimum of 48 inches of clear walking path along the public sidewalks.

3) A-frame signs shall be located only along the primary roadway, within the horizontal boundary created by the extents of the building frontage.

F. Digital message signs.

1) The messages displayed must be complete in themselves, without continuation in content to the next image or message or to any other sign.

2) Display of message must be static. When the display changes, it must change with no phasing, rolling, scrolling, flashing, twirling, blending, or in any manner which imitates movement.

3) Signs shall change no more than one time per hour.

4) Text messages shall be composed of one color with the background composed of one color.

Pictures, logos, images, graphics, and symbols may be displayed from one color to full color.

5) Signs shall be equipped with both a dimmer control and a photocell that automatically adjusts the display's intensity according to natural ambient light conditions.

6) Prior to issuance of a sign permit for an electric sign, the applicant shall provide written certification from the sign manufacturer that the light intensity has been factory pre-set not to exceed 15-foot candles measured four feet perpendicular to any surface of the electronic sign.

7) No sign shall display light of such intensity or brilliance to cause glare or otherwise impair the vision of the driver or result in a nuisance to the driver.

8) No sign shall be of such intensity or brilliance that it interferes with the effectiveness of an official traffic sign, device, or signal. Lighting shall not be used that may be mistaken for police or other emergency vehicles.

Historia

La línea de historia que la fuente imprime al final de la sección.

(Ord. No. 2014-18, § 2, 8-21-2014; Ord. No. 2019-0117-03, 1-17-2019)