All grading and clearing on lots shall conform to the following standards and provisions unless where otherwise recommended in an approved soil engineering, engineering geology, hydrology, or tree protection plan where the alternate procedures will be equal or superior in achieving the purposes of this UDC. In addition, the following standards and provisions shall be the governing criteria for the issuance or denial of land disturbance permits under this UDC.

A. Grading regulations.

1. Slopes shall be no steeper than two to one (2:1).

2. For slopes steeper than three to one (3:1), a slope revegetation plan must be submitted. Three to one (3:1) slopes shall require jute/coconut matting and will require additional vegetation in addition to matting (shrubs, junipers, etc.).

3. Slopes shall not exceed 20 feet in vertical height unless horizontal benches are installed at least every ten feet with five feet in depth.

4. All slopes greater than four to one (4:1) shall be located on one parcel. The top of the slope shall be no closer than one foot plus 50 percent of the height of the slope to an adjacent property owner but no less than five feet.

5. All fill slopes greater than ten feet shall be placed, compacted, inspected and tested and compaction results submitted to the community development department.

a. Ninety-five percent of maximum density.

b. A field density test shall be taken for each 18 inches of fill and for each 500 cubic yards of fill placed. For subdivisions, at least one field density test shall be taken on each lot which receives fill. One field density test shall be taken on the slope face for every four feet in elevation of the slope or every 1,000 square feet of slope for each lot.

6. All fill lots shall be noted on the final plat, with reference made to the applicable compaction report.

7. An engineer's report may be required for sensitive areas or areas of repeated slope failure, at the discretion of the community development director.

Historia

La línea de historia que la fuente imprime al final de la sección.

(Ord. No. 2019-0620-01, 6-20-2019)