A. Steel casing pipe shall be used for all cased piping where the carrier pipe is eight inches or greater in size.
B. Steel casing pipe shall have minimum yield strength of 35,000 psi and shall conform to the requirements of ASTM A139. It shall be fully coated on the exterior and interior with a coal tar coating. The casing pipe diameter shall be six to eight inches greater than the "bell" diameter of the carrier pipe. Minimum wall thickness shall be as shown in table 111-4.
Table 111-4 Minimum Wall Thickness (Steel Casing Pipe) Nominal Diameter, inches Nominal Thickness, inches Under 14 0.188 14 0.219 16 0.219 18 0.250 20 0.281 22 0.312 24 0.344 26 0.375 28 0.406 30 0.406 32 0.438 34 0.469 36 0.469 42 0.500 48 0.625 54 0.750 (Ord. No. 2014-18, § 2, 8-21-2014)
Leer este código donde se publica (Municode) La fuente es el código de la ciudad tal como lo publica su editorial o su propio sitio web. Consúltelo allí para ver cambios posteriores.