Ir al contenido
Georgia Commons
Menú

Carrollton · Ordenanza de zonificación

Appendix B - ZONING (RESERVED) / Article 4 - DESIGN STANDARDS

4.02.04. Design Standards for Industrial Development

Sobre este texto

  • As published by Municode, current through 2025-11-03
  • The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.

Las notas de arriba, el texto de la sección y su línea de historia se muestran en inglés, tal como los publica la fuente y como los da el corpus.

The following standards shall apply to development within the M-1 and M-2 zoning districts.

A. Architectural Standards.

1. Orientation. Buildings shall have their primary orientation toward the street.

2. Buildings or portions of buildings that are not put to industrial uses and instead are put to commercial uses or that are open to the general public (e.g., lobbies, reception areas, etc.) are subject to the following standards:

a. Buildings shall incorporate arcades, roofs, alcoves, porticoes, and/or awnings at public entrances that protect pedestrians from rain and sun.

b. Any wall adjacent to the street shall have a minimum of thirty (30) percent in windows, display areas, and entrances. Building frontages greater than [one hundred] 100 feet in length shall have offsets and other distinctive changes in building facades.

c. Buildings shall incorporate lighting and changes in mass, surface and finish giving emphasis to entrances.

3. Building materials. The following standards apply to buildings that are open to the public:

a. Building facades for buildings visible from the front or side yard adjacent to a street may not be clad in metal siding, plain concrete block, or plain concrete walls.

b. Permitted materials for these facades include, without limitation, brick, natural decay resistant wood siding, rock, stone, decorative concrete block or concrete walls with textured surface materials, and hardi-board. Vinyl lap siding may not be used.

c. Facade colors shall be earthtone or neutral. Building trim and accent colors areas may feature brighter colors, not to exceed twenty-five (25) percent of any building facade.

Leer este código donde se publica (Municode) La fuente es el código de la ciudad tal como lo publica su editorial o su propio sitio web. Consúltelo allí para ver cambios posteriores.

Versión local-code:carrollton/zoning/4.02.04@2025-11-03-19f1137cd9

El asistente puede decir lo que dice esta sección en esta edición, citándola y enlazándola. No aplicará la ley a su situación, y nada de esto es asesoría legal.

Carrollton Zoning Ordinance, 4.02.04. Design Standards for Industrial Development | Georgia Commons