A. Height regulations. Buildings shall not exceed a height of forty-five (45) feet or three and one-half (31 /2) stories, whichever is higher.
B. Minimum lot width. As specified in conditions of zoning.
C. Minimum development frontage: Sixty (60) feet.
D. Minimum lot frontage. As specified in conditions of zoning.
E. Minimum perimeter setback of entire development. As specified in conditions of zoning.
F. Minimum interior setbacks. As specified in conditions of zoning.
G. Accessory structure requirements. See section 4.9 of this chapter.
H. [Metal panels, metal sheathing, standard gray concrete block.] The use of metal panels or metal sheathing and/or standard gray concrete block on the exterior walls of any building or structure shall be
prohibited with the exception that such materials may be used if finished with a product consisting of brick, stone, or hardcoat stucco.
I. [Gable or hip roofs.] Gable or hip roofs shall have a minimum roof pitch of 6/12.
Both gable and hip roofs shall provide overhanging eaves on all sides that extend a minimum of one (1) foot beyond the building wall.
J. Minimum buffer requirements. In addition to required setbacks, all uses within the PC-D district which abut a singlefamily residential district or use shall provide a minimum fifteen-foot wide buffer, five (5) feet of which can be within required setback, to provide a visual screen
in accordance with section 4.17 of this chapter.
K. [Air conditioning units and HVAC systems.] Air conditioning units and HVAC systems shall be thoroughly screened from
view from the public right-of-way and from adjacent properties by using walls, fencing, roof elements, or landscaping on multifamily and nonresidential properties.
L. [Front building facade.] The front building facade of all principal buildings shall be oriented toward street fronts or adjacent arterial street fronts.
M. [Refuse areas.] Refuse areas (dumpsters) shall be placed in the least visible location from public streets, and shall be enclosed on three (3) sides with opaque walls, with the fourth side being an opaque closing gate. Height of an opaque wall shall be at least twelve (12) inches higher than the receptacle.
N. [Light fixture poles.] Light fixture poles cannot exceed forty (40) feet in height. All site lighting shall be directed onto the site.
O. [Chain link fences.] Chain link fences are not allowed in the front yards. Where allowed, all chain link fences shall not be taller than five (5) feet in height and shall be vinyl coated, with one (1) of the following colors: hunter green or black.
P. Building massing. Street fronting building facades greater than one hundred fifty
(150) feet in length shall be modulated with breaks in wall surfaces and materials at intervals not to exceed one hundred fifty (150) feet, measured parallel to the
street. For buildings that are three (3) stories or less in height, each floor shall be delineated through windows, belt courses, cornices lines, or similar architectural detailing.
Q. Color. Fluorescent colors shall not be employed except as accent colors.