A. Height regulations. Single-family residential buildings shall not exceed a height of thirty-five (35) feet or two and one-half (21

/2) stories, whichever is higher;

multifamily and nonresidential buildings shall not exceed a height of fortyfive (45) feet or three and one-half (31 /2)

stories, whichever is higher.

B. Front yard setback: Ten (10) feet.

C. Side yard setback: Ten (10) feet.

• If single-family attached, ten (10) feet end of each row.

D. Rear yard setback:

• Office/institutional/commercial:

Twenty (20) feet.

• Multifamily: Twenty-five (25) feet.

• Townhouse: Twenty (20) feet.

• Single-family attached: Twenty (20) feet.

• Single-family detached: Twenty (20) feet.

• Duplex dwellings: Twenty (20) feet.

E. Minimum lot area.

• Townhouse/attached: Two thousand (2,000) square feet.

• Single-family detached and duplex dwellings Seven thousand (7,000) square feet.

F. Maximum density.

• Multifamily: Fourteen (14) dwelling units per acre.

• Townhouse/attached: Twelve (12) dwelling units per acre.

G. Minimum lot width at building line.

• Office/institutional/commercial:

One hundred ten (110) feet per lot.

• Multifamily: One hundred ten (110) feet.

• Townhouse: Twenty (20) feet per lot.

• Single-family attached: Fifty (50) feet per lot.

• Single-family detached: Sixty (60) feet per lot.

• Duplex dwellings: Fifty (50) feet per lot.

H. Minimum lot frontage.

• Office/institutional/commercial:

One hundred ten (110) feet per lot.

• Multifamily: One hundred ten (110) feet per lot.

• Townhouse: Twenty (20) feet per lot.

• Single-family attached: Fifty (50) feet per lot.

• Single-family detached: Sixty (60) feet per lot.

• Duplex dwellings: Thirty-five (35) feet per lot.

I. Minimum heated floor area per dwelling unit.

• Multifamily:

� 3-bedroom: Nine hundred (900) square feet.

� 2-bedroom: Seven hundred fifty

(750) square feet.

� 1-bedroom: Six hundred (600) square feet.

� Studio/loft (in existing buildings): Four hundred fifty (450) square feet.

• Townhouse/attached: One thousand (1,000) square feet.

• Single-family detached: One thousand (1,000) square feet.

• Duplex: Nine hundred (900) square feet.

J. [Metal panels, metal sheathing, standard gray concrete block.] The use of metal

panels or metal sheathing and/or standard gray concrete block on the exterior walls of any building or structure shall be

prohibited with the exception that such materials may be used if finished with a product consisting of brick, stone, hardcoat stucco, or fiber cement siding.

K. [Air conditioning units and HVAC systems.] Air conditioning units and HVAC systems shall be thoroughly screened

from view from the public right-of-way and from adjacent properties by using walls, fencing, roof elements, or landscaping on multifamily and nonresidential properties.

L. [Gable or hip roofs.] Gable or hip roofs shall have a minimum roof pitch of 6/12.

Both gable and hip roofs shall provide overhanging eaves on all sides that extend a minimum of one (1) foot beyond the

building wall.

M. [Front building facade.] The front building facade of all principal buildings shall be oriented toward street fronts or

adjacent arterial street fronts.

N. Minimum buffer requirements. In addition to required setbacks, all nonresidential and/or multifamily

property uses within the M-U district which abut a single-family residential district or use shall provide a minimum fifteen-foot wide buffer, five (5) feet of which can be within required setback, to provide a visual screen in accordance

with section 4.17 of this chapter.

O. Minimum open space. Multifamily developments shall have a minimum twenty (20) percent of gross acreage set aside as open space and shall provide

recreational areas within said open space.

P. Maximum commercial building floor area:

Twenty thousand (20,000) square feet.

Q. Accessory structure requirements. See section 4.9 of this chapter.

R. Other standards.

1. Townhouse developments shall have a minimum development area of one-half (1 /2) acre. In addition to required setbacks, a fifteen-foot wide buffer is required along all property lines which abut a single-family district or use to provide a visual screen in accordance with section

4.17 of this chapter.

(a) Minimum lot depth: one hundred (100) feet.

(b) No fewer than three (3) dwelling units in a row shall be allowed.

(c) Alley or private drive access required.

(d) Required parking shall be allowed in the rear yard only.

(e) Principal buildings shall front a private drive or public rightof-way.

2. Multifamily developments shall comply with section 7.1.3.K. and N.

of this chapter.

3. Outdoor storage of landscape supplies and materials may be allowed in the side and rear yards of a

non-residential land use with a special use (SU) permit.

S. Guest house. In addition to standards required in this chapter, the following

standards shall be met for a guest house:

1. No more than one (1) guest house structure per lot.

2. A minimum lot size of fifteen thousand (15,000) square feet shall be required.

3. A guest house shall be occupied by relatives, employees that work on the property, or guests only.

4. Heated floor area shall not exceed fifty (50) percent of the heated floor area of the principal building.

5. A guest house structure shall comply with the principal setbacks of the district.

6. A guest house shall not be allowed in the front yard.

7. A guest house shall not exceed the height of the principal building on the lot.

8. Requires owner-occupancy of the principal building on the lot.