Ir al contenido
Georgia Commons
Menú

Cartersville · Ordenanza de zonificación

Part - CODE OF ORDINANCES / Part 1 - EXISTING STRUCTURES: / Chapter 26 - ZONING TABLE OF CONTENTS / Article IX - COMMERCIAL DISTRICT REGULATIONS

9.3.3. Development standards.

Sobre este texto

  • As published by Municode, retrieved 2026-11-11
  • The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.

Las notas de arriba, el texto de la sección y su línea de historia se muestran en inglés, tal como los publica la fuente y como los da el corpus.

A. Height regulations. Buildings shall not exceed a height of forty-five (45) feet or three and one half (31 /2) stories, whichever is higher.

B. Front yard setback: Twenty (20) feet.

C. Side yard setback: Ten (10) feet.

D. Rear yard setback: Twenty (20) feet.

E. Minimum lot area. None.

F. Minimum lot frontage: One hundred ten

(110) feet adjoining a street.

G. Minimum lot width at the building line:

One hundred ten (110) feet.

H. Minimum heated floor area per dwelling unit.

• 3-bedroom: Nine hundred (900) square feet.

• 2-bedroom: Seven hundred fifty (750) square feet.

• 1-bedroom: Six hundred (600) square feet.

• Studio/loft (in existing buildings):

Four hundred fifty (450) square feet.

I. Minimum buffer requirements. In addition to required setbacks, a minimum fifteen-foot wide buffer, five (5) feet of

which can be within required setback, shall be required along all property lines which abut a residential district or use to provide a visual screen in accordance

with section 4.17 of this chapter.

J. [Metal panels, metal sheathing, standard gray concrete block.] The use of metal

panels or metal sheathing and/or standard gray concrete block on the exterior walls of any building or structure shall be prohibited with the exception that such materials may be used if finished with a product consisting of brick, stone, or hard-coat stucco.

K. [Air conditioning units and HVAC systems.] Air conditioning units and HVAC systems shall be thoroughly screened from view from the public right-of-way and from adjacent properties by using walls, fencing, roof elements, or landscaping on multifamily and nonresidential properties.

L. [Gable or hip roofs.] Gable or hip roofs shall have a minimum roof pitch of 6/12.

Both gable and hip roofs shall provide overhanging eaves on all sides that extend a minimum of one (1) foot beyond the building wall.

M. [Front building facade.] The front building facade of all principal buildings shall be oriented toward street fronts or

adjacent arterial street fronts.

N. [Refuse areas.] Refuse areas (dumpsters) shall be placed in the least visible location from public streets, and shall be enclosed on three (3) sides with opaque

walls, with the fourth side being an opaque closing gate. Height of an opaque wall shall be at least twelve (12) inches higher than the receptacle.

O. [Light fixture poles.] Light fixture poles cannot exceed forty (40) feet in height.

All site lighting shall be directed onto the site.

P. [Chain link fences.] Chain link fences are not allowed in the front yards. Where

allowed, all chain link fences shall not be taller than five (5) feet in height and

shall be vinyl coated, with one (1) of the following colors: hunter green or black.

Q. Building massing. Street fronting building facades greater than one hundred fifty (150) feet in length shall be modulated with breaks in wall surfaces and materials at intervals not to exceed one hundred fifty (150) feet, measured parallel to the

street. For buildings that are three (3) stories or less in height, each floor shall be delineated through windows, belt

courses, cornices lines, or similar architectural detailing.

R. Color. Fluorescent colors shall not be employed except as accent colors.

S. Off-street parking.

1. Minimum number of off-street parking spaces: One (1) space per four hundred (400) square feet of gross

floor area.

2. Maximum number of off-street parking spaces: One (1) space per two hundred (200) square feet of gross

floor area.

T. Maximum commercial building floor area:

Fifteen thousand (15,000) square feet.

U. Accessory structure requirements. See section 4.9 of this chapter.

Leer este código donde se publica (Municode) La fuente es el código de la ciudad tal como lo publica su editorial o su propio sitio web. Consúltelo allí para ver cambios posteriores.

Versión local-code:cartersville/zoning/9.3.3@2026-11-11-f7307be85b

El asistente puede decir lo que dice esta sección en esta edición, citándola y enlazándola. No aplicará la ley a su situación, y nada de esto es asesoría legal.

Cartersville Zoning Ordinance, 9.3.3. Development standards | Georgia Commons