9.5.3. Development standards.
Sobre este texto
- As published by Municode, retrieved 2026-11-11
- The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.
Las notas de arriba, el texto de la sección y su línea de historia se muestran en inglés, tal como los publica la fuente y como los da el corpus.
A. Height regulations. Buildings shall not exceed a height of forty-five (45) feet or three and one-half (31
/2) stories, whichever is higher.
B. Front yard setback: Twenty (20) feet.
C. Side yard setback: Ten (10) feet.
D. Rear yard setback: Twenty (20) feet.
E. Minimum lot frontage: One hundred ten
(110) feet adjoining a street.
F. Minimum lot width at the building line:
One hundred ten (110) feet.
G. Minimum heated floor area per dwelling unit.
• 3-bedroom: Nine hundred (900) square feet.
• 2-bedroom: Seven hundred fifty (750) square feet.
• 1-bedroom: Six hundred (600) square feet.
• Studio/loft (in existing buildings):
Four hundred fifty (450) square feet.
H. Minimum buffer requirements. In addition to required setbacks, a minimum twenty-foot wide buffer, five (5) feet of which can be within required setback,
shall be required along all property lines which abut a residential district or use to provide a visual screen in accordance
with section 4.17 of this chapter.
I. Accessory structure requirements. See section 4.9 of this chapter.
J. [Metal panel exterior.] A metal panel exterior finish product shall not be allowed on metal buildings exceeding one hundred fifty (150) square feet in gross floor area constructed or placed on lots within the O-C district with the exception that such materials may be used if finished with a product consisting of brick, stone, or
hard-coat stucco.
K. [Air conditioning units and HVAC systems.] Air conditioning units and HVAC systems shall be thoroughly screened
from view from the public right-of-way and from adjacent properties by using walls, fencing, roof elements, or landscaping on multifamily and nonresidential properties.
L. [Gable or hip roofs.] Gable or hip roofs shall have a minimum roof pitch of 6/12.
Both gable and hip roofs shall provide overhanging eaves on all sides that extend a minimum of one (1) foot beyond the
building wall.
M. [Front building facade.] The front building facade of all principal buildings shall be oriented toward street fronts or
adjacent arterial street fronts.