Chamblee · Ordenanza de zonificación
Appendix A - UNIFIED DEVELOPMENT ORDINANCE / Title 3 - DEVELOPMENT AND PERMITTING / Chapter 340 - STORMWATER MANAGEMENT / Article 6 - GROUNDWATER RECHARGE AREA PROTECTION
Section 340-71. Groundwater protection standards.
Sobre este texto
- As published by Municode, retrieved 2026-11-14
- The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.
- Tables are shown as their rows, with the cells separated by a bar ( | ).
Las notas de arriba, el texto de la sección y su línea de historia se muestran en inglés, tal como los publica la fuente y como los da el corpus.
(a) For all pollution susceptibility areas, new waste disposal facilities must have synthetic liners and leachate collection systems.
(b) New agricultural impoundments shall meet the following requirements:
(1) For areas of high susceptibility, a liner shall be provided that is approved by the U.S. Soil Conservation Service (SCS).
(2) For areas of medium susceptibility, an SCS approved liner shall be provided if the site exceeds 15 acre-feet.
(3) For areas of low susceptibility, a SCS approved liner shall be provided if the site exceeds 50 acre-feet.
(c) No land disposal of hazardous waste shall be permitted within significant groundwater recharge area.
(d) For all significant groundwater recharge areas, the handling, storage and disposal of hazardous materials shall take place on impermeable surface having spill and leak protection approved by the Georgia Department of Natural Resources, Environmental Protection Division (EPD).
(e) For all significant groundwater recharge areas, new above ground chemical or petroleum storage tanks larger than 650 gallons must have secondary containment of 110 percent of tank volume or 110 percent of the largest tanks in a cluster of tanks.
(f) For high pollution susceptibility areas, new wastewater treatment basins shall have an impermeable liner approved by EPD.
(g) For high pollution susceptibility areas, no new stormwater infiltration basins may be constructed.
(h) For high pollution susceptibility areas, wastewater spray irrigation systems or the land spreading of wastewater sludge shall be practiced in accordance with Department of Natural Resources criteria for slow rate land treatment. An application for a development permit for activities involving wastewater spray irrigation or land spreading of wastewater sludge must be accompanied by proof that the applicant has received a land application system permit from EPD.
(i) New homes served by septic tank/drain systems shall conform to minimum lot size requirements identified in the Minimum Lot Size Requirements Table and Single-Family Home Minimum Lot Size Where Served by On-site Septic Tank Systems Table below:
Minimum Lot Size Requirements Table
- Pollution susceptibility | New homes served by septic systems
- High | 150% of minimum lot sizes specified in Single-Family Home Minimum Lot Size Where Served by On-Site Septic Tank Systems Table
- Medium | 125% of minimum lot sizes specified in Single-Family Home Minimum Lot Size Where Served by On-Site Septic Tank Systems Table
- Low | 110% of minimum lot sizes specified in Single Family Home Minimum Lot Size Where Served by On-site Septic Tank Systems Table
Source: DHR Manual for On-Site Sewerage Management Systems
Single-Family Home Minimum Lot Size Where Served\ by On-Site Septic Tank Systems Table
- Slope of lot (%) | Soil group 2 Dekalb County Well-drained to moderately well-drained soils with percolation rates from 10 to 30 min./in.
- Minimum lot size in square feet
- 0—5 | 39,000
- 5—15 | 42,000
- 15—25 | 45,000
- 25—35 | 48,000
Source: DHR Manual for On-Site Sewerage Management Systems
Historia
(Ord. No. 743, 12-19-17)
Leer este código donde se publica (Municode) La fuente es el código de la ciudad tal como lo publica su editorial o su propio sitio web. Consúltelo allí para ver cambios posteriores.