Clarkston · Ordenanza de zonificación
Appendix A - ZONING / Article III - ZONING DISTRICT REGULATIONS / Division 3 - NON-RESIDENTIAL DISTRICTS
Sec. 309. Dimensional Requirements.
Sobre este texto
- As published by Municode, retrieved 2026-11-11
- The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.
Las notas de arriba, el texto de la sección y su línea de historia se muestran en inglés, tal como los publica la fuente y como los da el corpus.
Dimensional requirements for non-residential zoning districts are established in Table 3.5, Non-Residential Zoning Districts Dimensional Requirements.
Buffer requirements on Table 5.3 also apply.
Table 3.5 Non-Residential Zoning District Dimensional Requirements
NC-1 NC-2 I* R-OS
Maximum
FAR
1 1 2 N/A Minimum Unit Size 700 s.f. 700 s.f. N/A N/A Maximum Lot Coverage 80% 80% 70% N/A Minimum Open Space
20% 20% N/A N/A
Maximum Building Height 3 stories/45' 3 stories/50' 50' N/A Minimum Lot Size 6000 s.f. 8,500 s.f. N/A N/A Minimum Lot Width
50' 75' N/A N/A
Minimum Front Setback 10' 10' 35' N/A Maximum Front Setback
N/A N/A N/A N/A
Minimum Side Setback 0'-8'** 0'-8'** 15' N/A Minimum Rear Setback 10'-20'*** 10'-20'*** 20' N/A *See Sec. 312 ** Side yard setback must be greatest distance when abutting a singlefamily residential district ***Rear yard setback must be of greatest distance when abutting a singlefamily residential district (Ord. No. 480, § 1, 6-6-23)
Leer este código donde se publica (Municode) La fuente es el código de la ciudad tal como lo publica su editorial o su propio sitio web. Consúltelo allí para ver cambios posteriores.