Sec. 46-61. Life and safety minimum requirements.

Sobre este texto

  • As published by Municode, retrieved 2026-11-11
  • The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.

Las notas de arriba, el texto de la sección y su línea de historia se muestran en inglés, tal como los publica la fuente y como los da el corpus.

The licensee shall comply with all fire and safety requirements as defined in city ordinance, NFPA 101 the Life Safety Code and the requirements of the Georgia Safety Fire Commissioner as defined in Chapter 120 and O.C.G.A § tit. 25 ch. 12.

The following shall be provided:

(1) Every sleeping quarters or bedroom shall be provided an operating fire detector that complies with the aforementioned code(s);

(2) Every unit or structure that utilizes fossil fuels or other substances that may cause carbon monoxide to collect within the short-term rental shall provide operational CO detectors as recommended by manufacturer;

(3) Each sleeping quarters or bedroom shall be equipped with at least one operable window or door that opens directly to the exterior of the structure and shall comply with the requirements of applicable code. The window shall have a clear opening of not less than 5.7 square feet. The width shall not be less than 20 inches, and the height shall not be less than 24 inches and shall comply with applicable code. The bottom of the window opening shall not be more than 44 inches above the floor;

(4) The door shall be the size and type that complies with applicable code;

(5) The door or window shall be operable from the interior and shall not require the use of tools, keys, special effort or strength and shall provide a full, clear opening;

(6) The window or door shall discharge to the exterior of the structure and shall provide a clear, level path to the public way or a place of safety that is distant to the structure;

(7) All floors above or below main level shall provide means of egress or escape that complies with code(s);

(8) Each short-term rental unit shall provide an approved fire extinguisher that complies with code as to the type and weight and be located no more than eight feet from a cooking area, fireplace, gas stove/fireplace or logs or any other device or area that provides the use of flame or extreme heat. Additionally, an extinguisher shall be located upon each floor of the rental property such are to be fully charged, satisfy expiration requirements, and meet all NFPA standards including those as set forth in NFPA 10: Standard for Portable Fire Extinguishers;

(9) Private swimming pools shall comply with the current International Swimming Pool and Spa Code and Georgia State Law;

(10) The owner and/or local contact person shall maintain 9-1-1 numbering upon the structure and at the roadway entrance to the property that has a minimum four-inch lettering, reflective and two-sided signage that is visible from both directions of travel upon the city street, to assist emergency responders to locate the rental.

Historia

La línea de historia que la fuente imprime al final de la sección.

(Ord. of 12-11-2018)