Development standards for any PD, including lot area, site dimensions, required yards, density, site coverage, landscaping and parking shall be explicitly proposed by the applicant and be approved by the mayor and council, provided such proposal does not fall below the standards of this Article.
A. Minimum tract size. The minimum size for any PD shall be ten (10) acres.
B. Public facilities. The applicant shall demonstrate that adequate public facilities will be provided to serve the PD. Such facilities at a minimum shall include, but not be limited to, water supply, sewage disposal, drainage control, roads, sidewalks and bike lanes. Any extension of public facilities shall be designated to avoid inefficiency, duplication, premature extensions, and unnecessary public costs. The applicant shall be solely responsible for installation of these public facilities in conformance with city standards and at the applicant's expense; provided that where such PD encompasses a portion of an Urban Redevelopment Area established by the mayor and council pursuant to the Urban Redevelopment Law, the city may elect, at its sole discretion, to joint venture in the cost and/or installation of public facilities where it determines such action is necessary to facilitate redevelopment of a blighted area.
C. Underground utilities. PDs must include underground installation of all utilities, including, at a minimum, telephone, electric power and cable television in both public and private right-of-way, except when extreme conditions of underlying rock or other conditions make this requirement unreasonable.
D. Construction standards. Streets, sidewalks, water supply, sanitary sewer and drainage structures shall be constructed in accordance with the Subdivision Regulations of College Park and design and construction standards adopted by the city, unless otherwise approved by the Engineering Director in accordance with standards established in Table II, below. The minimum right-of-way for all streets shall be fifty (50) feet. Entry streets accessing the PD and commercial streets shall be a minimum of twenty-eight (28) feet paved width for commercial streets.
Residential streets shall be a minimum of twenty-four (24) paved feet in width;
provided that where a PD proposes utilizing existing streets of lesser width, the pavement width may be reduced to twenty (20) feet curb to curb upon certification by the Engineering Director in consultation with other department heads that emergency vehicle access will not be impaired. Street width dimensions shall be subject to approval by the Engineering Director. A minimum height clearance of thirteen and one-half (13) feet shall be maintained over all streets. All streets shall have vertical curbs.
E. Sidewalks. Sidewalks shall be installed along the entire frontage of all developments. Sidewalks adjacent to residential properties shall be a minimum of four (4) feet in width; sidewalks adjacent to commercial properties shall be a minimum of ten
(10) feet in width. Pedestrian crosswalks shall be provided and clearly marked at intersections serving residential developments. Crosswalks serving commercial developments shall be identified through the use of pavement materials such as stone pavers which differentiate the crosswalk from the normal street surface.
Pedestrian crossing control devices shall be provided at all signalized intersections.
F. Parking regulations. Off-street parking requirements are as provided in Table I, below. Commercial parking requirements may be reduced provided that off-street parking which is specifically owned or leased by the property owner seeking the reduction is located within four hundred (400) feet, as measured along the sidewalk, of the use such parking is intended to serve.
All off-street parking proposed for a PD must comply with the landscape provisions of Article 9, Tree Protection of this ordinance. In addition, a landscaped area having a minimum width of ten (10) feet shall be installed between parking areas and residential units in attached dwelling developments.
Table I. Off-Street Parking Requirements Use Spaces Required Detached Dwelling Two (2) spaces per dwelling unit Attached Dwelling One and one-half (1) spaces per dwelling unit Retail Shop One space per three hundred (300) sq. ft. of net floor area Restaurant One space for every five (5) seats
Office One space per two hundred and fifty (250) sq. ft. of net floor area Table II. Lot and Dwelling Unit Dimensional Standards
Standard Detached Residential Townhouses Multifamily Minimum sq. ft. structure: One Bedroom & Efficiency 1,400 sq. ft. 800 sq. ft. 800 sq. ft.
Two Bedrooms 1,400 sq. ft. 1,000 sq. ft. 1,000 sq. ft.
Three Bedrooms 1,400 sq. ft. 1,200 sq. ft. 1,200 sq. ft.
Front Yard 10 ft. min. 0 0 Side Yard 1 2 foot min. 0 0 Rear Yard 2 0 foot min.
1. Side yard requirements shall meet all standards of city's building and fire safety codes.
2. Principal building only; no rear yard requirement when abutting an alley.
G. Minimum building separation. The following minimum building separation schedule shall apply to all multifamily residential and commercial development within a PD (other than the Downtown Historic District):
Front to Front 40 feet;
Front to Rear 40 feet;
Front to Side 35 feet;
Rear to Rear 40 feet;
Rear to Side 35 feet;
Side to Side 25 feet.
H. Signs. A uniform sign system shall be proposed by the applicant which constitutes an attractive, functional approach to conveying information to the public. All signs must be compatible with the architectural character of the PD and conform to the requirements of the College Park Zoning Ordinance. The developer shall incorporate sign restrictions into protective covenants running with the land. No sign shall exceed twenty-four (24) square feet in area, nor twelve (12) feet in height. Sign lighting shall be indirect.
I. Street Signs. Street sign systems may be proposed, subject to approval by the director of public works. The initial installation of such systems shall be at the developer's sole expense.
J. Buffers. Buffers shall be designed to visually screen incompatible uses, dumpsters, mechanical equipment and parking areas. Establishment and maintenance of all buffers shall conform to Article 9, Tree Protection of this ordinance and the schedule presented in Table III.
Table III. Buffer Width for Specified Abutting Uses
EXISTING USE PROPOSED USE
Detached Residential Attached Residential Office Retail Detached Residential None 20 feet 25 feet 30 feet Attached Residential 20 feet 15 feet 15 feet 15 feet Office 25 feet 20 feet 15 feet 15 feet Retail 30 feet 25 feet 15 feet None
K. Landscaping. A landscape plan demonstrating a functional treatment of exterior spaces, and providing ample quantities and varieties of plant materials regarded as suitable to the area climate, shall be provided. All landscape design, construction and maintenance shall comply with the provisions of Article 9, Tree Protection, of this ordinance and shall achieve the following objectives:
1. Produce an attractive, pleasant environment;
2. Achieve visual relief by softening structural mass and by screening parking and loading areas;
3. Provide open areas on-site as an amenity for residents and visitors; and
4. Foster use of indigenous plant materials to reflect the character and quality of surrounding areas.
L. Street Trees. Street trees shall be installed within the right-of-way of all public streets. Such plantings shall be accomplished at no greater distance than fifty (50) feet apart and shall consist of canopy trees. The following species are prohibited:
Eastern White Pine Black Willow Box Elder Royal Paulownia Lombardy Poplar Tree of Heaven Mimosa Water Oak Silver Maple Red and White Oaks Spruce
M. Lighting. All lighting shall be arranged to prevent direct glare or hazardous interference of any kind onto adjoining streets or property, or skyward, and shall conform to City of College Park Building Codes. Accent lighting designed to feature architectural or landscape elements shall be of such intensity as to illuminate such elements, only. Pedestrian scale lighting not to exceed sixteen (16) feet in height shall be provided as appropriate to the surrounding uses along all public streets.
Such lighting shall conform to the architectural design and character of the development.
N. Phasing plan. A development schedule for PD which is proposed for implementation over a series of distinct construction time periods shall be provided. Individual project phases must be whole and complete and maintain a workable, functioning and efficient relationship throughout the PD. No phase shall be approved which is dependent upon any future phase for road access, public facilities or services, parking or common open spaces.