Section 6.6.2. Design Requirements.

Sobre este texto

  • As published by Municode, retrieved 2026-11-11
  • The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.

Las notas de arriba, el texto de la sección y su línea de historia se muestran en inglés, tal como los publica la fuente y como los da el corpus.

The following are minimum requirements that apply to the layout of open space set aside to meet the minimum open space requirements of this Chapter and to those areas set aside to achieve "bonus" lots in a resource conservation subdivision.

A. Minimum Width. The minimum width of any open space area shall be 100 feet, as measured perpendicular to the centerline between the boundaries of the open space, except as noted below.

1. Natural Boundaries. Any portion of a Primary or Secondary Conservation Area that, by the very nature of its designated boundaries, is less than 100 feet in width. Examples include strips of steep slopes and "fingers" of floodplains that extend up drainage swales.

2. Parkways. Parkways between road travelways designated as Secondary Conservation Areas, which must be at least 26 feet in width.

3. Viewsheds. Viewshed buffers, if provided to screen the view of the subdivision development, must be at least 200 feet in width unless the topography of the land adequately screens the view of the buildings in the subdivision from the abutting roadway.

B. Minimum Size. The minimum size of any open space area shall be two acres of contiguous land, except as provided below.

1. Primary or Secondary Conservation Areas. A portion of a Primary or Secondary Conservation Area that adjoins the site and extends into the site covering an area of less than two acres.

2. Isolated Steep Slope. An isolated strip of steep slope, provided that such an area having a slope greater than 25% must comprise at least 5,000 square feet, and such an area having between 15% and 25% must comprise an area of at least 40,000 square feet.

3. Buffer Areas. Buffer areas around wetlands or habitats of endangered or threatened species, provided that the combination of the buffer area and the wetland or wildlife habitat must contain at least two acres of contiguous area.

4. Historic and Archeological Assets. Historic or archeological assets and specimen trees that can be adequately protected by an area of less than two acres.

5. Parkways. Parkways between road travelways that are limited in size due to intersecting roads.

C. Path and Street Crossings. Where path systems cross an internal subdivision street, the access points must be directly across from each other and clearly identified both to the motorist and pedestrian by signage and crosswalk striping. Where a path crosses any public road, the path must be grade separated (i.e., by a tunnel or bridge), or located at a traffic control device such as a regulated intersection or flashing light approved by the City.