Cordele · Ordenanza de zonificación
Appendix A - ZONING / Article IX - SIGNS
Section 960. Signs permitted in specific zoning districts.
Sobre este texto
- As published by Municode, retrieved 2026-11-11
- The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.
Las notas de arriba, el texto de la sección y su línea de historia se muestran en inglés, tal como los publica la fuente y como los da el corpus.
960.1 Generally. Except as otherwise provided for under this Article, any sign not specifically permitted in a zoning district as provided under this section, shall be prohibited in that district.
960.2 Tables of Allowable Signs. The following tables set forth the types of signs that are allowed upon issuance of a sign permit in accordance with section 920 above. Signs that require a conditional use permit are denoted in the footnotes.
Allowable Signs in Residential and Mixed Use Zones
(R-12, R-7.5S, R-7.5, R-4, MU)
Type of Sign Number of Signs Allowed Maximum Display Area per Sign Maximum Height Setback from Right-of-Way Permanent Wall - 1 per building;
Ground - 1 per building 16 sq. ft. (2) 6 feet 10 feet Temporary (4) Freestanding - 1 per lot;
Portable - 1 per lot (4) 20 sq. ft. 6 feet 10 feet
(1) Signs exceeding sixteen (16) square feet in area require a Conditional Use Permit from the Board of Zoning Appeals.
(2) There is no setback required for the construction of a double face sign in a median unless the Chief Codes Official determines such sign will constitute a traffic hazard in which case a Conditional Use Permit must be approved by the Board of Zoning Appeals.
(3) Temporary signs on the lot of a permitted non-residential use may be issued for a maximum of four (4) weeks. Such signs require a Conditional Use Permit to be used for a period longer than four (4) weeks.
Allowable Signs in Central Business District, Neighborhood Commercial, and Office/Professional District
(CBD, NC, & OI)
Type of Sign Number of Signs Allowed Maximum Display Area per Sign Maximum Height Setback from Right-of-Way Permanent Freestanding or projecting: 1 per building (2);
Wall - 5 per building (3) Freestanding - 100 sq. ft. (4);
Projecting - 20 sq.
ft.;
Wall (5) Freestanding - 30 ft. (4);
Projecting-(6);
Wall - No higher than top of wall Freestanding - 10 ft. (4) Temporary Freestanding - 1 per business;
Portable - 1 per business 25 square feet 6 feet (4) 10 feet
(1) Projecting signs can not project more than six and one-half (61 /2) feet from the wall and
may be located not closer than eighteen (18) inches to a vertical plane at the street curb line.
(2) Wall signs shall not project more than twenty-four (24) inches beyond the wall.
(3) Signs that do not comply with these limits must obtain a Conditional Use Permit.
Free-standing signs that are closer than one hundred (100) feet from another free-standing sign must obtain a Conditional Use Permit.
(4) Total area of signs on the exterior front surface of a building shall not exceed twenty
(20) percent of the front surface of the building. The total area of signs on a side or rear surface of a building shall not exceed twenty-five (25) percent of the exterior, side, or rear surface of the building. The combined sign area on the front, side and rear surface of a building shall not exceed six hundred (600) square feet.
(5) Projecting signs shall not extend above the roofline a distance greater than the height of the roof above ground level. In no case shall signs project beyond property lines. The minimum height above grade of sidewalk level of projecting signs shall be no more than ten (10) feet.
Allowable Signs in General Commercial; Highway Commercial; Light Industrial;
Heavy Industrial; Parks, Education, & Health, and Public Works Districts
(GC, HC, LI, HI, PEH, PW)
Type of Sign Number of Signs Allowed Maximum Display Area per Sign Maximum Height Setback from Right-of-Way Permanent Freestanding - 1 per building;
Projecting - 1 per building (1);
Wall - 5 per building (2);
Roof - 1 per building Freestanding - 100 sq. ft. (3);
Projecting - 20 sq.
ft.;
Wall (4) Roof - 50 sq.ft.
Freestanding - 30 ft. (3);
Projecting-(5);
Wall - No higher than top of wall;
Roof - 20 feet above roof Freestanding - 10 ft. (3) Temporary (8) Freestanding - 1 per business;
Portable - 1 per business 25 square feet 6 feet 10 feet
(1) Projecting signs must not project more than six and one-half (61 /2) feet from the wall and
may be located not closer than eighteen (18) inches to the vertical plane at the street curb line.
(2) Wall signs shall not project more than twenty-four (24) inches beyond the wall.
(3) Signs exceeding these limits must obtain a Conditional Use Permit. Freestanding signs that are closer than one hundred (100) feet from another freestanding sign must obtain a Conditional Use Permit.
(4) Total area of signs on the exterior surface of a building shall not exceed twenty (20) percent of the front surface of the building. The total area of signs on a side or rear surface of a building shall not exceed twenty-five (25) percent of the exterior side, or rear surface of the building. The combined sign area on the front, side and rear surface of a building shall not exceed six hundred (600) square feet.
(5) Projecting signs shall not extend above the roofline a distance greater than the height of the roof above ground level. In no case shall signs project beyond property lines. The minimum height above grade of sidewalk level of projecting signs shall be no less than ten (10) feet.
(6) Sign structures shall not be spaced closer than three hundred (300) feet to any other advertising sign on the same side of any street except when back to back or end to end. Sign structures on state and interstate highways shall comply with the Department of Transportation requirements.
(7) Permits for temporary promotional signs may be approved for a maximum of four (4) weeks. A Conditional Use Permit is required for use of such signs for a period of greater than four (4) weeks.
Allowable Signs in the Planned Development District (PD) Type of Sign Number of Signs Allowed Maximum Display Area per Sign Maximum Height Setback from Right-of-Way Permanent Ground - 1 sign at each entrance 20 sq.ft. 6 feet 10 feet (4) Permanent Wall - 1 sign per building 5% of the square footage of the front of the building up to a maximum of 40 sq. ft.
No higher than the top of the wall Permanent Wall - sign per business 15 square feet No higher than the top of the wall
(1) To place a double faced sign in a median at an entrance of a planned Development there will be no set back requirement if the Chief Codes Official determines such sign will not constitute a traffic hazard.
Historia
(Ord. No. 0-04-25, § 9, 9-7-04)
Leer este código donde se publica (Municode) La fuente es el código de la ciudad tal como lo publica su editorial o su propio sitio web. Consúltelo allí para ver cambios posteriores.