A. Concrete pipe jointing. Rubber type gaskets and joints shall conform to the requirements of AASHTO: M 198, Type A, except that for pipe to be used in culvert construction, exfiltration tests will not be required.
B. Cast iron pipe (all types). Rubber type gasket joints for cast iron and ductile cast iron pipe shall conform to the requirements of AWWA: C 111.
1. Plain end pipe. Plain end cast iron pipe may be joined with steel bolted couplings.
Certification: The pipe, gasket or joint, manufacturer shall furnish to the engineer a certification showing physical properties of the rubber gasket and results of hydrostatic tests of the gasket and pipe to be used in the work.
C. Steel sewer and water pipe.
1. Bell and spigot joints for steel water pipe and sewer pipe shall conform to AWWA: C
202. The rubber gasket material shall conform to AWWA: C 301.
2. Plain end steel pipe may be joined with steel bolted couplings.
28.05 Steel bolted couplings. Steel bolted couplings for joining plain end pipe (all types).
A. Couplings. Couplings shall be of the wedge-gasketed, flared sleeve type. Each coupling shall consist of one steel middle ring, two steel followers, two wedge-shaped rubber-compound gaskets and steel bolts. Couplings shall be of the proper dimensions and type applicable to the size and kind of pipe to be joined, including reducers, where required.
Sec. 29 - Precast Concrete Catch Basin, Drop Inlet, and Manhole Units.
29.01 Description. This specification covers the manufacture of precast reinforced concrete catch basins, drop inlets and manhole units. The finished units shall conform to the dimensions shown on the plans.