Appendix C - ROADWAY AND SUBDIVISION SPECIFICATIONS

7.03. Construction.

Sobre este texto

  • As published by Municode, retrieved 2026-11-11
  • The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.

Las notas de arriba, el texto de la sección y su línea de historia se muestran en inglés, tal como los publica la fuente y como los da el corpus.

A. Placing materials. The materials shall be spread uniformly with a mixture spreader to the proper depth to obtain the specified thickness. Graded aggregate materials containing frost or frozen particles shall not be placed.

B. Thickness of course. The maximum thickness to be laid in one course shall be six inches compacted. If the design thickness

of the base, subbase or shoulder course is more than six inches, it shall be constructed in two or more courses of approximately equal thickness. With a sufficient and suitable equipment, the engineer may

allow base material to be placed in lifts up to eight inches.

C. Compacting and finishing.

1. Compaction. The moisture content of the mixture of materials at the time of compaction shall be uniformly distributed and shall be adequate to allow compaction to the specified density. After the material

placed has been shaped to line, grade and cross-section, it shall be rolled until the course has been uniformly compacted to at least 98 percent of the maximum dry density.

The compacted base shall have sufficient stability to support construction equipment without pumping irregardless of compaction. If the base material becomes unstable as a

result of too much moisture, the base material and the underlying subgrade, if necessary, shall be dried and reworked to a moisture content that will provide stability and compaction.

D. Tests. AASHTO: T180 Method D.

[Secs. 8—10. Omitted.]

Sec. 11. Bituminous prime.

Leer este código donde se publica (Municode) La fuente es el código de la ciudad tal como lo publica su editorial o su propio sitio web. Consúltelo allí para ver cambios posteriores.

Versión local-code:cusseta-chattahoochee/zoning/appendix-c-7.03@2026-11-11-4435296427

El asistente puede decir lo que dice esta sección en esta edición, citándola y enlazándola. No aplicará la ley a su situación, y nada de esto es asesoría legal.

Cusseta-Chattahoochee County unified government Zoning Ordinance, 7.03 (Appendix C). Construction | Georgia Commons