(a) All grading operations must be conducted in compliance with an approved site plan.
(b) Before beginning construction activity, the floodplain must be identified throughout the entire development by staking or other identifying mechanisms no less than every 100 feet.
(c) Grading must be performed to avoid the restriction of drainage through drainageways and drainage easements. Grading must be performed to provide positive drainage to storm drainage inlets, swales, channels, ditches or
gutters.
(d) Finish grade slopes on residential projects and lots may not be steeper than 3:1, unless absolutely impractical due to vegetation,
topography, or soil conditions. Three-to-one finish grade slopes must transition to 2:1 slopes at all perpendicular stream crossings.
(e) Large-scale general grading must include installation of approved soil and erosion control measures and be limited to phases approved by the community development director and completed prior to commencing building
construction.
(f) Grading and filling in floodplains is prohibited, except as expressly allowed by article II, division 8.
(g) The burying, piling, or concealing in any way of construction waste is prohibited. No certificate of occupancy may be issued until the applicant provides written certification to the
community development director, accompanied by a landfill receipt, indicating that all construction waste has been removed from the property.
(h) Fills must be placed in uniform layers not to exceed a compacted thickness of six inches per layer. In all areas where structures, parking lots and drives, streets, dams and utilities are to be placed fill must be compacted to a density of at least 95 percent of the maximum laboratory dry weight per cubic foot, as determined by ASTM D 698 All other fills must be compacted to a least 85 percent, except for the upper one foot of roadways, which must be compacted to 98 percent.
(i) Fill dirt, permitted through the issuance of a separate land disturbance permit on any residentially-zoned property shall be limited to:
(1) A cumulative maximum of 1,000 cubic yards per property; and
(2) No more than 20 trips per day, including trips to and from the permitted property.
(3) Separate land disturbance permits issued under this subsection must be used only in accordance with the provisions of
the zoning district on which the property is situated and its intent and not for any commercial purposes.
(Ord. No. 2013-10-14, 1(Exh. A § 16-4.20), 10- 14-2013; Ord. No. 2014-10-16, § 1, 10-27-2014;
Ord. No. 2015-01-04, § 1, 1-26-2015)
Leer este código donde se publica (Municode) La fuente es el código de la ciudad tal como lo publica su editorial o su propio sitio web. Consúltelo allí para ver cambios posteriores.