Dunwoody · Ordenanza de zonificación
Part II - CODE OF ORDINANCES / Chapter 27 - ZONING TABLE OF CONTENTS / Article II - ZONING DISTRICTS / Division 5 - PERIMETER CENTER DISTRICTS
Sec. 27-104. Districts.
Sobre este texto
- As published by Municode, current through 2020-02-10
- The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.
Las notas de arriba, el texto de la sección y su línea de historia se muestran en inglés, tal como los publica la fuente y como los da el corpus.
(a) Districts and regulating map.
(1) District map. The permitted location for each Perimeter Center district is designated in figure 27-104-1, regulating map.
(2) District requirements. The requirements in this subsection apply to the Perimeter Center districts as follows.
a. Requirements specific to each district. Refer to [sections] 27-104(b) through 27-104(e) for specific descriptions and requirements for each district.
b. Use requirements for all districts.
Refer to [section] 27-104(f) uses for use requirements applicable to all districts.
c. Sustainability measures for all districts. Refer to [section] 27-104(g), sustainability measures, for sustainable development practice requirements applicable to all districts.
(3) Street types. Refer to section 27-98(b)(b) street types within the Perimeter Center Overlay for information on street types and street frontage requirements applicable to all Perimeter Center districts.
(4) Transition yards. Refer to section 27- 230, transition yards, for information on buffer and screen requirements between different districts and uses.
(5) New streets and blocks. Refer to section 27-98(c), streets and blocks, within the Perimeter Center Overlay for information on new street design requirements and block configurations.
(6) Other Perimeter Center Overlay requirements. Refer to section 27-98(d), general building design criteria within the Perimeter Center Overlay.
(b) PC-1 district. Requirements for this district are provided in figure 27-104-2, PC-1 district requirements.
(1) Description and intent. The PC-1 district is intended to apply to the central core area of Perimeter Center, including the area directly surrounding the Dunwoody MARTA train station. This
district allows for the highest intensity of buildings, a high level of employment
uses, and active ground story uses and design that support pedestrian mobility.
Figure 27-104-2. PC-1 District Requirements
(c) PC-2 district. Requirements for this district are provided in figure 27-104-3, PC-2 district requirements.
(1) Description and intent. The PC-2 district is meant primarily for employment uses, residential buildings, and limited shopfront retail and services.
Figure 27-104-3
PC-2 DISTRICT REQUIREMENTS REFERENCE
PERMITTED BUILDING TYPES
Shopfront • Permitted on Primary Street frontages only, Refer to Figure 27- 98-2 Street Type Map. 27-105 Building Types General • Townhouse • Detached House • Civic • USE MIX Minimum Mix of Uses No mix required 27-104(f) Uses HEIGHT Minimum 1 story; single story
buildings shall be 18 to 24 feet in height.
27-230 for transition yards; 27-105(a)(9)e.
for perimeter buffer;
27-105(b)(2) for floorfloor heights per Building Type Maximum: less than
100 feet from a lot line adjacent to single family zoning district 3 stories or 35 feet, whichever is less Maximum: between 100 feet and 500 feet from a lot line adjacent to single family zoning district 5 stories or 70 feet, whichever is less Maximum: greater than 500 feet to a lot line adjacent to single family zoning district 14 stories or 180 feet, whichever is less Additional Height: in any location Additional height may be approved as a condition of rezoning or, if already zoned, with a special land use permit.
PC-2 DISTRICT REQUIREMENTS REFERENCE
STREETS & BLOCKS Streets & Block Configurations Required per Figure
Leer este código donde se publica (Municode) La fuente es el código de la ciudad tal como lo publica su editorial o su propio sitio web. Consúltelo allí para ver cambios posteriores.