Sec. 27-105. Building types.
Sobre este texto
- As published by Municode, current through 2020-02-10
- The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.
Las notas de arriba, el texto de la sección y su línea de historia se muestran en inglés, tal como los publica la fuente y como los da el corpus.
(a) Requirements for all building types. The building types detailed in this section outline the required building forms for new construction and renovated structures within the Perimeter Center districts defined in [section] 27-104, districts.
(1) Applicability. The requirements of this section apply to all new development, or new structures or buildings, established in [section] 27-103(a)(2). All structures must meet the requirements of one of the building types permitted within the zoning district.
(2) Districts, building types, and street types.
For each lot, a designated Perimeter Center district is found on figure 27- 104-1, regulating map.
a. District. Each district, per [section] 27-104, districts, has a set of requirements related to streets, open space, uses, and permitted building types.
b. Building types. Each building type, as established in this section 27- 105, has a set of requirements, including requirements related to the façades facing different street types.
c. Street types. Street types, per section 27-98(b), street types, of the Perimeter Center Overlay, include
frontage requirements for the space between the build-to zone of the building type and the curb of the street.
(3) Uses. Uses are permitted by district, per [section] 27-104(f), uses. Each building type can house a variety of uses depending on the district in which it is located.
Some building types have additional limitations on permitted uses as located within the building.
(4) General building design requirements.
Refer to section 27-98(d), general building design criteria within the Perimeter Center Overlay, for information on building design requirements additional to and applicable to all building types.
(5) Multiple principal structures. Multiple structures are permitted on all lots in the perimeter center districts. All structures shall meet the requirements of one of the permitted building types for the district.
(6) Permanent structures. All buildings constructed shall be permanent construction, unless otherwise noted.
(7) Other structures. Utility structures and towers permitted in the district are exempted from the building type standards.
(8) Build to the corner. The corner of the lot is defined as the intersection of the two build-to zones of each street. Refer to figure 27-105-1, corner and build-to zones on different street types.
a. Corners at primary street and parkways. Buildings shall be built up to the corner, occupying the intersection of the two build-to zones of any intersection of two primary streets,
a primary street at any parkway, or two parkways. Courtyards shall not be located in this area.
b. Corners involving secondary streets.
Buildings should be built to the corner, occupying the intersection of the two build-to zones of any intersection involving a secondary street.
Courtyards should not be located in this area.
(9) Treatment of build-to zones, setbacks, and transition yards. Refer to [section] 27-621 terms defined for definition of build-to zones and setbacks.
a. Landscape areas.All build-to zones and setbacks shall only contain courtyards (as permitted by street type frontage), plazas (as permitted by street type frontage), patios (as permitted by street type frontage), sidewalk or trail extensions, buffers, and/or landscape yards, unless otherwise specifically noted.
b. Transition yards. Refer to [section] 27-230 for size and landscape requirements.
c. Surface parking. Surface parking lot yard location is determined by building type and shall only be permitted in setbacks when the setback is labeled as a "building setback". Parking shall be set back from a lot line abutting another property a minimum of five feet. Refer to [section] 27-105(b), regulations specific to building types.
d. Driveways. Driveways may cross perpendicularly through build-to zones and setbacks, when permitted per [section] 27-105(a)(10), driveways, below, or to connect to a
parking lot on an abutting lots.
e. Perimeter buffer. On all PC district lots, a required transition yard of 100 feet is established at the lot line of a PC district and any City of Dunwoody residential zoning district not within the PCID Overlay area. Within the perimeter buffer,
building height is restricted to three stories or 42 feet, whichever is less.
Refer to [section] 27-104, districts.
(10) Driveway access. Location of vehicular driveway access is based on the major or minor parkway, primary street, and secondary street designations in figure 27-98-2, street types, map per the hierarchy as follows. Refer to figure 27- 105-2, driveway locations by street type.
a. Public works director. The public works director shall determine the quantity of driveways, need for closure of existing driveways, width of driveways, and proximity of driveways to other driveways or streets.
b. Alleys/lanes. Access from an adjacent alley or lane is unlimited. Construction of new private or public alleys/lanes through blocks is encouraged. Typically, alleys or lanes cut through a block and provide
vehicular access to multiple garages, parking lots, or service areas. Minimum pavement width for an alley or lane is 16 feet and maximum pavement width is 24 feet.
c. Secondary street access. If no alley exists, one driveway access per 200 linear feet of street frontage or
two total driveway access points, whichever is greater, are permitted from each secondary street per site.
d. Primary street. If no alley or secondary street exists, one driveway access point is permitted off each primary street.
1. Side parking off primary street.
When side parking with the drive located perpendicular to the street centerline, is utilized as permitted by the building type, one driveway access is permitted off the primary street.
This driveway counts towards entrances permitted by [section] 27-105(a)(10)d, above.
The sidewalk paving shall extend across the driveway, signaling priority to the pedestrian.
e. Parkways. If no alley, secondary street, or primary street exists, existing driveways may be utilized off parkways. New driveways off minor
or major parkways are permitted only if no other option exists and a minor exception is granted by the public works director.
f. Shared driveways. Shared driveways are encouraged for all other adjacent developments.
g. Inter-lot drives. When two or more parking lots are located adjacent to each other and each lot contains the same building type, the parking lots shall be connected with a drive perpendicularly crossing the transition yard. Other parking lots should be connected wherever practical.
h. Pedestrian facilities.At-grade, designated pedestrian routes, including sidewalks and crosswalks, shall be supplied connecting each parking area to either the primary sidewalk (and front entrance) or a rear public entrance.
1. Crosswalks shall include pavers or colored concrete pavement across driveways.
2. Vehicular areas, such as driveways, parking drive lanes, loading lanes, bike lanes/facilities, and parking areas, shall not be utilized as designated
pedestrian routes.
3. Pedestrian connections are desirable between all adjacent sites and land uses.
i. Driveway width. Driveways shall be no greater than 22 feet in width at the right-of-way line. Driveways wider than 22 feet shall include landscaped, pedestrian refuge islands with a walk area to reduce the crossing to no more than 22 feet.
j. Loading facilities. Loading facilities for all building types in all perimeter center districts shall be located as follows:
1. Loading facilities shall not face primary streets.
2. Loading facilities shall not be located in any required building setback area.
3. Preferred location for loading facilities is on the interior of the lot, not visible from any streets.
4. Loading facilities visible from a parkway or secondary street shall be screened from the sidewalk by a fence/wall or a combination of fence/wall and landscape screening.
i. Fence/wall. Fences and walls shall be no taller than six feet and shall have a minimum overall opacity of 80 percent. Materials shall meet the requirements of [section] 27-98(d)(3)a, major façade materials, in the Perimeter Center Overlay.
ii. Landscape. Tree canopies shall be used to screen above the six-foot wall or fence.
iii. Shrubs and hedges.
Shrubs and hedges may be utilized to fulfill no more than one third of the screening, as measured along the screen length.
A double row of five-gallon shrubs, with mature height of a minimum six feet, is required.
k. Accessory buildings. The following applies to all accessory buildings or structures in any PC district:
1. Attached accessory structures are considered part of the principal structure and shall meet all requirements of the principal structure.
2. Detached accessory structures shall comply with all building and district requirements unless otherwise modified in the following:
i. Detached accessory structures are not permitted between the face of the building and any street right-of-way line.
ii. Detached accessory structures shall be a maximum of ten feet lower in height than the overall building height or 15 feet in height, whichever is greater.
(b) Regulations specific to building types.
(1) Building type descriptions and intents.
a. Shopfront building. The shopfront building is intended for use as a mixed use building located close to the sidewalk with parking typically in the rear or side of the lot.
The most distinctive element of this building type is the ground floor front façade with large amounts of storefront glass and regularly spaced entrances, typically for retail and service uses.
b. General building. The general building is intended to be built close to the sidewalk, but may also allow for
a landscape yard and drop off drives.
This building can be structured to house offices or residential uses including multi-family, and may have limited amounts of accessory retail and service uses in the ground floor.
Parking is typically provided in structures at the rear of the lot, internally in the rear of the building, but may
also have limited surface parking along the side of the building.
c. Townhouse building. The townhouse building is a building typically comprised of several multistory single-family units, located adjacent to each other, each with
its own entrance to the street.
d. Detached house building. The detached house building is a building surrounded by landscape yard, with
an entrance facing the street, and typically housing single family uses.
Parking is required to be located in the rear, either incorporated into a detached garage or in an attached garaged accessed from the rear of the building.
e. Civic building description. The civic building is the most flexible building type limited to civic and institutional types of uses.
These buildings are distinctive within the urban fabric created by the other building types and could be designed as iconic structures.
(2) Building type regulations. The following defines and illustrates the regulations for each building type.
a. Shopfront building regulations.
b. General building regulations.
c. Townhouse building regulations.
d. Detached house building regulations.
e. Civic building regulations.
(c) Explanation of specific building type requirements. The following explains and further defines the standards outlined on the tables on
the previous pages, specific to each building type, refer to [subsections] (b)(2)a through (b)(2)e.
(1) Building siting by street types. The following explains the line item requirements for each building type table within the section entitled "Building siting."
For each building type, requirements are defined for each street type frontage that may occur surrounding the site. Refer to figure 27-98-2, street types map, for the type defined for each street in the Perimeter Center area. Each street type is defined with frontage options in [section]
27-98(b), street types, including the major and minor parkway, primary street, and the secondary street.
a. Build-to zone coverage. The minimum percentage of building wall or façade along the street for each
street type (parkway, primary street, secondary street per figure 27-98-2, street types map) is designated on each building type table. Refer to [subsections] (b)(2)a through (b)(2)e.
1. Measurement.The width of the principal structures (as measured within the build-to zone along the frontage edge) is divided by the length of the frontage parallel to the property line following the street. Refer to
figure 27-105-18, minimum build-to zone coverage.
2. Courtyards. Courtyards, per [section] 27-621, terms defined, located along the façade in the build-to zone count towards the minimum coverage. Refer to street types for limitations of courtyards along
some frontages.
b. Build-to zone. The build-to zone is designated separately for each street type frontage on each building type table. Refer to figure 27- 105-1, corner and build-to zones,
on different street types and figure 27-98-2, street types map.
1. Measurement. The build-to zone for all districts and street type frontages is measured from the edge of the street type frontage area onto the site, along the frontage edge.
Refer to figure 27-105-19, location of build-to zone in relation to frontage.
2. Encroachments. Awnings and building mounted signage may extend beyond the build-to zone into the frontage area, but may not extend into the street right-of-way.
3. Porches, arcades, galleries.
Porches, arcades and galleries may be included on the building façade design, utilizing the range of depth permitted by the build-to zone. If located outside the building coverage requirement, the
depth of the arcade or gallery may exceed the build-to zone.
c. Off-street parking along frontage.
Off-street parking is permitted behind any buildings on the site, but is only permitted exposed along a
frontage if designated on the table of requirements for each building type.
1. Side parking. Where noted, side off-street parking along a primary street may be permitted with a maximum of one double loaded aisle of parking
perpendicular to the street centerline and with a maximum width of 72 feet. Refer to the street type frontage parking edge for design requirements in front of the parking and figure 27-105-20, side offstreet parking.
(2) Floor-to-floor height. The following explains the line item requirements for each building type table within the section entitled "Floor-to-floor height."
Overall permitted building heights are designated by district in stories. Refer to [section] 27-104 districts.
a. Ground story, minimum and maximum height.(Refer to figure 27-105- 21, measuring story height). Each
building type indicates a permitted range of height in feet for the ground story of the building.
1. Taller spaces. Spaces exceeding the allowable floor-to-floor heights of the building type are
not permitted on primary street façades. These spaces are unlimited on interior lot and secondary street façades, and limited to no more than 50 percent of major or minor parkway façades.
b. Ground story elevation. The allowable ground story elevation for each building type is defined, establishing whether or not a visible basement is permitted.
1. Visible basements. Visible basements, permitted by entrance type, are optional. The visible basement shall be a
maximum of one-half the height of the tallest story.
(3) Uses within building. The following explains the line item requirements for each building type table within the section entitled "Uses within building." Refer to [section] 27-104(f), uses for uses permitted within each zoning district. The requirements in this section of the building type tables may limit those uses within a specific building type.
a. Ground and upper story. The uses or category of uses which may occupy the ground and/or upper story of a building.
b. Parking within building. The area(s) of a building in which parking is permitted within the structure.
c. Required occupied space. The required depth of occupied space from the noted façade(s). Refer to [section] 27-621, terms defined, for the definition of occupied space.
(4) Street façade design requirements. The following explains the line item requirements for each building type within the section entitled "street façade requirements".
These requirements apply only to façades facing public or private streets and façades facing main parking lots
where visitors or customers park.
a. Minimum fenestration. (refer to figure 27-105-23, measuring fenestration, per façade). The following articulates the minimum amount of ground story transparent glass required on façades facing street and parking façades.
1. Measurement. Ground story windows, when defined separately from the overall minimum fenestration, shall be measured between two feet
and eight feet from the average grade at the base of the front façade. Refer to figure
27-105-22, measuring ground story windows.
2. Transparent. Transparent means any glass in windows and/or doors, including any mullions, that is highly transparent with low reflectance.
3. Other stories. A general minimum fenestration requirement applies to all other stories visZONING § 27-105
ible from any street. Refer to [section] 27-98(d)(4),a quantity of windows.
4. Arcades, galleries, courtyards.
Ground story windows shall be located on the interior façade of any arcade or gallery.
Ground story windows shall continue around a minimum of 60 percent of courtyard façades.
b. Entry area. Size requirements and recommended types of entrance areas per building type.
c. Required number of street entrances. The minimum number of and maximum spacing between entrances on the ground floor building façade with primary street frontage.
d. Vertical façade divisions. The use of a vertically oriented expression line or form to divide the façade into vertical divisions at increments no greater than the dimension shown, as measured along the base of the façade. Elements may include a column, pilaster, or other continuous vertical ornamentation a minimum of 1.5 inch depth. Refer to [section] 27-621, terms defined, for
the definition of expression line.
e. Horizontal façade divisions.The use of a horizontally oriented expression line or form to divide portions of the façade into horizontal divisions at locations designated. Elements may include a cornice, belt course, molding, string courses, or
other continuous horizontal ornamentation a minimum of 1.5 inch depth.
(Ord. No. 2017-05-14, § 2(Exh. B), 5-22-2017;
Ord. No. 2019-01-03, § II, 1-28-2019)