The following building separation requirements apply to all multi-unit buildings on sites containing two or more multi-unit buildings. For
the purpose of these provisions, the front and rear faces are those exterior building walls generally perpendicular to the party walls between dwelling units and the side face is the exterior
building wall that is generally perpendicular to the building's front and rear faces.
(1) Building setbacks must be provided as required by the applicable zoning district requirements.
(2) Buildings that are front face to front face, rear face to rear face, or front face to rear face must be separated by a distance of at least 60 feet.
(3) Buildings that are side face to front face or rear face must be separated by a distance of at least 40 feet.
(4) Buildings that are side face to side face must be separated by a distance of at least 20 feet.
(5) Buildings may not exceed 250 feet in length along any elevation.
Historia
(Ord. No. 2013-10-15, § 1(Exh. A § 27-9.120), 10-14-2013)
Leer este código donde se publica (Municode) La fuente es el código de la ciudad tal como lo publica su editorial o su propio sitio web. Consúltelo allí para ver cambios posteriores.