(a) Measurement.

(1) Detached houses. The building height of a detached house is measured as the vertical distance from the front door threshold elevation to the highest point of the roof ([see] Figure 30-2).

(2) Other buildings. For all buildings except detached houses, building height is measured as the vertical distance from finished grade along the exterior building wall to the top of the highest roof beams or top of parapet (whichever is greater) on a flat or shed roof, the deck level on a mansard roof, and the average distance between the eaves and the ridge level for gable, hip, and gambrel roofs ([see] Figure 30-3).

Figure 30-2: Building Height Measurement, Detached Houses

(b) Exceptions.

(1) Farm buildings and farm-related structures are not subject to building height limits when located on bona fide farms.

(2) Belfries, clock towers, cupolas, domes, flag poles and spires may exceed maximum building limits, provided they are not intended for human occupancy.

(3) Bulkheads, elevator and equipment penthouses, chimneys, water tanks and similar structures may exceed maximum height limits, provided they do not cover

more than 25 percent of the total roof area of the building on which they are located.

(4) Telecommunications towers and antennas are subject to their own special height limits (see section 27-150).

(5) Building-mounted solar energy systems may extend up to three feet above the applicable maximum zoning district height limit, provided they do not extend more than five feet above the roof line (see also subsection 27-173(b)).

Historia

La línea de historia que la fuente imprime al final de la sección.

(Ord. No. 2013-10-15, § 1(Exh. A § 27-30.70), 10-14-2013; Ord. No. 2015-01-05, § 1, 1-26- 2015)

Leer este código donde se publica (Municode) La fuente es el código de la ciudad tal como lo publica su editorial o su propio sitio web. Consúltelo allí para ver cambios posteriores.

Versión local-code:dunwoody/zoning/27-577@2020-02-10-56e367a61b

El asistente puede decir lo que dice esta sección en esta edición, citándola y enlazándola. No aplicará la ley a su situación, y nada de esto es asesoría legal.

Dunwoody Zoning Ordinance, Sec. 27-577. Building height | Georgia Commons