Dunwoody · Ordenanza de zonificación
Part II - CODE OF ORDINANCES / Chapter 27 - ZONING TABLE OF CONTENTS / Article II - ZONING DISTRICTS / Division 4 - OVERLAY ZONING DISTRICTS
Sec. 27-98. Perimeter Center Overlay.
Sobre este texto
- As published by Municode, current through 2020-02-10
- The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.
Las notas de arriba, el texto de la sección y su línea de historia se muestran en inglés, tal como los publica la fuente y como los da el corpus.
(a) Overlay generally.
(1) Intent. The regulations of the Perimeter Center Overlay are intended to recognize and foster the transformation of Perimeter Center into a pedestrian-friendly, livable center that ensures long term
economic, social, and environmental sustainability.
(2) Purpose. The Perimeter Center Overlay has been created to further the following public purposes.
a. Plan compatibility. To guide new development and redevelopment as defined by the City of Dunwoody
Comprehensive Plan (adopted 2015) and as amended.
b. Perimeter Community Improvement districts (PCIDs). To provide implementation guidance for the general vision defined in Perimeter @ The
Center - Future Focus, 2011 - A Ten Year LCI Update, dated November 2011, as amended (past, current, and future), and adopted by city council.
(3) Applicability. The regulations within this section, 27-98 Perimeter Center Overlay, apply to all buildings, structures, land and uses within the Perimeter Center
Overlay, as illustrated on the city's zoning map and in figure 27-98-1, Perimeter Center Overlay map.
(4) Existing land development regulations.
Refer to chapter 16, land development regulations, for additional requirements.
When there is a conflict between the following regulations and chapter 16, the Perimeter Center Overlay regulations govern.
(5) Review and approval procedures. Unless otherwise expressly stated, all uses and development in Perimeter Center
Overlay are subject to the applicable review and approval procedures of article V, as well as any applicable procedures in chapter 16 of the Municipal Code (land development regulations).
(6) Site plan review. All applications for development permits within the Perimeter Center Overlay must be accompanied
by a site plan, which is subject to review and approval in accordance with article V, division 10.
(7) Relief. In some instances, unique site conditions, existing building circum- stances or other constraints related to the subject property may make strict compliance with the Perimeter Center Overlay regulations impossible or highly impractical. In such instances, an applicant may seek relief from applicable regulations. Any relief granted and conditions imposed run with the land and are binding on the subject property owner and all future property owners.
a. Minor exception—Administrative relief. The community development director or public works director, as
noted, is authorized to approve the following minor exceptions to strict compliance in accordance with the special administrative permit procedures of article V, division 7:
1. A change to any street or frontage option component width or depth (requires approval by
the public works director);
2. A reduction in required landscape or yard depth by no more than ten percent;
3. Establishment of a public access easement in lieu of rightof-way dedication for street type frontage options, per the
public works director.
4. Retaining walls in street type frontages up to five feet in height when extreme grades prevent the use of shorter walls and landscaping is used to mitigate the visual impacts of the taller retaining wall at the sidewalk edge; and
5. Any other minor exception expressly authorized under the Perimeter Center Overlay regulations.
b. Major exceptions—Variance. Major exceptions to strict compliance with the Perimeter Center Overlay
regulations include any exception to strict compliance that is not expressly authorized as a minor exception under the provisions of subsection (a)(7)a. Major exceptions require review and approval in accordance with the variance procedures of article V, division 5.
(b) Street types.
(1) Intent. Street types are established for all of the existing and new streets in the Perimeter Center Overlay area. Frontage options are defined for the space between the building or parking and the
curb per street type. Street types and frontage options are intended to address the comfort, convenience, and safety of pedestrians and bicyclists; to
develop a network of streets with identifiable character; and to provide an aesthetically pleasing edge to all development.
(2) Applicability. All new development and redevelopment within the Perimeter Center Overlay shall meet the street type frontage requirements under any one of
the following circumstances:
a. New structure. Development of a new principal structure on a lot or a portion of a lot.
b. Redevelopment or renovation. Redevelopment or renovation of an existing structure or site that increases the gross building square footage by more than 50 percent.
c. Parking lots. Redevelopment or revision to 50 percent or more of an existing parking lot or development
of a new parking lot consisting of 15 or more spaces, not including resurfacing or repairing an existing layout.
(3) Street types map. Figure 27-98-2, street types map, defines street types in Perimeter Center for existing and new streets.
Refer to [subsection] (c), streets and blocks, for more information about new streets and their designated locations.
Locations illustrated on the street types map are approximate. The requirements and locations of all streets shall be determined by and approved by the public works director during the site plan review process.
a. Street types. The following street types are established for the existing streets and any new streets adjacent to and within the Perimeter Center Overlay. Refer to figure 27-
98-2, street types map, for the typologies of existing streets and proposed new streets.
1. Major parkway street. The major parkway street type is intended to create a parkway effect along the major transportation corridors within Perimeter Center through the use of wide landscape areas
heavily planted with native or naturalized trees. Major parkways require designated bicycle facilities. Refer to [subsection] (b)(5), major parkway street type, for requirements.
2. Minor parkway street. The minor parkway street type is intended to create a parkway effect along transportation corridors within Perimeter Center through the use of wide landscape areas heavily
planted with trees. Minor parkways require designated bicycle facilities. Refer to [subsection] (b)(6), minor parkway
street type, for requirements.
3. Primary street. The primary street type is intended to establish a series of comZONING § 27-98 fortably scaled streets with continuous
building frontage and a limited number of drives interrupting the sidewalk. Primary streets require a balance between bicyclists and pedestrians and automobiles by providing designated bicycle facilities and a robust pedestrian realm, and by prioritizing bicyclists and pedestrians for a more balanced transportation route. Refer to [subsection] (b)(7), primary street type, for requirements.
4. Secondary street. The secondary street type is meant to establish a designated street for parking lot and structure access, while still providing a safe and comfortable pedestrian realm. Refer to
[subsection] (b)(8), secondary street type, for requirements.
b. Street type graphics. The graphics provided in this section illustrate the preferred configuration of each street type. By applying the standards defined, other configurations are permitted.
c. Redesignating street types. Existing street designations are set to match the existing character to the
extent possible. New streets have been designated with the intent to provide an appropriate mix of primary and secondary streets, establishing comfortable pedestrian streets while providing for parking
access. Redesignation of existing streets may occur per the following:
1. Process. Parkways shall not be re-designated, except by a text amendment to this code.
All other streets may be redesignated using the minor exception process.
2. Entire blocks. When redesignating street types, the entire street between intersecting
streets shall be redesignated.
3. Primary streets. The intent is to maintain a similar amount of primary streets as established by the map. Primary streets may be re-designated as parkways or secondary streets only when a new or existing street, currently designated as secondary, within or abutting the same parcel is
redesignated as a primary street.
4. Secondary streets. Existing secondary streets may be redesignated as parkways or primary streets as long as vehicular access to parking for all surrounding sites has been addressed.
d. Shared-use paths. Trail locations are required per the city's current comprehensive plan or other cityapproved cycle/pedestrian plan and in coordination with public works
director for locations for other trails.
(4) Streetscape furnishings and hardscape design. In addition to the street type frontage requirements that include minimum tree plantings and walk/trails, a street furnishings and hardscape design
is required along all new and existing street frontages per the following:
a. Definition. The streetscape furnishings and hardscape design shall include the frontage area as defined by the street types plus any hardscaped building setback area
less than 25 feet deep from the frontage edge.
b. Design submittal. A consistent design shall be submitted for approval with site plan review for all streets
within and adjacent to the development.
c. Standard specifications. The design shall meet any standards defined by the city for sidewalk, curb, access, lighting, landscape, and
other applicable construction details. Refer to chapter 16, land development regulations.
d. Perimeter Community Improvements districts (PCID) public space standards. Refer to the current PCID
public space standards document for recommended streetscape component and material specifications.
e. Submittal requirements. At a minimum, the design submittal shall include the following:
1. Trees. Trees meeting the minimum requirements of [subsection] (b), street types, shall be included in the design, with
details related to tree pits, tree grates, and tree planting to meet the landscape installation requirements of [section] 27-364, landscape.
2. Pavement design. Paving materials and pattern is required for each sidewalk and any
other hardscape proposed.
Pavement design shall address all walks or trails, including the minimum sidewalk or trail widths required by the
frontage.
3. Street furnishings. Benches and/or seatwalls, planters, planter fences, tree grates, and trash receptacles shall be specified and quantities and locations listed for each street.
For each block face, a minimum of two benches or seatwalls, one trash receptacle, and one recycling receptacle are required.
4. Bus stop facilities. Coordinate with the public works director for the location of bus stops and the required facilities. Facilities may include benches, pavement, shelters, signs, and
other improvements.
5. Landscape design. Ground plane vegetation shall be designated for any landscape bed areas, planter areas, and open
tree wells, including shrubs, perennials, annuals, and grasses.
6. Lighting. Pedestrian and vehicular lighting shall be specified with locations and quantities noted. All lighting shall meet any requirements of the
public works director. Cut sheets and samples shall be submitted upon request.
7. Stormwater facilities. Any stormwater facilities proposed for the right-of-way shall be included in the streetscape design. Facilities such as stormwater planters or parkway swales may be included.
Maintenance responsibilities and processes shall be included.
8. Identity elements. Any other elements designed to establish the identity of each street, such as banners mounted on
light poles, pavement markers, artwork, or wayfinding signage, shall be included in the design submittal.
9. Streetscape maintenance.
Property owner is responsible for regular maintenance and emptying of trash and recycling receptacles, sweeping of sidewalks and seating areas,
and tree maintenance. The city may request additional maintenance procedures.
10. Streetscape design continuation.The approved streetscape design for each street may be
utilized by the city for the extension of any street outside the development to provide
continuity.
(5) Major parkway street type. The major parkway street type applies to existing streets per figure 27-98-2, street types map. Refer to figure 27-98-3, table of major parkway street type requirements and figure 27-98-4, existing major parkway street section.
a. New major parkway streets. New major parkway streets are not permitted, unless otherwise required by the public works director. This
street type is applicable only to existing streets per figure 27-98-2, street types map.
b. Frontage options. Frontages address the pedestrian and bicycle realm as well as street and parking
buffers and public space options.
Parcels that are adjacent to a major parkway as designated on the figure 27-98-2, street types map, shall apply one or more of the major
parkway street frontage options along the entire length of the lot line abutting the major parkway. Refer to figure 27-98-5, table of major parkway street type frontage options.
c. Dedication. When the sidewalk is fully or partially located on private property, right-of-way dedication is required, so that the sidewalk is fully located in the right-of-way. The public works director may approve an easement in lieu of right-of-way dedication based on the geometry of the site, topography, or other sitespecific considerations.
d. Curb movement. The existing street curb may be required to move, based on the selection of the appropriate context-sensitive bicycle facility, per public works director.
(6) Minor parkway street type. The minor parkway street type applies to existing streets per figure 27-98-2 street types map and is available for new streets per public works director. Refer to figure 27- 98-9. Table of minor parkway street type requirements and figure 27-98-10 minor parkway street section - existing and new.
a. New minor parkway streets. New minor parkway streets are not permitted, unless a minor exception is approved by the public works director.
b. Frontage options. Frontages address the pedestrian and bicycle realm as well as street and parking
buffers and public space options.
Parcels that are adjacent to a minor parkway as designated on figure 27-98-2, street types map, shall apply one or more of the minor parkway street frontage options along the entire length of the lot line abutting the minor parkway. Refer to figure 27-98-11, table of minor parkway street type frontage options.
c. Dedication. When the sidewalk is fully or partially located on private property, right-of-way dedication is required, so that the sidewalk is fully located in the right-of-way. The public works director may approve an easement in lieu of right-of-way dedication based on the geometry of the site, topography, or other sitespecific considerations.
d. Curb movement. The existing street curb may be required to move, based on the selection of the appropriate, context sensitive bicycle facility, per the public works director.
(7) Primary street type. The primary street type applies to new and existing streets per figure 27-98-2, street types map.
a. New primary streets. Refer to figure 27-98-15, table of primary street type requirements, for primary street
type requirements for new streets, figure 27-98-16, primary street type section: typical, illustrates the typical street section. A narrow version is available for limited application
(refer to figure 27-98-17, primary street type section: narrow).
b. Frontage options. Frontages address the pedestrian and bicycle realm as well as street and parking
buffers and public space options.
Parcels that are adjacent to a primary street as designated on figure 27-98-2, street types map shall apply one or more of the primary street frontage options along the entire
length of the lot line abutting the minor parkway. Refer to figure 27- 98-18, table of primary street frontage options.
c. Dedication. When the sidewalk is fully or partially located on private property, right-of-way dedication is required, so that the sidewalk is fully located in the right-of-way. The public works director may approve an easement in lieu of right-of-way dedication based on the geometry of the site, topography, or other sitespecific considerations.
d. Curb movement. The existing street curb may be required to move, based on the selection of the appropriate, context sensitive bicycle facility, per the public works director.
(8) Secondary street type. The secondary street type applies to new and existing streets per figure 27-98-2, street types map.
a. New secondary streets. Refer to figure 27-98-25, table of secondary street type requirements for secondary street type, requirements for new streets, figure 27-98-26, secondary street type section - typical, illustrates the typical street section.
A narrow version is available for limited application (refer to figure 27-98-27, secondary street type section - narrow).
b. Frontage options. Frontages address the pedestrian and bicycle realm as well as street and parking
buffers and public space options.
Parcels that are adjacent to a secondary street as designated on figure 27-98-2, street types map, shall apply one or more of the secondary
street frontage options along the entire length of the lot line abutting the secondary street. Refer to figure 27-98-28, table of secondary street frontage options.
c. Dedication. When the sidewalk is fully or partially located on private property, right-of-way dedication is required, so that the sidewalk is fully located in the right-of-way. The public works director may approve an easement in lieu of right-of-way dedication based on the geometry of the site, topography, or other sitespecific considerations.
d. Curb movement. The existing street curb may be required to move, based on the selection of the appropriate, context sensitive bicycle facility, per the public works director.
(c) Streets and blocks.
(1) Intent. The intent of the following requirements is to form an interconnected network of streets with multiple intersections and block sizes scaled to support multiple modes of transportation, including walking, biking, transit use, and driving, within the Perimeter Center Overlay area. Also refer to chapter 16 for additional regulations.
(2) Applicability. All new development and redevelopment on site five acres or larger within the Perimeter Center Overlay shall meet the general block, lot, and street design requirements under any of the following circumstances:
a. New structure. Development of a new principal structure on a lot or portion of a lot.
b. Redevelopment or renovation. Redevelopment or renovation to an existing structure or site that increases the gross building square footage by more than 50 percent.
c. Parking lots. Redevelopment or revision to 50 percent or more of an existing parking lot or development
of a new parking lot consisting of 15 or more spaces, not including resurfacing or repairing an existing layout.
(3) New street locations.
a. Street types map. Proposed street locations are illustrated on figure 27-98-2, street types map, defined to establish a network that would fulfill the streets and blocks intent and regulations.
b. Public works director. Locations illustrated on the street types map are approximate. The requirements
and locations of all streets shall be determined by and approved by the public works director during the site plan review process.
(4) Street connectivity. The following provides requirements and guidance for locating new streets and connecting to surrounding context.
a. The arrangement of streets shall provide for the continuation of existing streets from adjoining areas into new developments.
b. Cul-de-sac and dead end streets should be avoided and utilized only when topography and other existing barriers, such as highways, rail lines, or waterways, prevent street
connectivity.
c. Streets should follow natural features rather than interrupting or dead-ending at the feature.
d. Streets should terminate at another street with either open space or a building façade across from the termination.
e. When adjacent developments do not provide connectivity, coordinate with the community development director and public works director to determine the potential for future connections and provide for
those connections.
(5) Block configuration. Refer to figure 27- 98-31 for an illustration of typical block elements and section 16-240 for blocks.
a. Blocks should be deep enough to accommodate buildings facing streets with parking located in the interior. Refer to [subsection](b), street types, for minimum building frontages required for all streets.
b. Blocks may be configured to include existing lots within an existing zoning district that is outside of the Perimeter Center Overlay.
c. A network of streets is required to meet the maximum block size requirement. Proposed new streets to meet these sizes are illustrated
on figure 27-98-2, street types map.
d. Block sizes for zoning districts.Block sizes for residential and commercial development and redevelopment are designated in section 16- 240.
e. Block sizes for Perimeter Center (PC) districts. Maximum block perimeter for all PC districts is 2,400 feet. Recommended block perimeter is a maximum of 1,800 feet.
f. Exceptions. Exceptions to block sizes include locations adjacent to natural features, such as steep grades and drainage areas, and other existing barriers, such as an inability to connect to adjacent parcels.
(6) Block driveway access configurations.
a. Blocks may include alleys, drives, or driveway entrances for service, parking accessibility, and other routes internal to the development.
b. Access to blocks should be aligned across the street from access to other blocks.
c. In the Perimeter Center districts, driveway locations are defined in the general building type requirements. Refer to [section] 27- 105(a)(10), driveways.
d. Mid-block pedestrianways. Midblock pedestrianways are required through blocks longer than 800 feet
and at locations that connect public rights-of-way with other public facilities such as parks and transit.
1. When combined with mid-block street crossings, these pathways should align to facilitate easy pedestrian movements.
2. Mid-block pedestrianways should be located in the middle third of a block face.
3. Minimum width for mid-block pedestrianways rights-of-way or easements is 20 feet.
4. A minimum of one canopy tree per 600 square feet of area is required.
5. Mid-block pedestrianways should be treated with the minimum design requirements per [subsection] (b)(4), streetscape
furnishings and hardscape design.
6. Shared-use paths through blocks per [subsection] (b)(3)d, may fulfill the requirements for mid-block pedestrianways.
(7) Street types. Refer to [subsection] (b), street types, for requirements for streets.
a. Street type. All new and existing streets shall utilize one of the permitted street types per figure 27- 98-2 and the requirements of [subsection] (b), street types.
b. Frontage options. For each side of a street adjacent to or within the development, one of the frontage options defined by street type shall be utilized.
c. Other internal street. Other street types completely internal to the development may be approved by the public works director and the community development director through minor exception.
d. Public use.All streets shall be available for public use at all times. Gated streets and streets posted as private are not permitted.
e. Dimensions. The dimensions defined in each street type provide the acceptable ranges. The public works
director shall determine the appropriate configuration and dimensions for each street. Minor exceptions
may be approved by the public works director during the approval process.
f. Additional director requirements.
During the pre-submittal conference, the community development director and/or public works director may adjust requirements for right-of-way, pavement width, or
street elements depending on unique site locations and characteristics.
g. Street construction. All street construction, whether publicly dedicated or privately held, shall follow street type and frontage requirements and any other specifications defined by the city.
h. Private streets. Private streets that prevent street connectivity or are inconsistent with adopted plans shall not be permitted.
(d) General building design criteria.
(1) Intent. These criteria are intended to address each building's appearance and cohesiveness within the overall Perimeter Center Overlay area. Further, the criteria are intended to elicit high quality
buildings, enhance the pedestrian experience, maintain an appropriate scale, and implement the vision for the area as
defined in current plans.
(2) Applicability. The following outlines the general design criteria applicable to all buildings within the Perimeter Center Overlay.
a. Applicable façades. These criteria apply to all façades visible from the street, facing streets, facing main parking lots, and adjacent to open spaces, unless otherwise noted.
b. Applicable development sites. All new development and redevelopment within the Perimeter Center Overlay shall meet the general building design requirements under any of the following circumstances:
1. New structures and additions.
Development of a new principal structure or additions to a principal structure on a lot or a
portion of a lot.
2. Existing façade renovation.An alteration to an existing structure that includes renovation of more than 50 percent of an
applicable façade.
(3) Materials.
a. Major façade materials. Major façade materials include high quality, durable, finish materials, such as
brick, stone, and glass. Other high quality materials may be approved by the director of community development during the site plan process. A minimum of 80 percent of each façade shall be constructed of
major materials. Street façade materials shall continue around the corner of the building to non-streetfacing façades a minimum depth of 20 feet. Refer to figure 27-98-32,
major materials.
b. Minor materials. Acceptable high quality minor façade materials include all major materials; cementbased stucco; wood lap siding and shingles;, architectural metal siding; architecturally finished concrete; fiber cement siding or shingles (such as Hardie Company products or similar); synthetic stucco/EIFS (see restrictions below);
glass block; split-faced, burnished, glazed, or honed concrete masonry units (CMU), cast stone concrete elements. No more than 20 percent of each façade shall consist of minor materials.
c. Accent materials. The following materials may be used for trim, details, soffits, eaves, and other accent areas: vinyl; aluminum and other durable metals; and metal for beams, lintels, trim, and ornamentation.
Other materials may be approved by the director of community development during the site plan process.
d. Restrictions.
1. The use of plain CMU block and vinyl are prohibited as a façade material.
2. Synthetic stucco (EIFS) used on the first or second floor of a building shall be a "high-impact" system. Conventional EIFS may be used above the
second floor.
e. Roof materials. Wherever asphalt shingles are used, they shall be a minimum three-dimensional architectural type.
(4) Windows, awnings, and shutters.
a. Quantity of windows. Window coverage is required for street facing façades and façades visible from
the street that are fully or partially set back no more than 50 feet from the street.
Use Minimum Ground Story Quantity Minimum Upper Story Quantity Residential 20% 15% Eating and drinking establishments, food and beverage retail sales, and retail sales 50% 15% All other uses 35% 15%
1. Measurement and Placement.
Window requirements are measured as a percentage of the façade, or only the portion of the façade within 50 feet of a street, per floor. Windows shall be placed within the area they are measured.
2. Blank walls. Windows shall be distributed so that no rectangular area greater than 30 percent of any story's façade, as measured from floor to floor,
and no horizontal segment of a story's façade greater than 30 feet in width is windowless and violates the minimum percentage requirements.
3. Visibility. One hundred percent of the required streetfacing, street-level window pane surface area must allow
viewing into the ground story for a minimum of eight feet in depth. Unless permitted by the sign ordinance, windows cannot be made opaque by nonoperable window treatments.
Acceptable operable window treatments include curtains, blinds, and shades.
b. Transparent glass.All window glass shall be highly transparent with low reflectance. Light transmission should be approximately 60 percent for ground story windows and a minimum of 55 percent for upper
story windows.
c. Awnings. All awnings shall be canvas or metal. Plastic awnings are prohibited. Awnings shall not be
translucent. Refer to figure 27-98- 33, awnings.
d. Shutters. If installed, shutters, whether functional or not, may be designed to the following standards:
1. All shutters should be sized for the windows, so that if the shutters were to be closed, they would not be too small for complete coverage of the window.
2. Shutters should be wood, metal, or fiber cement. Other "engineered" woods may be approved during the site plan process with an approved samZONING § 27-98 ple and examples of successful, high quality local installations.
(5) Garage doors. The following requirements apply to garage doors provided on any street façade:
a. Location. Garage doors are not permitted on primary street façades unless not utilized for vehicular access (but for patio access, open air dining). Garage doors are permitted on secondary street façades with direct access to the street. The
preferred location is on interior lot façades.
b. Recessed from façades. Garage doors located on street facing façades shall be recessed a minimum of three feet from the dominant façade of the principal building facing the same street.
c. Design. Garage doors facing a secondary street and intended to be closed during business hours shall
be clad with materials consistent with the design of the building. Carriage-style doors are required on the townhouse and detached house
building type.
(6) Ground story at sloping façades.
a. Intent. Given the slopes in many parts of the Perimeter Center area, building design must accommodate grade changes along the sidewalk without creating tall, out-ofscale blank walls. Large, unarticulated building façades signal to pedestrians that an area is not intended for walking, reducing
activity in the area and creating dead zones. Refer to figure 27-98-34, examples of ground story along slope.
b. Regulations for shopfronts.
1. Grade transitions on the building along the sidewalk should be designed to maximize active pedestrian-scale frontages between waist and eye level
while minimizing blank walls.
2. Unless impracticable, the interior floor level should step to match the exterior grade.
3. If it is necessary for the interior floor to remain constant along the grade, changes may be accommodated by a storefront window display space.
4. Knee wall and retaining walls shall not exceed 30 inches in height except along a maximum 15-foot section of façade length.
5. If grade change is more than 12 feet along a single block face, entrance requirements may be increased to one entrance per 80 feet of building frontage.
6. Building entrances adjacent to the street should be within three feet of the elevation of the adjacent sidewalk, unless utilizing the PC district building types.
c. Regulations for residential and other building frontages.
1. Grade transitions at the building along the sidewalk should be designed to minimize blank
walls.
2. Unless impracticable, the interior floor level should step to match the exterior grade.
3. Multiple front entrances along the street activate each segment of building section at each grade.
4. Transition zones between the sidewalk and building façade of porches, terraces, and landscape areas may be used assist with grade changes.
5. If it is necessary for the interior floor to remain constant along the grade, changes can be accommodated by terraced planters and retaining walls.
6. Retaining walls shall not exceed 30 inches in height except along a maximum 15-foot section of frontage.
7. When the elevation of the first floor is more than three feet above grade, windows should be provided into the basement or lower floor elevations.
(7) Fueling stations. Refer to figure 27-98- 35, recommended gas station layout, for one illustration of the following criteria:
a. Building location. A principal building should be built up to any corner with the longest façade along any
primary street. If no primary street abuts the parcel, along the parkway façade.
b. Side yard parking. One double loaded aisle of parking is permitted on the interior side along a primary street, perpendicular to the street.
c. Pumps and canopy location. The pumps and canopy may be located on the interior of the parcel, but may have driveways to a street.
d. Building build-to zone. A building should be built to within five feet to 15 feet of the edge of the street type frontage.
e. Building façade design. The façade of all buildings shall meet all general design criteria within this section, [subsection] (d), general building design criteria.
f. Canopy design. The canopy, columns, and structure shall be constructed substantially of the same materials utilized on the building.
g. Pavement. Site paving shall consist of maximum 22-foot driveways and lanes along parking and along
pumps.All other areas shall be landscaped.
h. Frontage. A maximum of 50 percent of the frontage may be used for parking and fuel areas.
(8) Accessory drive-through structures. Refer to figure 27-98-36, recommended drive-through facility layout, for one illustration of the following requirements:
a. Structure/canopy. Drive-through structures or canopies shall be located on the rear or side façade of the building or in the rear of the lot
behind the building, where permitted by use. The structure should not be visible from any primary
street.
b. Stacking lanes. Stacking lanes shall be located perpendicular to the primary street or behind the building.
c. Canopy design. The canopy, columns, and structure shall be constructed substantially of the same materials utilized on the building.
(9) Parking structures fronting a street. The following requirements are provided for parking structures fronting a secondary street or parkway.
a. Primary streets. Parking structures, whether accessory or principal use, shall not front a primary street, unless otherwise approved with special land use permit per article V, division 3.
b. Perimeter Center districts. In the Perimeter Center (PC) districts, parking structures as the principal use on the lot require a special land use permit (refer to article V, division 3, special land use permits).
c. Parking structure design requirements.
1. Blank wall limitations. On any street façade, no rectangular area greater than 30 percent of any story's façade, as measured from floor to floor, and no horizontal segment of a story's façade greater than 15 feet in width may be solid, blank
wall.
2. Pedestrian entry.A defined pedestrian entrance/exit is required separate from the vehicular entrance and directly accessing the sidewalk. If the
entry is enclosed, windows are required to meet a transparency rate of 65 percent.
3. Structures along highways.
Structured parking located along highways shall incorporate architectural elements (e.g., trellises, planters, landscape, panels) that provide visual screening of vehicles and interior lighting.
(10) Pedestrian entrances.A street-facing pedestrian entrance is required for each ground floor, commercial tenant suite.
The entrance must be open during the respective business' hours of operation.
A pedestrian entrance is defined as a main point of access for pedestrians into a building or suite within a building.
(Ord. No. 2017-05-14, § 1(Exh. A), 5-22-2017;
Ord. No. 2022-06-12, § I, 6-13-2022)
Leer este código donde se publica (Municode) La fuente es el código de la ciudad tal como lo publica su editorial o su propio sitio web. Consúltelo allí para ver cambios posteriores.