A. Brightness limits. The brightness of an illuminated sign shall not exceed 30 foot-candles at any one point on the sign face.

B. Shielding of illumination source. Any light from an illuminated sign, or flood or spot light used to illuminate the sign, shall be stationary, shielded, and directed so that the light intensity or brightness shall:

1. Illuminate only the surface area of the sign;

2. Not interfere with the safe vision of motorists or bicyclists;

3. For spot-lit signs, the sign base and/or proposed landscaping shall be designed to conceal the base of the light fixture to the extent feasible.

C. The use of colored lamps for external lighting of signage is not permitted;

D. No sign that has exposed neon tubes or other exposed tubes containing luminescent gas shall be used outside a building.

E. Fluctuations in lighting. No sign shall have blinking, flashing, scrolling, fading, or fluctuating lights or other illuminating devices that have a changing light intensity, brightness or color or form. No revolving or rotating beam or beacon of light, including but not limited to searchlights, shall be utilized and or permitted as part of any sign.

F. Electrical wiring and equipment. Signs with internal electrical wiring or lighting equipment, and all external lighting equipment shall be inspected and approved by the city in accordance with existing and prevailing electrical codes. All wiring to electrical signs or to lighting equipment directed to ground signs shall be underground.

G. Automatic dimming. New technology signs shall not operate at brightness levels of more than 0.30 footcandles above ambient light levels as measured from a distance of 200 feet. Each sign must have a light sensing device that will adjust the brightness of the display as the natural ambient light conditions change. The owner of the signs shall provide certification of the dimming technology at the time of installation and at yearly intervals thereafter. Additionally, the owner of the sign shall provide to the zoning administrator a 24-hour contact able to turn off the electronic sign promptly if a malfunction occurs until such time as repairs are completed and the brightness recertified.

Historia

La línea de historia que la fuente imprime al final de la sección.

(Ord. No. 2022-011, § 1, 10-24-2022)