(a) General. The subdivider shall provide public improvements as required by all applicable county regulations, specifications, and requirements.

(b) Curbs and gutter. The subdivider shall install curb and gutter and proper drainage as required by county specifications.

(c) Monuments. The subdivider shall provide and set iron monuments at all property corners. The monuments shall be an iron rod or pipe of not less than one-half inch in diameter and not less than 18 inches long and driven to a minimum depth of 12 inches.

(d) Water supply and sanitary sewerage. Every lot within a proposed subdivision shall have an approved supply of adequate water and an approved sewage disposal system, as determined by the county water system and the environmental health county manager.

(e) Public water facilities. Where public water facilities are available within the distance specified below, the subdivider shall assure that every lot of the subdivision shall be provided with public water.

Number of Lots Minimum Distance from Water Line* 6 or more 2,500 feet For each additional lot after six, an additional 150 feet shall be added per lot to the minimum distance from a water line requiring connection thereto.

*Measured along public right-of-way to closest point on property.

Cost differentials based on line sizes and fire hydrants needed to serve a subdivision versus that needed as part of the overall system will be determined by the water system.

(f) Fire hydrants. Standard fire hydrants will be provided at the spacing specified by chapter 12, Fire Prevention and Protection. Design standards shall be as specified by the American Water Works Association.

(g) Sanitary sewer. When a public sewage disposal system is not available, the county environmental health department shall review the preliminary and final plat (major or minor) to determine the feasibility for individual on-site sewage disposal systems. After approval of the final plat (major or minor), on-site sewage disposal system permit applications must be submitted to the county environmental health department for each individual lot for review and approval. Per the Environmental Health Department, if the lots of a subdivision are to be served by individual subsurface wells, the on-site sewage disposal permit application must indicate the location of the well and on-site sewage disposal system. The subsurface well must be setback at least 100 feet from any on-site sewage disposal system and drainfields.

(h) Stormwater drainage. The subdivider shall provide adequate stormwater drainage in accordance with all applicable county regulations and specifications.

(i) Grassing and erosion control. Proper erosion control measures must be in place throughout the entire phase of construction and must also be in place prior to final plat approval. Permanent grass must also be established on all disturbed areas prior to final plat approval. However, proper temporary erosion control measures and performance bonds can be substituted for a permanent stand of grass during the final plat inspection.

(j) Approval of permits. Building permits may be issued for a phase of a subdivision prior to the completion of the improvements in the entire subdivision, provided that the applicable departments approves the improvements in said phase and it is determined that the lots to be built upon are completely served by the improvements in the completed phase as if it were a separate subdivision.

(k) Utilities. The subdivider shall provide all applicable utilities to the subdivision in accordance with all applicable county requirements. The utilities shall be located as specified by the development regulations. Power and water utilities must be installed, if available in the area, prior to final plat approval. All of the minimum improvements listed in this section of the article must be completed and inspected prior to final plat approval with the exceptions of the installation of utilities in nonresidential subdivisions.

Historia

La línea de historia que la fuente imprime al final de la sección.

(Ord. No. 2020-01, § 1, 5-28-2020; Ord. No. 2021-13, § 4, 9-23-2021)

Leer este código donde se publica (Municode) La fuente es el código de la ciudad tal como lo publica su editorial o su propio sitio web. Consúltelo allí para ver cambios posteriores.

Versión local-code:fayette-county/zoning/104-598@2026-05-28-9d723fda3f

El asistente puede decir lo que dice esta sección en esta edición, citándola y enlazándola. No aplicará la ley a su situación, y nada de esto es asesoría legal.

Fayette County Zoning Ordinance, Sec. 104-598. Minimum requirements | Georgia Commons