(a) Architectural design should be compatible with the developing character of the neighboring area.

Design compatibility includes complementary building style, form, size, color, materials, and detailing.

The designer should consider each of the following contexts as part of the design process:

1. Size (the relationship of the project to its site).

2. Scale (the relationship of the building to those around it).

3. Massing (the relationship of the building's various parts to each other).

4. Fenestration (the placement of windows and doors).

5. Rhythm (the relationship of fenestration, recesses and projections).

6. Setback (in relation to setback of immediate surroundings).

7. Materials (their compatibility with the historic district).

8. Context (the overall relationship of the project to its surroundings).

(b) Efforts to coordinate the height of buildings and adjacent structures are encouraged. This is especially applicable where buildings are located very close to each other. It is often possible to adjust the

height of a wall, cornice or parapet line to match that of an adjacent building. Similar design linkages such as window lines should be placed in a pattern that reflects the same elements on neighboring buildings.

(c) Diversity of architectural design should be encouraged. "Theme" or stylized architecture which is characteristic of a particular historic period or trend is not encouraged, unless the existing building or site is historically important to the district or necessary for architectural harmony.

(d) Multiple buildings on the same site shall be designed to create a cohesive visual relationship between the buildings.

(e) Long or continuous wall planes shall be avoided, particularly in pedestrian activity areas, where buildings should exhibit more detail and elements appropriate for close range pedestrian view. Recesses and projections should be used along the front facade to break up long expanses of wall planes.

(f) Façade articulation.

1. Office, institutional, commercial, and industrial uses. The walls of buildings shall not extend more than 200 linear feet parallel to a

street unless the front façade of the building is designed in a way that breaks up the building face into discrete architectural elements, which can be accomplished through the following:

Facade modulation: stepping back or extending forward a portion of the façade; and/or Providing bay windows or repeating window

patterns at regular intervals; and/or Providing a porch, patio, deck, covered entry to portions of the façade at the ground level, or in the case of buildings containing

two or more story, balconies; and/or Changing the roofline by alternating dormers, or using stepped roofs, gables, or other roof elements; and/or

Changing materials with the change in building plane.

Consistent: Roof planes should be varied to increase visual interest, and awnings above windows and entrances also help to provide visual interest;

Inconsistent: Flat roofs and lengthy, nonarticulated walls;

Consistent:A line of mature trees that almost entirely screens what would otherwise be a large, imposing side wall of a big box;

Inconsistent: The rear side of this shopping center consists of a finished but monotonous wall. Trash receptacles are not enclosed.

2. Multi-family dwellings.Variation in the roofline of buildings and offsets in pitched roofs and gables is required. Facades over 50 feet in length must incorporate projections or recesses a minimum of 12 inches in depth.

The combined length of said projections and recesses must constitute at least 20% of the total façade length. On street-facing façades of any building in a multi-family development, the blank wall area (defined as the portion of the exterior façade of a building

that does not include windows or doors;

pilasters or other articulation greater than 12 inches in depth; or a substantial change in material) shall not exceed 30 feet in either a vertical or horizontal direction. Transparency (defined as the minimum percentage of windows and doors that must cover a ground

or upper story façade) on a street-facing façade of any building in a multi-family development shall be a minimum of 20% on each story.

(g) Outside of pedestrian retail districts, building surfaces over two stories high or fifty feet in length shall be relieved with changes of wall plane (i.e., recesses and projections) that provide strong shadow or visual interest.

(h) All sides of a building may impact on its surroundings and shall utilize an architectural finish of primary materials consisting of real brick (full-depth

or thin brick), unpainted natural stone, unpainted cast stone, true three-coat cement stucco, natural wood or cementious siding including lap siding and board and batten, and wood or cementious shakes and shingles. Front façades shall be at least 50% real brick and/or unpainted natural stone. Side façades shall be at least 50% real brick and/or unpainted natural stone. Rear façades that are visible from a public right-of-way shall be at least 50% real

brick and/or unpainted natural stone. Requirements for brick or stone may be modified to accommodate creatively designed structures as determined by the Community Development Director.

(i) Exterior building materials on the primary structure shall not include smooth-faced concrete block, tilt-up concrete panels, or prefabricated steel panels,

with the exception that exterior building materials on industrial buildings may be split face (integrated block) and/or tilt-up concrete panels accented with steel panels. However, elevations visible from the public right-of-way must be permanent, non-metal construction.

(j) The following types of building materials shall not be used: highly reflective, shiny, or mirror-like materials; mill-finish (non-colored) aluminum metal windows or door frames; exposed, unfinished foundation walls; exposed plywood or particle board; and unplastered, exposed concrete masonry blocks.

(k) Piecemeal embellishment and frequent changes in material shall be avoided. Material or color changes generally shall occur at a change of plane. A horizontal accent stripe (e.g., a foot wide stripe of different color) shall be used to help reduce the monotonous color and break up the appearance of large building walls, and shall be used when there is a change in exterior finish.

(l) Facade colors shall be low reflectance, subtle, neutral, or earth tone colors. High-intensity colors, metallic colors, black, or fluorescent colors shall not be used. Building trim and accent areas on nonresidential buildings may feature brighter colors, including primary colors, provided that the width of the trim shall not exceed four (4) feet.

(m) Building colors should be carefully chosen so that each building complements that of its neighbors.

Colors can be classified as the "base" color (used on the majority of the building surface), "trim" color (used on the window trim, fascia, balustrades, and posts), and "accent" color (used on signs, awnings, and doors). The base color shall consist of more subdued earth tones or brick shades. Trim colors shall have contrasting lighter or darker shade than the base color. If natural brick is used, it shall not be painted.

(n) The use of awnings on buildings are recommended so as to provide much needed protection from sun, wind, and rain, and to improve aesthetics

of the building exterior.

(o) Awnings are recommended to be constructed with a durable frame covered by a canvas material.

Awnings that are backlit through translucent materials may be acceptable but are not particularly encouraged. Aluminum and other metal canopies are acceptable in most instances, particularly when integrated into shopping center designs. Flameproof vinyl, canvas or metal awnings and canopies may be

used.

(p) Solid colors are preferred over striped awnings, but striping is permitted if colors compliment the character of the structure or group of buildings.

(q) Awnings are encouraged for first floor retail uses to provide architectural interest and to encourage pedestrian activity. Where awnings are used, they should be designed to coordinate with the design of the building and any other awnings along the same block face.

(r) The design of fences and walls shall be compatible with the architecture of the main building(s) and should use similar materials. All walls or fences

fifty feet in length or longer, and four feet in height or taller, should be designed to minimize visual monotony though changes in plane, height, material or material texture or significant landscape massing.

Chain link fencing is discouraged. Use of special fencing design or materials should be discussed in cases where site security is paramount. If used, chain link fences should be vinyl coated (black or green colored vinyl encouraged).

(s) All commercial, industrial, large multifamily residential and institutional sites must provide appropriate refuse dumpsters and other similar areas devoted to the storage of waste materials and grease or oil containers. The minimum area for said requirement shall be 36 square feet. All garbage dumpsters and other similar areas devoted to the storage of

waste materials and grease or oil containers should be screened on three (3) sides of said dumpster or area with a minimum six (6) foot high solid wooden fence, or a wall constructed of materials substantially similar in appearance to the building on site. In addition, said dumpster areas should be gated on the fourth side with a material that provides opaque screening, should be screened on three (3) sides of said dumpster or area with a minimum six (6) foot high solid wooden fence, or a wall constructed of materials substantially similar in appearance to the building on site. In addition, said dumpster areas should be gated on the fourth side with a material that provides opaque screening.

(t) Rooftop mechanical and electrical equipment shall be screened from public view by building elements that are designed as an integral part of the building architecture, or by a parapet wall.

(u) Where roof shingles are used, architectural shingles shall be required.

(Ord. No. 348-17, § 1(Exh. A), 8-2-2018; Ord. No.

657, § 1(Exh. A), 12-16-2021)

Leer este código donde se publica (Municode) La fuente es el código de la ciudad tal como lo publica su editorial o su propio sitio web. Consúltelo allí para ver cambios posteriores.

Versión local-code:flowery-branch/zoning/10.7@2026-11-11-476a59d429

El asistente puede decir lo que dice esta sección en esta edición, citándola y enlazándola. No aplicará la ley a su situación, y nada de esto es asesoría legal.

Flowery Branch Zoning Ordinance, Sec. 10.7. Architectural Design | Georgia Commons