(a) Structural Design. New communication towers or poles and antennae, and modifications to existing structures including, without limitation, the

addition of height, antennae or providers, shall be constructed in accordance with applicable federal, state and local regulations.

(b) Placement Restrictions. Towers occupying a lot as a principal use shall at minimum meet the minimum lot size and setback requirements for the zoning district in which the lot is located. Towers shall be a minimum of three-hundred (300) feet from any residential zoning district. The tower shall also be set back from side or rear property lines a distance equal to or greater than the tower height. All towers shall be located at least one-half (1 /2) of their height in feet from any public right-of-way. When the tower is on property leased, the setbacks shall apply to the lot of record, not the lease boundaries.

(c) Screening. The visual impacts of a communication tower at the ground level shall be mitigated by landscaping. All towers and accessory structures

shall be surrounded on the ground by a minimum ten

(10) foot wide landscape strip or buffer that forms a hardy screen dense enough to interrupt vision and shield the base and accessory structures from public view and view from the surrounding properties. The buffer shall consist of evergreens that will reach a minimum height of at least eight (8) feet within three

(3) years.

(d) Fencing. A black vinyl-coated chain link fence or wall not less than six (6) feet in height from finished grade shall be provided around each communication tower or pole. Access to the tower or pole shall be through a locked gate. The tower or pole shall be equipped with an appropriate anti-climbing device, unless the Zoning Administrator waives this requirement for alternative tower structures.

(e) Height. Through approval of a conditional use application, when one is required, the height of the tower may exceed the maximum height limit of the zoning district in which it is located, up to a height of two hundred (200) feet, subject to the limitations of this paragraph. Towers shall be the minimum height necessary to provide parity with existing similar towersupported antenna. No tower, pole, or antenna, whether freestanding or attached to a building or

structure, shall exceed two-hundred (200) feet in height from ground level unless approval is obtained via conditional use permit. To prevail in any conditional use application to exceed established maximum height limitations of this paragraph, the applicant must successfully demonstrate why the prescribed maximum height is insufficient to provide

adequate service, or that a taller tower will be in the community's interest by avoiding the construction of one or more additional towers at a new location.

(f) Illumination. Communication towers, poles, or antennae shall not be lighted except to assure human safety or as required by the Federal Aviation Administration, Federal Communications Commission, or other federal agency with jurisdiction. Lighting shall be restricted to dual lighting, medium intensity white strobe lights (daylight mode), and red obstruction lights (nighttime mode), unless the FAA

or state aeronautics division requires another type of lighting.

(g) Color and Material. Towers clustered at the same site shall be of similar height and design.

Communication towers not required to be painted or marked by the Federal Aviation Administration shall have either galvanized steel finish or be painted a non-contrasting color approved by the Governing Body to minimize the equipment's visibility. If an antenna is installed on a structure other than a tower, the antenna and supporting electrical and mechanical equipment must be of a neutral color that is identical or closely compatible with the color of the

supporting structure so as to make the antenna and related equipment as visually unobtrusive as possible. During the review process, the Governing Body may require the camouflaging of towers where appropriate and feasible.

(h) Signs and advertising. No advertising is permitted on a tower or antenna. However, towers shall have mounted in a conspicuous place a sign of not

more than one (1) square foot in area, identifying the facility's owner and providing a means of contact in the event of an emergency.

(i) Co-location. Proposed communication antennas may and are encouraged to co-locate onto existing communication towers. New or additional conditional use approval is not required for the addition of an antenna to an existing approved tower or pole.

All towers over one-hundred (100) feet in height shall have structural capacity and ground or interior space to accommodate multiple users. Towers up to onehundred sixty (160) feet shall accommodate at least three users, and towers over one-hundred sixty (160)

feet shall accommodate at least five users.

(j) Noninterference. No communication tower or antenna shall interfere with public safety communication. Frequency coordination is required to ensure noninterference with public safety system and/or public safety entities.