Fort Oglethorpe · Ordenanza de zonificación
Appendix A - UNIFIED DEVELOPMENT CODE / Chapter 7 - INFRASTRUCTURE IMPROVEMENTS / Article 4 - STREET CONSTRUCTION STANDARDS
Sec. 4.14. Curbs and gutters.
Sobre este texto
- As published by Municode, current through 2026-03-26
- The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.
Las notas de arriba, el texto de la sección y su línea de historia se muestran en inglés, tal como los publica la fuente y como los da el corpus.
(a) Concrete curb and gutter may be used for public paved streets but it is not required.
If concrete curb and gutter is not used, extruded concrete curbs must be used on public paved streets and extruded concrete curbs shall meet the design standards imposed by this development code and the public works director.
(b) Residential subdivision curb and gutter may be either vertical faced or rollover.
(1) Residential subdivision vertical faced curbing shall have a typical minimum section of six inches by 24 inches by 12 inches.
(2) Residential subdivision rollover curbing shall have a typical minimum section of six inches by 24 inches by nine inches.
(3) The concrete shall have a minimum compressive strength of 3,000 PSI at 28 days.
(4) Vertical faced curb and gutter shall be used at all subdivision entrances, deceleration lanes and downhill culs-de-sac. See Standard Detail 207 "Curb and Gutter Cross Sections."
(c) Nonresidential subdivision curb and gutter may be either vertical faced or rollover.
(1) Nonresidential subdivision vertical faced curbing shall have a typical minimum section of six inches by 24 inches by 12 inches.
(2) Nonresidential subdivision rollover curbing shall have a typical minimum section of six inches by 24 inches by nine inches.
(3) The concrete shall have a minimum strength of 3,000 PSI at 28 days. See Standard Detail 207 "Curb and Gutter Cross Sections."
(d) Parallel curb lines shall be at the same elevation on each side of the street at the same station except for intersections and approved super-elevated sections.
(e) One-half-inch expansion joints or pre-molded bituminous expansion joint material shall be provided at all structures and radius points and at intervals not to exceed 500 feet in the remainder of the curb and gutter. Construction joints shall be provided at intervals not to exceed 20 feet.
(f) Cracks in the concrete are permissible provided that there is no vertical displacement, or that any horizontal displacement shall not exceed one-eighth of an inch.
(g) Graded aggregate base shall be placed under the curb and gutter or the area where curb and gutter is to be placed must pass a proof roll inspection for all roadways that are to be city accepted.
Historia
(Ord. No. 2021-10, § 1, 6-28-2021)
Leer este código donde se publica (Municode) La fuente es el código de la ciudad tal como lo publica su editorial o su propio sitio web. Consúltelo allí para ver cambios posteriores.