Gordon County · Ordenanza de zonificación
Chapter 6 - INFRASTRUCTURE IMPROVEMENTS
6.01.06. Street Design Requirements
Sobre este texto
- As published by Municode, current through 2024-03-19
- The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.
Las notas de arriba, el texto de la sección y su línea de historia se muestran en inglés, tal como los publica la fuente y como los da el corpus.
A. General street design requirements
1. The arrangement of streets shall conform to the official county road map, or, for streets not shown on this plan, shall provide for an appropriate extension of the existing pattern of streets. Roads are classified as follows:
a. Arterial: Minimum pavement width as required and a minimum right-of-way width of one hundred (100) feet;
b. Industrial: Minimum pavement width of twenty-four (24) feet and a minimum right-of-way width of sixty (60) feet;
c. Major Collector: Minimum pavement width of twenty-two (22) feet and a minimum right-of-way width of eighty (80) feet;
d. Minor Collector: Minimum pavement width of twenty-two (22) feet and a minimum right-of-way width of sixty (60) feet;
e. Local: Minimum pavement width of twenty (20) feet and a minimum right-ofway width of fifty (50) feet; and
f. Alley: Minimum pavement width of twelve (12) feet and a minimum right-ofway width of twenty (20) feet.
2. Where a subdivision fronts on one (1) side of an existing road which does not meet the minimum requirements contained in these regulations, the developer shall provide one-half (1
/2) of the required right-of-way necessary to upgrade the road.
Should the subdivision front both sides of the existing road, the developer shall provide all necessary right-of-way required to bring the road into conformity with these regulations.
3. Where a subdivision or any development located outside the jurisdictional limits of Gordon County fronts an existing County road, the developer shall meet the criteria established in this ULDC. An exception may be granted only by the Gordon County Public Works Director.
4. The minimum right-of-way as required by this section must be shown on the final plat and shall be dedicated to and accepted by the County if the proposed development meets the criteria established by this section and other development regulations of the County. Such road or street must be inspected by the County Public Works Department for compliance with this section. All building setback requirements shall be measured from this established right-of-way line.
5. Traffic studies shall be required for all residential subdivisions containing more than four hundred (400) lots, and on nonresidential subdivisions generating more than four thousand (4,000) ADT. Such studies will, at a minimum, address the level of traffic generated by the proposed development and its distribution on the existing road network; and the need for acceleration lanes, deceleration lanes, left turn lanes, other additional lanes and traffic signals on all existing and proposed roadways.
6. All streets with curb and gutter shall be constructed with a minimum thirteen-foot shoulder behind both curbs. See Standard Detail 201, "Residential Streets" and Standard Detail 202, "Nonresidential Streets."
7. All streets shall have a minimum centerline grade of at least 0.5 percent except for cul-de-sacs and intersections, which shall have a minimum centerline grade of at least 1.0 percent.
8. Super-elevated curves shall be provided as per Georgia Department of Transportation design guidelines for arterial streets.
9. Where a deflection angle of more than ten (10) degrees occurs, a horizontal curve of reasonably long radius shall be introduced.
10. The minimum length of crest vertical curves shall be one hundred (100) feet.
Longer lengths may be required based on required stopping sight distance. The sight distance for crest vertical curves shall be measured along the roadway from three and one-half (31
/2) feet above the pavement to an object six (6) inches high, as discussed in the current AASHTO policy on design. Vertical curves may be designed to extend past the end of a cul-de-sac provided stopping sight distance is met. See Standard Detail 203,"Minimum Stopping Sight Distance."
11. The minimum length of sag vertical curves shall be one hundred (100) feet. Vertical curves may be designed to extend past the end of a cul-de-sac provided stopping sight distance is met.
12. Sight distances at intersections shall be determined by the posted speed limit of the street (existing County road or state highway) onto which a vehicle must turn.
Such distances shall be measured beginning from a point established ten (10) feet behind the back of the curbline on the centerline of the egress lane at a height of three and one-half (31
/2) feet above the finish grade elevation. The line of sight is then extended the minimum required distance to either side of the abutting street along the thoroughfare to the edge of the oncoming traffic lane, terminating at a point three and one-half (31
/2) feet above the finish grade elevation. See Standard Detail 204, "Intersection Sight Distance."
13. Roads may be constructed across an existing or proposed dam. The appropriate state approved professional shall provide a report certifying that the existing or proposed dam is structurally capable of supporting the road. Any road across a dam shall be a service road. Ingress and egress easements, not right-of-way, shall be granted. A second point of access to the subdivision across a public must be provided. The section of road across the dam, and the dam itself, shall be maintained by the developer, his heirs, executors, administrators, or assigns, or a mandatory homeowners' association established for maintenance and other purposes.
B. Residential street design requirements (local streets)
1. All local streets, excluding such streets in A-1 and RA-1 zoning districts, shall be constructed with curb and gutter. Residential subdivision curb and gutter may be either vertical faced or rollover.
2. Apartment and condominium development streets shall be designed and constructed to the same standards as other residential streets.
3. The following residential street design standards shown in Table 6.01.06(A) shall apply to all streets in residential subdivisions. See Standard Detail 201, "Residential Streets." Design requirements for arterial and collector streets in residential subdivisions shall be based on AASHTO and Georgia DOT standards, and approved by the County. An alley street is allowed in residential zoning districts and in the MU district to provide rear access to a primary dwelling and shall have a minimum right-of-way width of twenty (20) feet and a minimum pavement width of twelve (12) feet.
Table 6.01.06(A) Residential Street Design Requirements Residential Street (Local) Minimum right-of-way width, in feet 50 Minimum pavement width, in feet 20 Minimum pavement width, in feet, in A-1 and RA-1 zoning districts, without curb and gutter
22 Minimum lane width, in feet 10 Residential Street (Local) Minimum lane width, in feet, in A-1 and RA-1 zoning districts, without curb and gutter
11 Maximum grade 15% Minimum stopping sight distance, in feet 160 Design speed, in mph 25 Minimum radius of centerline curvature, in feet 100 Minimum length of tangent between reverse curves, in feet 0 Minimum sight distance at intersections (each way), in feet 200 Minimum length sag vertical curves, in feet 100
Minimum length crest vertical curve, in feet 100 Internal subdivision street curb or edge of pavement radius, in feet 25
C. Nonresidential street design requirements
1. Nonresidential streets shall be classified into a street hierarchy for design and construction purposes. Street design standards in nonresidential subdivisions shall be based on road function and the average daily traffic (ADT) the street will accommodate, as determined in the current edition of ITE's Trip Generation manual. Nonresidential street classes and their corresponding ADT thresholds are: Nonresidential: 1-10,000 ADT.
2. Arterial or collector streets shall be required when ADT generated by the development will exceed ten thousand (10,000) daily trips. Street design requirements for arterial and collector streets shall be based on AASHTO and Georgia DOT standards, and approved by the County.
3. Nonresidential street classifications and design standards may be changed at intersections on any street to reflect the lot size and dwelling unit thresholds. Jogs in the centerline, pavement or right-of-way shall not be permitted.
4. The applicant shall demonstrate to the County that the distribution of traffic to the proposed street system shall not exceed the ADT thresholds for any of the proposed street classifications.
5. All nonresidential streets shall be constructed with curb and gutter, except for those nonresidential streets serving developments where the minimum lot size is five (5) acres or larger. Nonresidential subdivision curb and gutter may be either vertical faced or rollover.
6. The following nonresidential street design standards shown in Table 6.01.06(B) shall apply to all public and private streets constructed in nonresidential subdivisions. See Standard Detail 202, "Nonresidential Streets." The minimum standard for nonresidential subdivision street design and construction shall be a nonresidential street.
Table 6.01.06(B) Nonresidential Street Design Requirements Nonresidential Minimum right-of-way width, in feet 60 Minimum pavement width, in feet 24 Minimum lane width, in feet 12 Maximum grade 14% Minimum stopping sight distance, in feet 250 Design speed, in mph 35 Minimum radius of centerline curvature, in feet 440 Minimum length of tangent between reverse curves, in feet 100 Minimum sight distance at intersections (each way), in feet 325 Minimum length sag vertical curves, in feet 100
Minimum length crest vertical curve, in feet 100 Internal subdivision street curb radius, in feet 40
D. Intersections
1. Street intersections shall be as nearly at right angles as possible, but in no case shall a street intersection be at an angle of less than seventy (70) degrees. The one hundred ten (110) degree angle of the intersection should be directed towards the approach with the highest volume of traffic.
2. Interior street jogs or intersections shall have centerline offsets of a minimum of one hundred twenty-five (125) feet. Exterior street jogs or intersections shall have centerline offsets of a minimum of two hundred fifty (250) feet.
3. Islands at intersections shall meet sight distance requirements established by AASHTO and shall be subject to individual approval by the County. Anything extending more than three (3) feet above the top of the curb within the right-of-way of the intersecting streets shall require approval by the road superintendent.
4. A utility easement shall be provided at all street intersections. This easement shall form a triangle with two (2) twenty (20) foot legs of the triangle leading away from the street right-of-way intersection. This easement miter shall be graded a minimum of thirteen (13) feet back from the intersecting right-of-way lines to provide for utility line placement (twenty-five (25) feet for overhead utilities).
E. Cul-de-sacs
1. All permanent dead-end streets shall be constructed as cul-de-sacs with a turnaround provided at the closed end.
2. Residential cul-de-sacs shall have a right-of-way radius of at least sixty (60) feet, and pavement radius of at least forty-five (45) feet, as measured to the back of the curb or edge of pavement if not curbed. See Standard Detail 205, "Cul-de-sac Details."
3. Nonresidential cul-de-sacs shall have a right-of-way radius of at least seventy-five
(75) feet, and a pavement radius of at least sixty (60) feet, as measured to the back of the curb. See Standard Detail 205, "Cul-de-sac Details."
4. If a street is planned to be terminated as a cul-de-sac the subdivider may not utilize a vacant lot to extend the street to an adjacent property without proper notification to affected property owners. Such a change in the construction plans shall be considered a variance and must be submitted to the Board of Zoning Appeals for review and approval.
5. Streets that terminate in a cul-de-sac shall be a maximum of one thousand two hundred (1,200) feet in length.
6. Cul-de-sacs may have central landscaped islands with a minimum pavement radius of fifty (50) feet and a minimum twenty (20) feet wide paved area in the radius.
F. Reserved
G. Development entrances
1. All proposed subdivision developments, both residential and nonresidential, where a new entrance is provided from an existing County road, shall construct such entrance subject to the requirements as provided for in Standard Detail 206A for residential subdivision intersections and as provided for in Standard Detail 206B for commercial/industrial subdivision intersections.
2. Any residential subdivision accessed by a County road shall conform to Standard Detail 206A "Street Details: Residential Subdivision Intersection".
3. Any nonresidential subdivision containing businesses which will generate more than 500 ADT, as determined by the current edition of ITE's Trip Generation manual, shall install a full deceleration lane, offset radii and tapers. Nonresidential subdivisions with 500 ADT or less shall construct an entrance as noted in Standard Detail 206B for commercial/industrial subdivision intersections.
4. Access onto a state road shall meet existing Georgia DOT requirements. A copy of the Georgia DOT permit shall be submitted to the County before the plans can be approved.
5. Deceleration lane and taper length shall be based on the main roadway posted speed limit as shown in Table 6.01.06(C) below. The County shall require residential subdivisions exceeding two hundred (200) lots to install longer deceleration lanes and/or a center turn lane.
Table 6.01.06(C) Deceleration Lane and Taper Requirements Main Road Speed Limit Deceleration Lane Length Transition Taper Length 55 mph 200' 50'
50 mph 150' 40' 45 mph 110' 35' 40 mph 90' 30' 35 mph 50' 25'
6. The minimum pavement width of a deceleration lane shall be twelve (12) feet, and the minimum turning radius shall be twenty-five (25) feet. The County may require a lane width greater then twelve (12) feet if the existing County road has insufficient pavement width to meet current requirements. The minimum pavement design for subdivision entrances through the point of tangency on the proposed street shall be eight and one-half (81
/2) inches.
7. Additional street right-of-way necessary for deceleration lanes shall be dedicated as needed, and as illustrated in Standard Details 206A and 206B.
8. The cross slope of any deceleration lane shall follow the crown or super elevation of the existing street.
9. In cases involving rock cuts, deep fills or cuts, proximity to a floodplain, or other constraints to construction, the requirements for pavement widening for a full deceleration lane may be waived by the County.
10. Vertical faced curb and gutter are required through the radius, excluding the tapers.
11. The developer shall be responsible for the costs of any utility relocation or catch basins which must be constructed.
H. Temporary turnarounds
1. Stub-out streets shall not be allowed, except at phase lines or by the approval of the Director of the Gordon County Public Works Department, for the purpose of allowing connectivity between developments. A temporary turnaround is required when the street length exceeds the minimum width of one (1) lot permitted under the applicable zoning district.
2. A temporary turnaround shall be maintained for a period not to exceed twenty-four
(24) months. All such turnarounds shall, at a minimum, be constructed with six (6) inches of graded aggregate base, and have a minimum driving radius of thirty (30) feet.
3. Where temporary turnarounds are permitted, the County shall require a performance guarantee for completion of a cul-de-sac. The County shall also require that the final plat record sufficient right-of-way to construct a permanent cul-de-sac.
Such right-of-way will revert to typical street right-of-way when the street is extended.
I. Traffic control devices
1. All required street name signs, traffic control signs and other traffic control devices shall be installed at the developer's expense, meet County specifications for such devices, and may be installed by the County. If the developer elects to have the County provide and install such devices, in no event shall the cost be less than the actual cost incurred by the County.
2. The design and placement of all traffic control devices shall meet the requirements of the Manual on Uniform Traffic Control Devices published by AASHTO. The design professional shall show the placement of all required street markers.
3. If nonstandard markers are installed, the developer, or homeowners' association established by the developer, shall be responsible for the perpetual maintenance of these markers. All nonstandard markers shall be approved by the County prior to installation.
4. Fire hydrant location devices shall be installed at the expense of the developer, and shall meet appropriate water department standards and fire department standards.
J. Sidewalks
1. Sidewalks shall be required in all new developments within a mixed use zoning district and any commercial, office, and institutional zoning district. Sidewalks shall also be required on all existing vacant lots, parcels, or tracts of land within any commercial, office, and institutional zoning district upon their development;
and on any existing developed lot, parcel, or tract of land involving the renovation of or addition to an existing building which the cost thereof exceeds fifty (50) percent of the ad valorem tax value as established by the current digest at the time the proposed renovations and/or building additions begin or are contemplated.
2. Sidewalks are permissible, but not required, in residential zoning districts.
Installation shall be in accordance with the provisions of this section.
3. Sidewalks shall be placed, at a minimum, on one side of the street on the interior of a development and along the entire perimeter of a development that fronts a public street. Sidewalks that are located on only one side of the street on the interior of a development shall be located where there are fewer utility conflicts.
4. Sidewalks located in the interior of a development within commercial, office, institutional and mixed use zoning districts are required along the perimeter of the front facade of a building and along any facade that has a public entrance. Corner entrances require sidewalks along each intersecting facade.
5. Sidewalk construction shall follow a logical design approved by the County. The design shall be in accordance with the American Association of State Highway and Transportation Officials (AASHTO) "A Policy on Geometric Design of Highways and Streets," Georgia Department of Transportation (GDOT) specifications, and with design and location standards required herein.
6. Sidewalks shall be a minimum width of five (5) feet.
7. Access ramps are to be placed at all drives, intersections, and all curb encroachments; all ramps and be constructed/installed in compliance with the Americans with Disabilities Act (ADA).
8. Maintenance of sidewalks shall be the responsibility of the developer or property owner.
K. Blocks
1. The length, width and shape of blocks shall be appropriate for the environment and the type of development proposed.
2. In long blocks, the County may require the reservation of an easement through the block to accommodate utilities, drainage facilities, or pedestrian traffic.
Leer este código donde se publica (Municode) La fuente es el código de la ciudad tal como lo publica su editorial o su propio sitio web. Consúltelo allí para ver cambios posteriores.