Sec. 717. Shopping centers.

Sobre este texto

  • As published by Municode, retrieved 2026-11-11
  • The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.

Las notas de arriba, el texto de la sección y su línea de historia se muestran en inglés, tal como los publica la fuente y como los da el corpus.

Shopping Centers are defined as a group of three or more retail stores or shops under single ownership or management or owned individually as condominium unit. Shopping Centers are special permit uses in C-2 District and shall comply with the requirements of special uses and the following additional standards. The applicant shall submit a site plan containing all the relevant information in order for the Planning and Zoning Commission and City Council to determine that the proposed development meets the requirements of this ordinance.

(1) There shall be no more than two access points to any one public street. All entrance and exit points shall be located to afford maximum safety to traffic, provide for safe and convenient ingress and egress to and from the site and to minimize conflict with the flow of traffic.

(2) Any exit driveway shall be so designed so as to provide the following minimum sight distance measured in each direction. The measurements shall be from the driver's seat of a vehicle standing on that portion of the exit driveway with the front of the vehicle a minimum of ten feet behind the curb line or edge of shoulder with the height of the eye three and seventy-five hundredths (3.75) feet to the top of an object four and five-tenths (4.5) feet above the pavement.

| | | |-----------------|-------------------------| | Allowable Speed | Required Sight Distance | | 25 | 160 | | 40 | 275 | | 45 | 325 | | 50 | 350 | | 55 | 425 |

(3) Where a site occupies a corner of two intersecting roads, no driveway entrance or exit shall be located within fifty (50) feet of the point of tangency of the existing or proposed curb radius of that site.

(4) No part of any driveway shall be located within a minimum of ten (10) feet of a side property line. However, the Planning and Zoning Commission/City Council may permit a driveway serving two or more adjacent sites to be located on or within ten (10) feet of a side property line between adjacent sites.

(5) If the proposed shopping center is adjacent to another shopping or commercial property, the Commission/Council may require connection of parking areas so as to alleviate use of the public street for traffic movement between properties.

(6) Driveways shall intersect the road at an angle of as near ninety (90) degrees as site conditions will permit and in no case less than sixty (60) degrees.

(7) The dimensions of the driveways shall be designed to accommodate adequate volume and character of vehicles anticipated to be attracted daily to the development. The following are the minimum widths:

| | | |--------------------|---------| | One-way driveways: | 15 feet | | Two-way driveways: | 25 feet |

(8) Any driveway shall be constructed with the surface approved by the Commission/Council. Such surface shall extend to the paved portion of the road and shall extend throughout the area defined by the required driveway dimensions.

(9) Where a driveway serves right-turning traffic from a parking area providing two hundred (200) or more parking spaces and the road has an average daily traffic volume exceeding seven thousand five hundred (7,500) vehicles, an acceleration lane and a deceleration lane for each connection is required. Each shall be two hundred (200) feet in length and ten (10) feet wide. A minimum thirty-five (35) foot curb return radius shall be used for each.

(10) Parking shall be provided as required in Article Eight. Parking aisles which provide direct access to individual parking stalls shall be twenty-five (25) feet wide. All parking shall be ninety (90) degrees (perpendicular) from the aisles.

(a) Parking areas should be designed to focus on major walkways, which should be fenced or marked.

(b) Where pedestrians must cross service roads or access roads to reach parking areas, crosswalks should be clearly designed by pavement markings or signs and lighted. Crosswalk surfaces should be raised slightly to be distinguished from driveways, unless drainage problems would result.

(11) Exterior lighting shall meet the following requirements:

(a) The style of the light and the light standard shall be consistent with the architectural style of the principal building.

(b) The maximum height of freestanding lights shall be no more than twenty-five (25) feet.

(c) All sights shall be shielded to restrict the maximum apex angle of the cone of illumination to one hundred fifty (150) degrees.

(d) Where lights along property lines will be visible to adjacent residents, the lights should be appropriately shielded.

(e) Spotlight-type fixtures attached to buildings are not permitted.

(f) The following intensity in footcandles should be provided:

1. Parking lots: an average of 1.5 footcandles throughout;

2. Intersections: Three (3) footcandles;

3. Maximum at property lines: One (1) footcandle.

(12) Buffer and landscaping shall be required as follows:

(a) Buffers or fences, landscaping, berm and mounds used to minimize any adverse impacts or nuisance on the site or from adjacent areas. Buffers are required where a shopping center abuts a residential use or district;

(b) Natural plants can be used as buffers, if the existing natural plants are sufficient to block the view of the new shopping center. New plantings can be used if they are of sufficient size and character to substantially block the view of the shopping center from the residential area;

(c) Landscaping is required for all shopping centers. For each 24 parking spaces, there shall be required adjacent to the parking spaces, three canopy trees, two understory trees and six shrubs;

(d) Unless otherwise specifically indicated by the Planning and Zoning Commission, all plant materials required shall meet the following minimum size standards:

| | | |-----------------|------------------| | Canopy tree | 2 ½ caliper | | Understory tree | 4 feet in height | | Shrub | 2 feet in height |