Harlem · Ordenanza de zonificación
Part III - LAND DEVELOPMENT CODE / Chapter 108 - LAND USE / Article III - YARD AND HEIGHT REQUIREMENTS
Sec. 108-66. General provisions.
Sobre este texto
- As published by Municode, retrieved 2026-11-11
- The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.
Las notas de arriba, el texto de la sección y su línea de historia se muestran en inglés, tal como los publica la fuente y como los da el corpus.
(a) General. The following area, yard, height and size restrictions shall apply to these districts enumerated in sections 108-44 through 108-46. If side yards are provided in the B-1, B-2, or I-1 districts, they should not be less than ten feet in width. If closed courts are provided in any building, the minimum width of the court should not be less than 25 percent of the height of the building. The front yard setback and the side yard requirements as applied to the A-1 Agricultural District pertain to any building incidental to agriculture.
TABLE I. AREA, YARD AND HEIGHT REQUIREMENTS
Minimum Lot Size Minimum Front Yard Setback from Property Line District Area Residential structures per property lot Lot Width in feet Major Street Other Street Minimum Side Yard in feet Maximum Height in feet Square feet of Principal Structure R-1A 20,000 square feet 1 100 75 55 15 35 1,400 R-1B 10,000 square feet 1 80 75 40 12.5 35 1,400 R-2 20,000 square feet 2 60 75 55 15 35 2,400 R-3 10 acres TBD 60 75 55 15 60 1,100 R-4 ** 1 ** 25 25 10 35 1,100 P-1 ** ** ** 45 25 10 35 ** B-1 ** ** ** 5 5 ** 100 ** B-2 ** ** ** 60 50 15 35 ** B-3 ** ** ** 60 50 10 35 ** I-1 ** ** ** 75 60 15 100 ** A-1 5 acres 1 ** 75 60 15 ** **
PUD 1 25 25 12.5
TNY-R 1 25 25 12.5
CP-R 1 25 25 12.5
MUD TBD 25 25 12.5
SCM TBD 25 25 12.5
*All permanent structures must be no less than 25 feet from the rear property.
TBD: To be determined through the application process as multiple residential types may be proposed.
(b) Height limitations; exemptions. No building or structure shall hereafter be erected or altered so as to exceed the height limits established by this article for different types of buildings and structures. The height limitations of this article shall not apply to church spires, belfries, cupolas and domes not intended for human occupancy, flagpoles, or public utility facilities.
(c) Maximum height limitations. The following maximum heights are established for types of land uses.
TABLE II. MAXIMUM HEIGHT LIMITATIONS
Land Use Maximum Height in feet Single-family dwellings, detached, including manufactured homes 35 Offices and institutions 40 Business and commercial uses 50 Industrial and manufacturing uses 100 Transmission towers 100
(d) Variances to maximum height limitations. The city council may authorize a building or structure to exceed the maximum height limitations for good cause shown, upon application by the owner of the property involved, after a public hearing.
(e) Height performance standard. This section provides for additional setback protection from visual impacts of taller buildings. The heights of buildings on properties abutting a single-family dwelling, including a manufactured home, shall be limited according to the provisions of this section. When a non-residential building or structure is proposed to be erected on property that abuts property containing one or more single-family dwellings or manufactured homes, the height of the nonresidential building or structure abutting one or more single-family dwellings or manufactured homes shall meet the requirements of this section. The height of a non-residential building or structure on property abutting a singlefamily dwelling shall not exceed 35 feet; provided, however, that said non-residential building or structure may be increased in height beyond the 35-foot maximum by one foot for every five feet the nonresidential building is setback from the minimum required side or rear building setback, or ten feet from the side or rear property line if no required side or rear yard is established, up to a maximum required setback of 100 feet. (See figure 5.0.A.) The following table provides maximum heights at five-foot increments of building height based on this performance standard.
TABLE III. HEIGHT PERFORMANCE STANDARDS
Height of Building Abutting a Single-Family Dwelling or Manufactured Home in Feet Additional Building Setback From Required Side or Rear Yard (or Measured Ten Feet From Property Line if No Required Side or Rear Yard is Established) 40 25
45 50 50 75 55 100 (Code 2004, § 152.055; Ord. No. 381, 4-10-2006; Ord. No. 2207, 4-25-2022; Ord. No. 2227, 11-28-2022; Ord. No. 2232, 12-19-2022; Ord. No. 2233, 2-27-2023)