(a) Applicability. This section applies to all accessory solar energy systems except for ground-mounted systems with coverage of greater than 50 percent of the footprint of the principal structure on lot, which are treated as principal solar energy systems.
(1) Solar energy systems constructed prior to the effective date of the ordinance from which this chapter is derived shall not be required to meet the requirements of this section.
(2) Any upgrade, modification, or structural change that materially alters the size or placement of an existing solar energy system shall comply with the provisions of this chapter. Even if they are deemed accessory to the principal use of a property, groundmounted systems covering an area equivalent to more than 50 percent of the footprint of the primary structure on the property are regulated as principal solar energy systems, with requirements set out in section 110-8.
(b) General requirements. The installation and construction of an accessory solar energy system shall be subject to the following development and design standards:
(1) An accessory solar energy system is permitted in all zoning districts as an accessory to a principal use.
(2) A solar energy system connected to the utility grid shall provide written authorization from the local utility company acknowledging and approving such connection.
(3) An accessory solar energy system may be roof-mounted, ground-mounted, parkingmounted, or any combination of the three, provided the system meet the supplemental requirements pertaining to accessory solar energy systems.
(c) Dimensional requirements.
(1) Minimum lot sizes. There is no minimum lot size requirement for an accessory solar energy system.
(2) Setbacks.
a. Ground-mounted systems may be located within required building setbacks.
b. The minimum solar energy system setback distance from the property lines shall be equivalent to the accessory building setback requirement of the underlying zoning district.
c. With respect to building-mounted systems, only building-integrated and/or flushmounted solar energy systems may be installed on street-facing building elevations.
d. In residential zoning districts, a ground-mounted system, parking-mounted system, or system attached to an accessory building shall not be located within a required street setback or street/front yard. This restriction shall also apply to the side yard in any residential district. Any side yard application shall be subject to approval by a locally appointed and elected body as part of the application process.
(3) Height.
a. A building-mounted system may be mounted on a principal building or accessory building. A building-mounted system, whether mounted on the principal building or accessory building, may not extend more than ten feet above the highest point of the roof line of a flat roof and not above the roof line of any other roof, such as, but not limited to, gable, gambrel, or hip roofs.
b. A building-mounted system may not extend more than ten feet beyond the maximum principal building height or accessory building height specified for the building type in the underlying zoning district. In no instance shall any part of the solar energy system extend beyond the edge of the roof.
c. Ground-mounted and parking-mounted systems shall not exceed the maximum building height for accessory buildings. If no height limit is specified for accessory buildings, ground-mounted or parking-mounted systems may not exceed 20 feet in height.
(d) Parcel or building coverage.
(1) Building-mounted systems may cover any amount of a roof but may not extend beyond the roofline.
(2) Accessory ground-mounted systems may cover an area no larger than 50 percent of the footprint of the principal structure on the parcel. Any larger and the system is treated as a principal solar energy system.
(3) Parking-mounted systems shall only cover paved surfaces intended for parking. Nonresidential driveways may not be covered by parking-mounted systems.
(4) Only building integrated systems shall be installed on residential-type roofs visible from public rights-of-way.
(e) Screening. All mechanical equipment associated with and necessary for the operation of the solar energy system shall comply with the following:
(1) Mechanical equipment for nonresidential systems shall be screened from any adjacent property that is residentially zoned or used for residential purposes. The screen shall consist of shrubbery, trees, or other non-invasive plant species which provide a visual screen. In lieu of a planting screen, a decorative fence may be used.
(2) Mechanical equipment shall comply with the setbacks specified for accessory structures in the underlying zoning district.
(f) Historic districts. Accessory solar energy systems on buildings or properties within federal, state, or locally designated historic districts or on locally designated historic buildings will require a certificate of appropriateness unless the installation is not visible from the street.
A certificate of appropriateness from the city historic preservation commission shall be an essential component of any application.
(g) Other considerations.
(1) Accessory solar energy systems must comply with all applicable building and electrical code requirements as adopted by the state department of community affairs.
(2) Owners of accessory solar energy systems are solely responsible for negotiating with other property owners for any desired solar easements to protect access to sunlight.
Any such easements must be recorded with the county clerk of superior court.
(3) Solar panels shall be placed such that concentrated solar radiation or glare shall not be directed onto nearby properties or roadways.
(4) Solar panels shall not be placed in the vicinity of any airport in a manner that would interfere with airport flight patterns. Acknowledgment from the Federal Aviation Administration will be necessary.
(5) All power transmission lines from a ground-mounted solar energy system to any building or other structure shall be located underground unless precluded by building codes adopted by the state department of community affairs.
(6) A solar energy system shall not be used to display advertising, including signage, streamers, pennants, spinners, reflectors, ribbons, tinsel, balloons, flags, banners or similar materials. The manufacturers and equipment information, warning, or indication of ownership shall be allowed on any equipment of the solar energy system provided they comply with the prevailing sign regulations.
(7) The design of the solar energy system shall conform to applicable industry standards.
The local utility provider shall be contacted to determine grid interconnection and net metering policies.
(h) Approvals and permits.
(1) All accessory solar energy systems shall require administrative plan approval resulting in a building permit.
(2) All accessory solar energy systems shall require a building permit.
(3) A solar energy system shall not be constructed until a building permit has been issued following a zoning review.
(i) Plan applications.
(1) Plan applications for accessory solar energy systems shall be accompanied by to-scale horizontal and vertical (elevation) drawings. The drawings must show the location of the system on the building or on the property for a ground-mounted system, including the property lines.
(2) For all building-mounted (non-flush-mounted) systems, the elevation must show the highest finished slope of the solar collector and the slope of the finished roof surface on which it is mounted.
(j) Administrative variance. This Code encourages the installation of productive solar energy systems and recognizes that a balance must be achieved between character and aesthetic considerations and the reasonable desire of building owners to harvest their renewable energy resources. Where the standards in this chapter cannot be met without diminishing, as defined below, the minimum reasonable performance of the solar energy system, an administrative variance may be sought from the community development director or his designee. An administrative variance shall be granted if the administrative variance standards are met.
(1) Minimum performance design standards.The following design considerations are needed for the efficient operation of a solar energy system:
a. Fixed-mount active solar energy systems. Solar energy systems must be mounted to face with 45 degrees of south (180 degrees azimuth).
b. Solar electric (photovoltaic) systems. Solar electric (photovoltaic) systems must have a pitch that is within 20 degrees of latitude, a pitch of between 20 and 65 degrees.
c. Solar hot water systems. Solar collectors must be mounted at a pitch between 40 and 60 degrees.
(2) Standards for an administrative variance. A variance shall be granted by the community development director or his designee if the applicant demonstrates that the following safety, performance and aesthetic conditions are met:
a. Aesthetic conditions. The solar energy system must be designed to blend into the architecture of the building or be screened from routine view from public rightsof-way other than alleys to the maximum extent possible while still allowing the system to be mounted for efficient performance.
b. Safety conditions. All applicable health and safety standards are met.
Historia
(Ord. No. 1802, § 156.009, 3-26-2018)
Leer este código donde se publica (Municode) La fuente es el código de la ciudad tal como lo publica su editorial o su propio sitio web. Consúltelo allí para ver cambios posteriores.