All single-family detached and two-family dwellings shall meet or exceed the following requirements:

a. Each dwelling shall be connected to a potable water supply and sanitary sewage disposal system approved by the Pulaski County Health Department.

b. Foundation:

(1) The structure shall be attached to a permanent foundation constructed in accordance with the Building Code.

(2) Upon placement, all means of transportation, such as chassis, towing devices, wheels, axles, and hitches, shall have been removed.

(3) The area beneath the structure shall be enclosed around the exterior of the structure with masonry, including but not limited to brick, concrete, or rock, penetrated by openings only for installed vents and access doors.

c. Exterior siding: Exterior siding materials shall consist of wood, brick, stone, concrete, stucco, or similar materials, or lap siding of Masonite, metal, vinyl or similar materials, or any combination of the above.

d. Roofs:

(1) All roof surfaces shall have a minimum pitch of 4:12 (4 inches of rise for every 12 inches of run), except that mansard and gambrel roofs must meet this requirement only for those surfaces that rise from the eaves.

(2) All roof surfaces exposed to view shall be covered with asphalt or fiberglass shingles, wood shakes or shingles, standing seam (noncorrugated) tin, clay tiles, slate, or similar materials.

e. The minimum width of the structure shall be greater than twenty-four (24) feet.

f. The Building Inspector may approve deviations from the requirements of this Section on the basis of a finding that the materials to be utilized or the architectural style proposed for the dwelling unit will be compatible with and harmonious or superior to existing structures in the vicinity, and that such deviation shall be consistent with the intent of these regulations.

g. The dwelling shall be constructed in accordance with all applicable requirements of the Building Code as adopted by the City, or in accordance with standards established by the National Manufactured Housing Construction and Safety Standards Act for manufactured homes, or the Georgia Industrialized Buildings Act for residential industrialized buildings.

h. All portions of the structure shall be manufactured or constructed on site with the original intent of combination into a single structure.

Historia

La línea de historia que la fuente imprime al final de la sección.

(Ord. of 5-10-96)