Hawkinsville · Ordenanza de zonificación
Appendix A - UNIFIED LAND DEVELOPMENT REGULATIONS / Article V - LAND DEVELOPMENT ACTIVITIES / Division 7 - GROUNDWATER RECHARGE PROTECTION
Sec. 5.7.5. Criteria in significant recharge areas.
Sobre este texto
- As published by Municode, retrieved 2026-11-11
- The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.
Las notas de arriba, el texto de la sección y su línea de historia se muestran en inglés, tal como los publica la fuente y como los da el corpus.
The following criteria pursuant to § O.C.G.A. § 12-2-18 shall apply in significant recharge areas:
(a) The Department of Natural Resources shall not issue any permits for new sanitary landfills not having synthetic liners and leachate collection systems.
(b) The Department of Natural Resources shall not issue any new permits for the land disposal of hazardous wastes.
(c) The Department of Natural Resources shall require all new facilities permitted or to be permitted to treat, store, or dispose of hazardous waste to perform such operations on an impermeable pad having a spill and leak collection systems.
(d) New above-ground chemical or petroleum storage tanks having a minimum volume of six hundred sixty (660) gallons, shall have secondary containment for one hundred ten
(110) percent of the volume of such tanks or one hundred ten (110) of the volume of the largest tank in a cluster of tanks. (Note: These figures are consistent with U.S. EPA rules for oil pollution prevention, 40 CFR 112.1). Such tanks used for agricultural purposes are exempt, provided they comply with all federal requirements.
(e) New agricultural waste impoundment sites shall be lined if they are within:
1. A high pollution susceptibility area;
2. A medium pollution susceptibility area and exceed fifteen (15) acre-feet;
3. A low pollution susceptibility area and exceed fifty (50) acre-feet.
(f) New wastewater treatment basins shall have an impermeable liner approved by EPD.
(g) No new stormwater infiltration basins may be constructed.
(h) Wastewater spray irrigation systems or the land spreading of wastewater sludge shall be practiced in accordance with Department of Natural Resources criteria for slow rate land treatment. An application for a development permit for activities involving wastewater spray irrigation or land spreading of wastewater sludge must be accompanied by proof that the applicant has received a Land Application System permit from the Georgia Environmental Protection Division.
(i) New homes served by septic tank/drain field systems shall be on lots having the following minimum size limitations as identified on Table MT-1 of the Department of Human Resources' Manual for On-Site Sewage Management Systems (hereinafter "DHR Table MT-1"):
1. 150% of the subdivision minimum lot size of DHR Table MT-I if they are within a high pollution susceptibility area; and
2. 125% of the subdivision minimum lot size of DHR Table MT-I if they are within a medium pollution susceptibility area.
3. 110% of the subdivision minimum lot size of DHR Table MT-1 if they are within a low pollution susceptibility area.
(j) New mobile home parks served by septic tank/drain field systems shall have lots or spaces having the following size limitation as identified on Table N/IT-2 of the Department of Human Resources' Manual for On-Site Sewage Management Systems (hereinafter "DHR Table MT-2"):
1. 150% of the subdivision minimum lot or space size of DHR Table MT-2 if they are within a high pollution susceptibility area;
2. 125% of the subdivision minimum lot or space size of DHR Table MT-2 if they are within a medium pollution susceptibility area; and
3. 110% of the subdivision minimum lot or space size of DHR Table MT-2 if they are within a low pollution susceptibility area.
TABLE 1. Minimum Lot-Size Requirements.
Pollution Susceptibility New Homes Served by Septic Systems New Mobile Homes Served by Septic Systems High 150% of minimum lot sizes specified in DHR Table MT-1 150% of minimum lot sizes specified in DHR Table MT-2 Medium 125% of minimum lot sizes specified in DHR Table MT-1 125% of minimum lot sizes specified in DHR Table MT-2 Low 110% of minimum lot sizes specified in DHR Table MT-1 110% of minimum lot sizes specified in DHR Table MT-2 Source: DHR Manual for On-Site Sewerage Management Systems.
DHR Table MT-1 Single Family Home Minimum Lot Size where served by On-Site Septic Tank Systems.
Slope of Lot
(%) SOIL GROUPING (SEE APPENDIX A*)
12345
MINIMUM LOT SIZE IN SQUARE FEET
0—5 30,000 39,000 48,000 51,000 60,000 5—15 33,000 42,000 51,000 54,000 66,000 15—25 36,000 45,000 54,000 57,000 N/A 25—35 39,000 48,000 57,000 60,000 N/A Source: DHR Manual for On-Site Sewerage Management Systems.
* Appendix A of Ord. No. 99-2 is not set out herein and is available for inspection in the city clerks's office.
DHR Table MT-2 Mobile Home Minimum Lot Size where served by On-Site Septic Tank Systems.
Slope of Lot
(%) SOIL GROUPING (SEE APPENDIX A*)
12345
MINIMUM LOT SIZE IN SQUARE FEET
0—5 10,000 13,000 16,000 17,000 20,000 5—15 11,000 14,000 17,000 18,000 22,000 15—25 12,000 15,000 18,000 19,000 N/A 25—35 13,000 16,000 19,000 20,000 N/A Source: DHR Manual for On-Site Sewerage Management Systems.
* Appendix A of Ord. No. 99-2 is not set out herein and is available for inspection in the city clerks's office.
(k) If the City of Hawkinsville requires a larger lot size than that required by (i) above for homes or by (j) above for mobile homes, the larger lot size shall be used.
(l) Local Governments' at their option may exempt from the requirements of (i) or (j) any lot of record on the date of their adoption of these lot size standards.
(m) No construction may proceed on a building or mobile home to be served by a septic tank unless the Pulaski County Health Department first approves the proposed septic tank installation as meeting the requirements of the DHR Manual and (i), (j), (k), and (l) above.
(n) The Middle Georgia Regional Development Center is responsible for considering, in the regional plan, the cumulative environmental effects of a significant number of septic tank systems being used in close proximity to each other. In so considering the Middle Georgia Regional Development Center shall not approve any local plans that would result in adverse environmental effects on another area. The Middle Georgia Regional Development Center may consult with the Department of Human Resources and Department of Natural Resources for technical assistance as to appropriate densities of lots served by septic tanks in significant recharge areas.
(o) New facilities which handle hazardous materials, of types and in amounts determined by Department of Natural Resources, shall perform their operations on impermeable surfaces having spill and leak collection systems, as prescribed by Department of Natural Resources.
Historia
(Ord. No. 99-2, § 5, 3-22-99)