(a) Generally. Any property within the watershed of the city's water supply shall comply with the following:

(1) Permitted residential uses. Permitted residential uses shall comply with the following:

a. Minimum lot size per zoning district.

b. Minimum natural buffer shall be 100 feet.

c. Minimum setback from natural buffer for all structures, nitrification fields and impervious surfaces shall be 50 feet.

d. No mobile home park or manufactured home park uses allowed within the Watershed Protection District.

e. No multifamily residential uses within the boundaries of the Blue Creek Reservoir.

(2) Permitted agricultural uses. Permitted agricultural uses shall comply with the following:

a. Minimum natural buffer shall be 100 feet.

b. Minimum setback from natural buffer for all structures, nitrification fields and impervious surfaces shall be 75 feet.

c. No chemical treatment (herbicides, pesticides, fertilizers, or paint) allowed in the natural buffer without prior approval of the substance to be used.

(3) Commercial. No commercial structures or uses of any nature allowed within the boundaries of the Blue Creek Reservoir. "Commercial uses" shall be defined as listed as commercial uses in section 102-B-6-1, table of permitted and prohibited uses.

(4) Industrial. No industrial structures or uses of any nature allowed within the boundaries of the Blue Creek Reservoir. "Industrial uses" shall be defined as listed as industrial uses in section 102-B-6-1, table of permitted and prohibited uses.

(5) Permitted recreational uses. Permitted recreational uses shall comply with the following:

a. Minimum natural buffer shall be 50 feet on both sides of any perennial stream as measured from the stream banks and for a distance of 100 feet from the reservoir boundary of Blue Creek Reservoir.

b. Minimum setback from natural buffer for all structures, nitrification fields and impervious surfaces shall be 50 feet on both sides of any perennial stream as measured from the stream banks and for a distance of 100 feet from the reservoir boundary of Blue Creek Reservoir.

c. No chemical treatment (herbicides, pesticides, fertilizers, or paint) allowed in the natural buffer without prior approval of the substance to be used.

(b) Other quality considerations.

(1) It shall be the responsibility of every developer or builder on all construction sites to present required plans and to comply with sediment control requirements promulgated by the city, state and federal governments.

(2) Whenever the zoning district regulations are more restrictive than those contained in this section, the more restrictive provisions shall prevail.

(3) Nonresidential developments may be required to install any or all of, but not limited to, the following devices:

a. Oil-water separators.

b. Grease traps.

c. Presetting basins.

d. No agricultural or recreational activity that does not strictly comply with Georgia Pesticide Act of 1976, Georgia Pesticide Use and Application Act of 1976, and 1982 Ga. Laws, House Bill 1780 (O.C.G.A. § 2-1-4) as amended, or with any and all other laws of the state, will be allowed.

e. No gas-powered boat engines may be operated or used in the water supply or the watershed of the water supply.

f. No gas operated engine may be operated to power a golf cart or personal off-road transport vehicle within the watershed of the water supply.

g. Hunting within the water supply watershed is prohibited.

h. No septic tank or drain field shall be allowed or permitted within the water supply watershed.

(c) Variance. No variance of the restrictions, requirements or prohibitions of this division shall be gained without an application being made to the mayor and city council. The setback requirements shall not be varied and the only variance that may be granted, after due notice and application, shall be as to the buffer size, makeup and uses.

(1) Objective.

a. The existing watershed protection ordinances for the city were developed pursuant to the Rules of Environmental Planning Criteria, chapter 391-3-16, O.C.G.A. § 12-2-8 and provides protection for the quality of the water supply to the Blue Creek Reservoir.

b. The existing ordinance, as written, is without a mechanism for allowing alternate criteria or mitigative measures. This analysis provides mitigative criteria for the development of sites within a water supply watershed (chapter 391-3-16.01).

c. The rationale behind requiring a buffer on each side of a perennial stream within a water supply watershed is to protect the source water by providing a vehicle for the filtering or cleansing of stormwater discharging to a stream. In the event that the regulated buffer is violated, a mechanism for providing an equal capacity of cleansing for the stormwater discharge must be supplied.

d. Chapter 391-3-16.01, section 10 of the environmental planning criteria provides the legal authority for the city to review alternate or mitigative criteria with technical justification for the implementation of alternate of mitigative proposals rests with the property owner. All exceptions to this division must be submitted to the state department of natural resources, through the city for review and comment. This review must be obtained before construction plans can be reviewed for a building permit. The criteria for the development of mitigation plans is outlined in subsection (3)(b) of this section.

(2) Request for variance. If due to physical topographical or other reasons, a site cannot be developed in compliance with this division, for the purpose it was zoned, the owner/developer may request a variance. Application for a variance must develop alternate methods for providing the same level of water quality protection as afforded by natural buffer and impervious surface setback required in this division.

An environmental assessment report shall be prepared in accordance with the guidance documents provided by the state department of natural resources. The report shall explain how the concepts of avoidance, minimization or mitigation have been addressed in the design of the proposed project. The report shall be prepared by one or more individuals having expertise in the following areas: erosion and sediment control, soils science and mechanics, aquatic biology, hydrology and environmental/civil engineering. A statement as to the qualifications of each of the report's authors shall be included as an appendix to the environmental assessment report.

a. Stream buffer variance. The general principal in the preservation of natural stream buffers are as follows:

1. Reserved.

2. Design the site facilities without conflict with natural stream buffers.

3. Relocate the stream so that the site facilities will not conflict with the natural stream buffer requirement. Relocation of a stream requires a mitigation plan approved by the state department of natural resources.

4. A combination of site configuration and stream relocation with approved mitigation plan.

5. In the event reduction of the 100-foot buffer is proposed as a part of a site development plan, equivalent buffer must be provided downstream of the impacted area. An approved mitigation plan must be provided.

6. The least preferred method of developing a site with a perennial stream is to pipe the stream. The initial reaction of the regulatory agencies is to disallow the piping of a stream. Stream piping is normally not allowed because of the adverse effect on cold water microorganisms and the normal small fish population. However, if the steam is enclosed with properly jointed concrete pipe, it will protect the water quality of the stream segment from contaminated runoffs and therefore, piping may be justified.

Piping will require mitigation of the lost stream buffer. Lost or reduced buffer shall be compensated for by providing replacement buffer or the construction of wetlands. Replacement buffer shall be provided at the rate of five times the disturbed buffer area. In the event wetlands are constructed in lieu of replacement buffer, the area of the constructed wetland is two and one-half times the disturbed buffer. Replacement buffer and constructed wetlands shall be set aside as conservation easement as outlined under O.C.G.A. tit. 44, ch. 10 (O.C.G.A. § 44-10-1 et seq.).

b. Impervious surface variance. Mitigation plans for encroachment into the required 175-foot setback of impervious surfaces from a perennial stream shall be developed in accordance with the following:

1. Reserved.

2. All impervious surfaces shall be contoured so that the stormwater runoff is direct to a "first flush" dry retention filter with a subsurface filtration system.

3. The "first flush" of a storm event is of primary importance to water quality.

This term describes the washing action that stormwater has on accumulated pollutants from impervious surfaces. This flushing creates a shock loading of pollutants. Studies have determined that the "first flush" equates to the first one-half inch of rainfall over the impervious area. This runoff carries 90 percent of the pollution load from a storm.

4. Treatment of the first one-half inch of runoff will help minimize the effect of the stormwater on water quality.

5. Surface oil skimming from the "first flush" unit shall be processed through an oil/water separator. Surface discharge from oil/water separators to state waters shall comply with the rules and regulations for water quality control, state department of natural resources chapter 391-3603(5).

(3) Landscape plan requirements. All applications for a variance shall be prepared and shall contain the information as set out in this subsection. A landscape plan is required for the replacement/replanting of buffer vegetation.

a. A landscape plan shall be prepared by a landscape architect registered in the state.

b. The landscape plan check sheet and landscape plan shall contain the following information:

1. Name, address and telephone number of property owner.

2. Name, address, telephone number and seal of landscape architect who prepared the plan.

3. Site location map, north point, scale of drawings.

4. Show all pertinent site features: buildings, walks, drives, underground utilities, water bodies, etc.

5. Show all property lines, distances to bodies of water and/or streams, and the limits of the natural buffer areas.

6. Show calculations on the plan for: total area, buffer area disturbed (in acres and square feet), indicate numbers of canopy and understory trees required by ordinance.

7. Planting key: botanical and common name of all plant materials proposed;

quantity of each species, size of plant material (caliper, height, width);

condition (i.e., balled and bur lapped, container grown, bare root, collected, etc.).

8. Submit three copies of plans for review. One will be returned upon approval.

c. A landscape plan shall include two canopy trees with a minimum trunk caliper of two and one-half inches (at four inches from the ground) for every 1,000 square feet of disturbed buffer area on the site.

e. A landscape plan shall include one understory tree with a minimum trunk caliper of one inch (at four inches from the ground) for every 1,000 square feet of disturbed buffer area on the site.

f. Required trees shall be randomly placed so that the mature canopy covers the buffer area.

g. All disturbed buffer areas shall be 100 percent covered with, deciduous trees, shrubs, and/or ground cover (not requiring mowing).

Historia

La línea de historia que la fuente imprime al final de la sección.

(Ord. No. 23-0605, § 1(Exh. A), 6-5-2023; Ord. No. 24-0916, § 1, 9-16-2024)

Leer este código donde se publica (Municode) La fuente es el código de la ciudad tal como lo publica su editorial o su propio sitio web. Consúltelo allí para ver cambios posteriores.