An attached, two-car enclosed garage is required for each house, condominium, or townhouse.

A carport or garage addition must be designed and constructed of material, along with a gable roof that will match the primary structure. A lean-to and/or metal pole vertical supports are prohibited.

Carport enclosures must be designed and constructed of materials that match the primary structure. Adequate parking must be included as part of the construction plan.

Storage sheds: Sheds shall be maintained in a fashion that prevents the attraction of vermin and does not subtract from the visual appeal of the surrounding neighborhood.

Residential occupancy limitations:

Privacy. Dwelling units, hotel units, rooming units, and dormitory units shall be arranged to provide privacy and be separate from other adjoining spaces.

Minimum room widths. A habitable room, other than a kitchen, shall not be less than ten feet in any plan dimension. Kitchens shall have a clear passageway of not less than four feet between counter fronts and appliances or counter fronts and walls.

Minimum ceiling heights. Habitable spaces, hallways, corridors, laundry areas, bathrooms, toilet rooms and habitable basement areas shall have a clear ceiling height of not less than seven feet.

Exceptions:

In one-family dwellings, beams or girders spaced not less than four feet on center and projecting not more than six inches below the required ceiling height;

Basement rooms in one- and two-family dwellings occupied exclusively for laundry, study or recreation purposes, having a ceiling height of not less than six feet eight inches with not less than six feet four inches of clear height under beams, girders, ducts and similar obstructions; and provided that these rooms are equipped with a hard-wired smoke detector with battery back-up;

Attic or the top habitable floor in a multi-floor dwelling that has rooms occupied exclusively for sleeping, study or similar purposes and having a sloped ceiling over all or part of the room, with a clear ceiling height of at least seven and one-half feet over not less than 50 percent of the required minimum floor area. In calculating the floor area of such rooms, only those portions of the floor area with a clear ceiling height of five feet or more shall be included.