(a) Intent. These criteria are intended to address a building's appearance and requirements for the use of high-quality materials.
(b) Residential standards. The building design regulations of this section apply to all buildings except single-family residential buildings in any zoning district, any buildings located in the Central Business District (CBD), and any buildings located in airports within the General Commercial District (C-2) or the General Industry District (M-1), or both.
(1) Exterior finish materials.
a. Exterior building materials shall be primarily brick, stone, other masonry, glass, wood, true hard coat stucco, or cementitious fiberboard.
Other materials such as vinyl may be used only as accent and trim materials.
b. All exposed foundation walls on all sides of the building shall be faced with brick, stone, or marble.
c. Metal shall be permitted only as metal split seam roofing or as an architectural accent that comprises a maximum of ten percent of the building façade. Acceptable metal materials are limited to architectural metal panels, architectural metal cladding, metal mesh, and perforated metal. Prohibited metal materials include, but are not limited to: stock PEMB metal skins commonly referred to as "R-panel" and sheet metal systems with exposed fasteners, except as required for perforated metals.
(2) Architectural requirements.
a. Each unit shall be required to provide an attached or detached garage a minimum of 11 feet by 25 feet in size of interior clear space.
b. Every unit shall provide a minimum of one architectural projection such as a bay or bow window, front porch, or other architectural feature approved by the zoning official.
(3) The zoning official may waive the regulations for finish materials and architectural requirements for accessory structures if the majority of the accessory structure is shielded by either the principal structure, a privacy fence, vegetative screening, or similar material.
(c) Commercial standards. The building design regulations of this section apply to all buildings except single-family residential buildings in any zoning district and any buildings located in the Central Business District. The general design standards apply to all facades visible from the street, facing streets, and adjacent to or visible from open spaces.
(1) Exterior finish materials.
a. Exterior building materials shall be primarily brick, glass, wood, stucco, stone, textured concrete masonry, or cementitious fiberboard.
b. Materials shall continue around the corner of the building to facades not visible from the public street a minimum depth of 20 feet.
c. Metal shall be permitted only as metal split seam roofing or as an architectural accent that comprises a maximum of ten percent of the building façade. Acceptable metal materials are limited to architectural metal panels, architectural metal cladding, metal mesh, and perforated metal. Prohibited metal materials include, but are not limited to: stock PEMB metal skins commonly referred to as "R-panel" and sheet metal systems with exposed fasteners, except as required for perforated metals.
(2) Fenestration.
a. Fenestration shall be provided for a minimum of 35 percent of the length of all building facades.
b. The length of facade without intervening fenestration or entryway shall not exceed 20 linear feet.
c. Fenestration shall not utilize painted glass, reflective glass, or other similarly treated or opaque windows.
(Ord. No. 2021-01, § 1(Attch.), 2-1-2021; Ord. No. 2020-24, § 1, 4-5-2021; Ord. No.
2021-06, § 1, 5-3-2021; Ord. No. 2021-07, § 1, 5-3-2021; Ord. No. 2021-13, § 1, 6-7-2021; Ord. No. 2023-07, § 1(a)(Exhs. 1—3), 6-5-2023)
Reuniones que se refieren a esta sección
- Jasper City Council, 2 de junio de 2025 (Actas)Se refiere a esta sección en las actas: “Sec. 94-96”, “Sec. 94-96”, “Sec. 94-96”, y 5 más
- Jasper City Council, 7 de octubre de 2024 (Actas)Se refiere a esta sección en las actas: “Sec. 94-96”, “Sec. 94-96”, “Sec. 94-96”
- Jasper Planning Commission, 24 de septiembre de 2024 (Actas)Se refiere a esta sección en las actas: “Sec. 94-96”
- Jasper City Council, 9 de septiembre de 2024 (Actas)Se refiere a esta sección en las actas: “Sec. 94-96”
- Jasper Planning Commission, 27 de agosto de 2024 (Actas)Se refiere a esta sección en las actas: “Sec. 94-96”, “Sec. 94-96”
Leer este código donde se publica (Municode) La fuente es el código de la ciudad tal como lo publica su editorial o su propio sitio web. Consúltelo allí para ver cambios posteriores.